Regency Plateau™ Series Outdoor Gas Fireplace
15
INSTALLATION
10)
Remove two screws to remove valve cover panel.
12)
Attach the label “This unit has been converted to ULPG” near or on top
of the serial # decal.
13)
Replace yellow “NG” label with red “ULPG” label.
11)
Remove Hi/Lo pressure regulator by removing 2 screws as shown below.
Reverse steps to install LP pressure regulator.
HI/LO pressure
regulator
9)
Remove end panel (panel w/ switch) from unit.
Gas connection
@ unit
14)
Remove NG gas line, if installed - replace with LP regulator and quick
connection.
15)
Check all gas connections (both valve train & LP tank) under normal
operating pressure, for leaks, with soapy water.
NOTE:
If soap bubbles, this would indicate a gas leak.
16)
Install LP tank (see LP tank installation in this manual).
17)
Check inlet and outlet pressures.
18)
Check operation of fl ame control.
WARNING:
When connecting the regulator end of the hose to the cylinder valve turn
'POL' connection counter clockwise. If rubber hose type 'POL', tighten
fi rmly by hand—DO NOT OVER TIGHTEN.
Do not use a tool to tighten connection—using a tool may result in damage
to the connection resulting in a gas leak, potentially causing serious risk.
IMPORTANT:
When connecting or replacing gas cylinder, hose assembly, or fi ttings, all
connections must be checked for gas leaks using soapy water solution
and a spray bottle. After completing gas leak test, thoroughly clean off all
remaining soap and water solution with clean water. Some detergents are
corrosive. Contact local authority if gas leaks persist.