Regency P33 Sunrise™ Gas Fireplace

21

INSTALLATION

Flex Liner

Exhaust

Flue

A maximum

of two certified

joiner kits

may be used

per length.

#948-305

35 ft (11m)

Air Intake

Co-linear DV

Vertical Termination

Cap # 946-529

Co-Linear

Flex

Adapter

with Kit#

946-563

Outer

Pipe

with Kit#

946-563

Inner Pipe

Adapter

with Kit#

946-563

Rigid Pipe Adaptor

# 510-994

Pipe Length

45 Elbow

o

VERTICAL TERMINATION 

 WITH CO-LINEAR FLEX SYSTEM

This appliance is designed to be attached to 
two 3" (76mm) co-linear aluminium 

fl

 ex running 

the full length of the chimney. See the "Venting 
Arrangements - Vertical Terminations" Section for 
minimum and maximum heights.

Required Parts:

Part # 

Description

946-529 

Co-linear DV Vertical 

 Termination 

Cap

948-305 

3" Flex - 35 ft.

946-563 

Co-Axial to Co-Linear Adapter Kit

 

which contains the following: 

 

Co-linear Flex Adapter  

 

 Outer 

Pipe

 Inner 

Pipe 

Adapter 

510-994 Rigid 

Pipe 

Adaptor

46DVA-E45 45

o

 Elbow 

Alternate Approved Caps

46DVA-VC     Vertical Termination Cap
46DVA-VCH  High Wind Cap
46DVAGK      3" Co-linear Adapter with 

fl

 ashing

Masonry chimneys may take various contours which the 

fl

 exible liner will accommodate. However, 

keep the fl exible liner as straight as possible

, avoid unnecessary bending.

The Air Intake pipe must be attached to the inlet air collar of the termination cap.

THE APPLIANCE MUST NOT BE 

CONNECTED TO A CHIMNEY FLUE 

SERVING A SEPARATE SOLID FUEL

BURNING APPLIANCE.

Содержание Sunrise P33S-LP4

Страница 1: ...ght any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 Venture St Delta BC Canada V4G 1H4 918 757a Regency P33 Sunrise Gas Fireplace 01 11 11 Owners Install...

Страница 2: ...th all the warmth and charm of a fire at the flick of a switch ThemodelP33Sunrise hasbeenapprovedbyWarnockHerseyforbothsafetyand efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Страница 3: ... and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassi...

Страница 4: ...e Installation 28 Pilot Adjustment 29 High Elevation 29 S I T Valve Description 29 Gas Pipe Pressure Testing 29 Conversion from NG to LP 30 DC Spark Box Battery Replacement 32 DC Spark Box Replacement 32 Optional Wall Thermostat 33 Optional Remote Control 33 GT remote features 33 Wall Switch 33 Aeration Adjustment 34 Wiring Diagram 34 GT remote wiring Diagram 35 Installing the Optional Fan 36 Opti...

Страница 5: ...0 Btu h 3 51 kW 17 000 Btu h 4 98 kW APPAREIL FONCTIONNANT AU NATURAL GAS CONCU POUR ETRE POELE Pression d allimentation minimum Pression a la tubulure d chappement lev e Pression a la tubulure d chappement basse Grandeur de l injecteur D bit Califorique minimum selon D bit Caliorfique maximum selon l altitude Modéle P33S NG4 é é é é é é APPAREIL FONCTIONNANT AU PROPANE CONCU POUR ETRE POELE Press...

Страница 6: ...ly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspectio...

Страница 7: ...Regency P33 Sunrise Gas Fireplace 7 DIMENSIONS UNIT DIMENSIONS ...

Страница 8: ...lation must conform with local codes or in the absence of local codes withthecurrentCanadianorNational Gas Codes CAN1 B149 or ANSI Z223 1 Installation Codes 2 The appliance when installed must be elec trically grounded in accordance with local codes or in the absence of local codes with the current National Electrical Code ANSI NFPA70 or CSAC22 1 Canadian Electrical Code 3 See general construction...

Страница 9: ...stat e Optional Fan Assembly f Faceplate 10 Wall Mounted ON OFF Switch Use the toggle wall switch supplied with the manual package Use of a decor switch causes higher resistance which is a problem on gas fireplaces 11 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer INSTALLATION CHECKLI...

Страница 10: ...related fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions C F Clearance Dimension Measured From A Front Floor Clearance min 1 25mm Underside of Unit B Sidewall on one side 7 1 2 241mm Side of Unit C Ceiling room and or alcove 30 889mm Top of...

Страница 11: ...CLEARANCES Combustible mantel leg clearances from side of unit as per diagram Due to the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of front facing are shown in the diagram on the right Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board ...

Страница 12: ... allow the finished surface to be flush with the front of the unit Total facing thickness can vary from 1 2 13mm to 1 1 4 32mm thick NOTE Facing material may not protrude beyond unit otherwise the optional accesories will not be able to be mounted to the unit Install Side Nailing Strips and Top Facing Supportbeforeunitisslippedintoposition See Unit Assembly Prior to Installation Section 4 Combusti...

Страница 13: ...Vertical Rise 16 1 2 419mm Rigid 12 3 4 324mm Flex K Corner Wall Length 37 1 2 953mm L Corner Facing Wall Width 53 1 4 1353mm M Framed Chase Ceiling 36 914mm Rigid 32 812mm Flex N Vent Centerline Height 30 762mm Rigid 26 660mm Flex O Gas Connection Height 1 1 2 38mm P Gas Connection Inset 4 102mm Q Gas Connection Width 3 76mm FRAMING DIMENSIONS NOTE If this is an outside corner the minimum distanc...

Страница 14: ...d facing material depth 2 Mount Side Nailing Strip using the 3 supplied screws into the three pre punched screw holes at the front sides of the unit Adjust support to desired facing material thickness UNIT ASSEMBLY PRIOR TO INSTALLATION Top Facing Support Side Nailing Strips folded out VENTING INTRODUCTION The P33 Sunrise uses the balanced flue technology Co Axial system The inner liner vents prod...

Страница 15: ...ed above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public pr...

Страница 16: ...stall the P33S 4 with a maximum run of 2 feet If installing the P33S 4 with a continuous vent length of more than 2 ft 6m to a maximum of 10 ft 3 0m use Kit 946 515 4 ft or 946 516 10 ft or see Rigid Pipe Venting Systems Section for alternate venting arrangements MINIMUM FLEX KIT CENTER LINE MINIMUM RIGID PIPE CENTER LINE AstroCap Flex Kits 1 6 7 8 dia flexible liner kit length 2 4 dia flexible li...

Страница 17: ...Adaptor in conjunction withDuraventDirect Vent SelkirkDirect Temp Ameri Vent Direct venting and Security Secure Vent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI listing of components WARNING Do not combine venting components from different venting systems Exception However useofthetheAstroCapTM and FPI Riser is acceptable with ...

Страница 18: ...A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 N A Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A Extension Pipe 16 Black 46DVA 16AB ...

Страница 19: ...VA HC N A N A N A N A TM 4ST36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all ri...

Страница 20: ...of straight vertical and offset to vertical terminations using one 90o elbow with rigid pipe vent systems for Propane and Natural Gas Unit must be raised 1 Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles Vent must be supported at offsets Note Must use optional rigid pipe adapter when using rigid vent systems Part 510 994 ...

Страница 21: ...Section for minimum and maximum heights Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit which contains the following Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor 46DVA E45 45o Elbow Alternate Approved Caps 46DVA VC Vertical Termination Cap 46DVA VCH High Wind Cap 46DVAGK ...

Страница 22: ...Homes into Masonry Fireplaces The shaded area in the diagrams show the allowable vertical terminations 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet 2 51mm max 8 2 4m Min 30 762mm 30 9 1m Max 30 Horizontal Distance Feet Vertical Height feet ...

Страница 23: ...5o and one 90o elbow two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent systems Refer Rigid Pipe Venting Systems Section Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the terminatio...

Страница 24: ...1 H2 With these options maximum total pipe length is 30 feet with minimum of 11 feet total vertical and maximum 9 feet total horizontal P l e a s e n o t e minimum 1 foot between90o elbows is required A 1 Max 1 Min 3 Max B 2 Max 3 Min 5 Max C 3 Max 5 Min 6 Max D 4 Max 7 Min 7 Max E 5 Max 9 Min 8 Max F 6 Max 11 Min 9 Max Horizontal Venting with Two 2 90o Elbows One 90o elbow Two 45o elbows Option H...

Страница 25: ...2 Max 4 Min 5 Max C 4 Min 3 Max 6 Min 6 Max D 5 Min 4 Max 8 Min 7 Max E 6 Min 5 Max 10 Min 8 Max F 7 Min 6 Max 12 Min 9 Max One 90o elbow Two 45o elbows Option V H V V1 With these options maximum total pipe length is 30 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal Please note minimum 1 foot between 90o elbows is required A 1 Min 4 Max 2 Min B 2 Min 5 Max 3 Min C 3...

Страница 26: ...One 90o elbow Two 45o elbows With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 7 feet total horizontal Please note min 1 foot between 90o elbows is required Option V H H1 V V1 A 2 Min 3 Max 4 Min B 3 Min 4 Max 6 Min C 4 Min 5 Max 7 Min D 5 Min 6 Max 8 Min E 6 Min 7 Max 9 Min F 7 Min 8 Max 10 Min With these options max total pipe length is 30 feet with m...

Страница 27: ... 1 Set the unit in its desired location Check to determine if wall studs or roof rafters are in the way when the venting system is attached If this is the case you may want to adjust the location of the unit Rough in the gas preferably on the right side of the unit and the electrical junction block is on the left side on the left 2 Direct Vent pipe and fittings are designed with special twist lock...

Страница 28: ...system it is highly recommended to apply Mill Pac sealant supplied to every in ner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional 8 Slide the appliance and vent assembly towards the wall carefully inserting the vent pipe into the vent cap assembly It is important that the vent pipe extends into the vent cap suff...

Страница 29: ...ver Note Screw should be snug but do not over tighten Incorrect flame pattern will have small probably yellow flames not coming into proper contact with the rear burner or thermopile or thermocouple HIGH ELEVATION This unit is approved in Canada for altitude to 4500ft CAN CGA 2 17 M91 ForNaturalGas installations above 4500 ft follow current CAN CGA B149 1 PILOT ADJUSTMENT Periodically check the pi...

Страница 30: ...stals or Ceramic Stones Also remove Stainless Steel Panels if installed see page 35 d Remove the 2 screws holding the Burner Assembly to the firebox base Lift out the burner assembly See Diagrams 1 2 6 Unscrew the pilot orifice with the Allen key and replace with the LPG pilot orifice in the kit and replace pilot cap See Diagram 6 7 Remove burner orifice with a 1 2 wrench and discard Use another w...

Страница 31: ... wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten 15 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 16 Re assemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors are appropriate for the gas type Fig 1 Fig 2 Fig 3 Fig 4 LPG Configuration Red o ring visible F...

Страница 32: ...m 2 4 Reinstall battery cover on DC Spark Box 5 Reinstall faceplate refer to steps 5 and 6 of the faceplate installation instructions 1 Shut the power off 2 Remove the faceplate by lifting it up off flush door 3 Remove the screw securing the control assembly plate to the left side of fire box Diagram 1 4 Disconnect the 2 DC spark generator wires from the DC Spark box from location shown in Diagram...

Страница 33: ... thermostat wires to 120V wire Thermostat Wire Table Optional REMOTE CONTROL UsetheRegency RemoteControlKit approved for this unit Use of other systems may void your warranty The remote control kit comes with a hand held transmitter a receiver and a wall mounting plate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very imp...

Страница 34: ... shutter is tightly closed Note Any damage due to carboning resulting from improperly setting the aeration controls is NOT covered under warranty 6 152mm Openings for electrical connections 120 V Power IN Millivolt Wires 4 1 2 114mm 7 16 11mm 2 5 16 59mm Ground Green Neutral Live Black Red Red Minimum Convection Air Temp Switch Ground ON OFF Rotary Speed Control 120V AC 60 Hz Fan To Thermocouple I...

Страница 35: ...ation within 10ft from fireplace 3 Feed the 2ft wire harness through the opening at back of J Box Connect the black red wires to the two wires from the 2 foot SIT Proflame GTMF wire harness TH green TP TH White other wires will not be used 4 Connect the wiring harness to the back of the receiver 5 Install the Receiver in the Low Voltage Junction box supplied with P33S 6 Insert the 4 AA type batter...

Страница 36: ...will touch the hot surfaces Diagram 2 Diagram 1 Diagram 2 Diagram 3 Diagram 4 Fan Control Box Control Mounting Plate Diagram 5 Diagram 7 Diagram 6 9 Secure the fan wires and power cord by attaching one of the adhesive backed wire holder clips Part 910 199 onto the Fire placebase Usethesecondcliptobundleup the wires approximately 4 from the control box Ensure that there is no interference with the ...

Страница 37: ...lack Enamel panels must be inspected for scratches and dimples prior to installation All claims to be recorded at this time Claims for damage after installation will not receive consideration To protect the finish during installation and handling cotton gloves MUST be worn at all times while handling the panels even when removing protective coating Use a hair dryer to remove the protective coating...

Страница 38: ...d glass or stones will not be covered under warranty NOTE When using Ceramic Stones DO NOT cover burner ports that lead to pilot flame Glass Crystals shown on Burner Optional Ceramic Stones shown on Burner There are 2 optional pebble packages to choose from 1 White River Pebbles 2 Natural River Pebbles Spread the pebbles evenly on the exposed base of the firebox Pebbles are NOT to be placed anywhe...

Страница 39: ...swing the door towards the unit diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit See Diagram 2 Use the hook to pull the spring out until you can put the hook into the slot on the bottom door bracket Repeat for 2nd spring See diagram 3 To remove the flush door reverse the above steps...

Страница 40: ... The top of the faceplate has a flange that hooks over the top of the flush door 2 Install the heat deflector on the fire box as shown in Diagrams 2 3 Loosen 3 Phillips head screws already in firebox slide heat deflector on to screws and retighten Diagram 1 Diagram 2 Top of Firebox Heat Deflector Diagram 3 Diagram 4 Diagram 5 Bend Diagram 6 Flange Mounting Frame Heat Deflector Control Shield Facep...

Страница 41: ...ERATING INSTRUCTIONS Diagram 7 Diagram 8 Diagram 9 Faceplate Faceplate Support 6 Hook the flange on the faceplate over the top of the flush door and gently lower the faceplate into place until it rests against the faceplate supports as shown in Diagrams 7 8 ...

Страница 42: ...es a white film may develop on the glass front as part of the curing process The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove Use a non abrasive cleanerandDONOTATTEMPTTOCLEAN THE GLASS WHILE IT IS HOT TheFIRSTFIREinyourheaterispartofthepaint curing process To ensure the paint is properly cured it is recommendedyou burnyourfirep...

Страница 43: ... turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas ...

Страница 44: ...y bird nests or other foreign material 3 Check for evidences of excessive condensation suchaswaterdropletsforming in the inner liner and subsequently dripping outthejoints Continuouscondensationcan cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs too many elbows and exterior portions of the system being exposed to cold weather 4 Inspect joints to verify t...

Страница 45: ...ly See Step 4 in Removing Valve for screw locations 4 Reinstall firebox base 10 Undo the pilot tube from the valve with a 7 16 wrench 11 Undo the quick drop out thermocouple nut on the valve with a 9mm metric wrench 12 Disconnect the 2 DC Spark generator wires from the DC spark box located in front of the valve 13 Undo the gas out flare nut with a 13 16 wrench 14 Undo the gas out flare fitting wit...

Страница 46: ...r W Machine Screw 8 32 x 3 8 904 925 Cap Assy Brushed Stainless 3 4 diameter 14 434 033 Control Mounting Plate 15 434 574 P Valve Assembly P33S NG4 SIT Packaged 434 576 P Valve Assembly P33S LP4 SIT Packaged 16 341 525 Burner Assembly NG LP c w Cap 17 Outerbox Assembly 18 Firebox Assembly 19 433 538 Flush Door Assembly Complete 940 088 P Glass Flush 904 691 U Clip 936 155 Glass Gasket Part Descrip...

Страница 47: ...art be returned to the distributor or agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replace...

Страница 48: ...___________________________________________ Printed in Canada Regency Sunrise is a trademark of FPI Fireplace Products International Ltd Register your Regency online at http www regency fire com Copyright 2010 FPI Fireplace Products International Ltd All rights reserved Regency fireplaces are designed with reliability and simplicity in mind In addition our internal Quality Assurance Team carefully...

Отзывы: