WARRANTY

Regency

®

 Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly 

before it leaves our facility.  FPI Fireplace Products International Ltd. is pleased to extend this limited warranty to the  original purchaser of a Regency

®

 Product. This 

warranty is not transferable.

Limited Warranty:  

The combustion chamber is covered for parts and subsidized labour only, against defect in manufacture only, for a period of (5) fi ve years from date of purchase.

The gas valve, burner tube, pilot assembly, fl ame sensor, electrode , control modules, switches and wiring for battery compartment are all covered for (1) one years on parts and (1) 
one year on labor only against defect in manufacture, from date of purchase.

Ceramic logs, spa and garden stones, glass crystals, and tempered glass wind shield carry a (1) one year warranty against manufacturing defect, on parts, with no labor allowance, 
from date of purchase.

Specials fi nishes such as stainless steel components are not covered against environmental damage, including corrosion, misuse, cleaning or handling issues that cause discoloration.  
To receive consideration any damage claim against stainless steel components must be submitted at the time of installation.  Damage from abrasive cleaners is not covered under 
warranty.  Damage reported after installation will not be covered.

Repair/replacement parts purchased by the consumer from FPI after the original coverage has expired on the unit will carry a 90 day warranty, valid with a receipt only. Any item 
shown to be defective will be repaired or replaced at our discretion. No labor coverage is included with these parts.

Conditions:

All installations must be performed by a qualifi ed gas fi tter and installed according to all applicable local and national codes.  Also, all service work must be carried out by a qualifi ed 
gas service person provided by the selling dealer.  It is the responsibility of the installer to ensure that the appliance is fi ring as per rating plate.  Any part or parts of this unit which in 
our judgement show evidence of such defect will be repaired or replaced at Regency

®

's option, through an accredited distributor or agent provided that the defective part be returned 

to the distributor or agent 

Transportation Prepaid,

 if requested. In areas where there is not an approved service agent or the closest approved service agent is situated more than 

thirty (30) kilometres from the installation, Regency is not obliged to arrange warranty repairs and travel and/or additional labour charges will apply.

Porcelain/Enamel - Absolute perfection is neither guaranteed nor commercially possible.  Any chips must be reported and inspected by an authorised dealer within three days of 
installation.  Reported damage after this time will be subject to rejection.

It is the general practice of Regency® to charge for larger, higher priced replacement parts and issue credit once the replaced component has been returned to Regency and 
evaluated fro manufacturer defect.

At all time Regency reserves the right to inspect product in the fi eld which is claimed to be defective.

All claims must be submitted to Regency® by authorised selling dealers.  It is essential that all submitted claims provide all of the necessary information including customer name, 
purchase date, serial #, type of unit, problem, and part or parts requested, without this information the warranty will be invalid.

Exclusions:

This limited Warranty does not extend to or include paint, door or glass gasketing or trim.

Batteries are not covered under warranty policy.

At no time will FPI be liable for any consequential damages which exceed the purchase price of the unit. FPI has no obligation to enhance or modify any unit once manufactured. ie. 
as products evolve, fi eld modifi cations or upgrades will not be performed.

FPI will not be liable for travel costs for service work. 

Installation and environmental problems are not the responsibility of the manufacturer and therefore are not covered under the  terms of this warranty policy.

Any unit which shows signs of neglect or misuse is not covered under the terms of this warranty policy.

The warranty will not extend to any part which has been tampered with or altered in any way, or in our judgment has been subject  to misuse, improper installation, negligence or 
problems caused by environmental or geographical conditions, inadequate ventilation.

Freight damage to stoves and replacement parts is not covered by warranty and is subject to a claim against the freight carrier by the dealer.

FPI will not be liable for acts of God, or acts of terrorism, which cause malfunction of the appliance.

Malfunction | damage of this appliance due to mother nature (wind, rain, snow, etc.) is not covered under the terms of the warranty policy.

Performance problems due to operator error will not be covered by this warranty policy.

Products made or provided by other manufacturers and used in conjunction with the operation of this appliance without prior authorization from FPI, may create a danger and  nullify 
your warranty on this product.

Any alteration to the unit which causes sooting or carboning that results in damage to the interior / exterior facia is not the responsibility of FPI.

* Subsidy according to job scale as predetermined by FPI.

Содержание Plateau PTO30CFT

Страница 1: ...lier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Improper installation adjustment alteration service or maintenance cancauseinjuryorpropertydamage Read the installation operating and maintenanceinstructionsthoroughly before installing or servicing this equipment Installation and service must be performed by ...

Страница 2: ...ries Outdoor Decorative Gas Appliance has been designed to provide you with all the charm of a fire at the flick of a switch The Plateau Series Outdoor Decorative Gas Appliance has been approved by IAPMO for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint...

Страница 3: ... LP Tank installation PTO30cft only 17 LP Tank Installation 18 PTO30IST PTO30CKT ONly 18 LP Tank removal 18 Switch connection 19 Battery Install 19 Table top Installation coffee table unit 20 Table top installation 21 For Island and cocktail units only 21 Glass crystal installation 22 Optional Volcanic stones Installation On Burner 23 Glass surround Installation 24 Riser Installation 25 to convert...

Страница 4: ... NO T DO NO T DO NO T DO NO T DO NO T DO NO T OPERATE THIS APPLIANCE BEFORE READING THE INSTRUCTIONS BOOKLET PLACE ARTICLES ON OR AGAINST THIS APPLIANCE STORE CHEMICALS OR FLAMMABLE MATERIALS SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION OPERATE WITH PANELS COVERS OR GUARDS REMOVED FROM THIS APPLIANCE ENCLOSE THIS APPLIANCE MODIFY THIS APPLIANCE NEAR THIS APPLIANCE DO NO T 90...

Страница 5: ...SIONS UNIT DIMENSIONS COFFEE TABLE 24 610mm 12 13 16 325mm 2 9 16 64mm 2 7 8 73mm 40 5 8 1030mm 1 3 8 35mm 38 965mm 16 11 16 423mm 17 7 8 454mm 19 1 4 490mm 3 5 8 91mm 2 1 16 52mm 4 5KG TANK 4 5KG TANK TOP VIEW SIDE VIEW END VIEW 24 3 4 629mm 30 762mm 8 ...

Страница 6: ... 8 1031mm 3 1 8 79mm Floor to bottom of LP tank 1 25mm 1 5 8 39mm 6 3 16 156mm 20 11 16 525mm Floor level 20lb tank 20lb tank 36 914mm GLASS TO OUTER EDGE BURNER TO OUTER EDGE 62 1575mm 14 1 4 361mm 12 3 16 309mm GLASS TO OUTER EDGE BURNER TO OUTER EDGE 14 1 4 361mm 11 3 4 298mm 36 914mm 9KG TANK 9KG TANK ...

Страница 7: ... 37 15 16 963mm 42 3 16 1072mm 12 7 8 326 mm 49 1 8 1248mm 5 5 16 135mm 12 13 16 325mm 914mm 29 1 4 742mm TOP VIEW SIDE VIEW END VIEW 36 914mm GLASS TO OUTER EDGE BURNER TO OUTER EDGE 62 1575mm 14 1 4 361mm 12 3 16 309mm GLASS TO OUTER EDGE BURNER TO OUTER EDGE 14 1 4 361mm 1 3 4 298mm 36 ...

Страница 8: ...SERVICE TECHNICIAN TO INSPECT THE APPLIANCE AND TO REPLACE ANY PART OFTHE CONTROL SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN SUBMERGED UNDER WATER YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICALBARRIERSISRECOMMEND ED IFTHERE ARE AT RISK INDIVIDUAL INTHE HOUSE T...

Страница 9: ...OUND OPEN AIR SITUATION WITH NATURAL VENTILATION WITHOUT STAGNANT AREAS WHERE GAS LEAK AGE AND PRODUCTS OF COMBUSTION ARE RAPIDLY DISPERSED BY WIND AND NATURAL CONVECTION WARNING DO NOT BUILD FRAME FOR HOUSING CYLINDER UNLESS COMPLI ANCE TO AS 4565 AND AS NZS 5601 1 ARE ASSURED LOCATING YOUR OUTDOOR DECORATIVE GAS APPLIANCE THE COFFEE TABLE REQUIRES THE INSTALLATION OF THE DECORATIVE GLASS SURROUN...

Страница 10: ...nces listed below are Minimum distances unless otherwise stated A major cause of fires is failure to maintain required clearances air space to combustible materials It is of the greatest importance that this decorative gas appliance be installed only in accordance with these instructions Plateau Series Clearance Requirements Clearance Dimension Measured From A Back wall 17 432mm Burner to back wal...

Страница 11: ...itional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code or AS NZS 5601 1 For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper line...

Страница 12: ...ply for operation 0 886 001 Proflame Valve Standard Main On Off Switch or Optional Wall Switch Important The AA batteries in the battery pack operate the burner switch If the batteries become weak they will need to be replaced with quality alka line batteries This unit will not operate without AA batteries Proflame System ...

Страница 13: ... soapy water NOTE If soap bubbles this would indicate a gas leak 5 Reverse steps 1 2 Gas connection unit NOTE a WARNING Cylinder compartment must be kept separate from com bustion chamber Reference to AS NZS 5601 1 b Remote cylinder compartment installation materials ventilation and securing of pipe work fixed and flexible must comply with AS NZS 5601 1 c Refer to AS NZS 5601 1 for flex hoses d Re...

Страница 14: ...erted to LPG 1 908 528 Red LP label 1 911 009 Hi Lo conversion LP For 886 1 911 089 Propane Hose Regulator 48 in 1 919 084 Instruction Sheet Pilot Cap Burner orifice 5 Pull off the pilot cap to expose the pilot orifice Using a 5 32 allen key remove pilot orifice and replace with LP pilot orifice 4 Remove burner orifice with a 1 2 wrench Use another wrench to hold on to the elbow behind the orifice...

Страница 15: ...f soap bubbles this would indicate a gas leak 16 Install LP tank see LP tank installation in this manual 17 Check inlet and outlet pressures 18 Check operation of flame control WARNING When connecting the regulator end of the hose to the cylinder valve turn POL connection counter clockwise If rubber hose type POL tighten firmly by hand DO NOT OVER TIGHTEN Do not use a tool to tighten connection us...

Страница 16: ... instruc tions 1 Lift each corner of the coffee table and remove adjustable rubber foot from each corner 2 Attach the rubber feet removed from Step 1 to the bottom of each leg 3 Install each leg from the bottom up with supplied bolt in the same loca tion rubber foot was removed from Repeat on all four corners Ensure holes all aligned 4 Take the supplied sheet metal screw and fasten each leg with o...

Страница 17: ...ank to tray 5 Connect the LP regulator quick connect to the tank 7 Check all gas connections both valve train LP tank under normal operating pressure for leaks with soapy water NOTE If soap bubbles this would indicate a gas leak NOTE Inspect hoses before each use and replace if evidence of excessive abrasion 919 031 WARNING When using a LP tank a minimum 1 25mm gap at all times between the floor a...

Страница 18: ...tch panel 2 Slide out LP gas tank by pulling from handle on slide out tray 3 Undo butterfly bolt to allow LP tank to be seated on the holder 4 Place LP tank onto slide out try and screw in butterfly bolt to secure tank 5 Push tank in from the bottom DO NOT PUSH IN FROM THE TOP OF THE TANK 6 Connect the LP regulator quick connect to the tank 7 Check all gas connections both valve train propane tank...

Страница 19: ...ch assembly mounted on it from unit 2 Connect 2 wires to the switch 3 Replace panel BATTERY INSTALL SWITCH CONNECTION 3 Install 4 AA batteries and reverse steps Battery compartment 1 Remove left side with switch assembly end panel from unit 2 Pull down battery compartment located below the DFC panel ...

Страница 20: ... D VRIW FORWK DQG D VWDLQOHVV VWHHO FOHDQHU 0RVW VWDLQOHVV VWHHO FOHDQHUV OHDYH D OP UHVLGXH RQ WKH VXUIDFH RI WKH SDQHOV 8VH DQ DPPRQLD EDVHG FOHDQHU LH JODVV FOHDQHU WR UHPRYH WKLV OP EHIRUH DSSO LQJ KHDW WR WKH XQLW Failure to do this will result in burn stains on table top which you will be unable to remove 1RW SURWHFWHG E SURGXFW ZDUUDQW NOTE These instructions apply to both the stainless ste...

Страница 21: ... used to fill the gaps between each tile 6 With 4 corner tiles are in place install center tiles 7 Install 4 smaller inner tiles Install 2 end small inner tiles to com plete tile installation 8 With all tiles installed install inner frame to finish installation NOTE TAKE CARE WHEN HANDLING AND INSTALLING TILES TILES TO FREE FLOAT _ DO NOT GLUE TILES TO TABLE TOP Table Top Components 8 Tiles 6 Tile...

Страница 22: ...age 70 spa stones E33S 1 lb 1 package 70 spa stones NOTE Glass Crystals are available in 1lb and 5lb bags All units come standard with Cobalt Blue glass crystals except HZO42 comes with Copper glass crystals HZI390E HZI390EB HZI540EB PTO30 PTO60 Plateau Series do NOT include glass crystals with units Must purchase separately 1 Ceramic Spa stone package contains 70 stones Recommended use only 40 of...

Страница 23: ... Ivory Tan Glass Crystals For the HZO42 HZO42AUS only Volcanic Stones Slate Grey Glass Crystals For the HZO42 HZO42AUS only OPTIONAL VOLCANIC STONES INSTALLATION ON BURNER Evenly spread the glass crystals and volcanic stones over the burner Ensure the stones do not overlap too much as this will effect the flame pattern IMPORTANT NOTE Only the supplied approved Volcanic Stones are to be used with t...

Страница 24: ...Use supplied spacer tool to determine where the bottom bracket should be placed and secured 4a After the 4 top brackets are installed flip over and place on a soft surface to install the 4 bottom brackets 7 Place assembled glass surround on table top ensure glass is centered on the table top Once in correct position lift up one end apply double sided tape that has been cut to size to the bottom of...

Страница 25: ...the end panels and long side panels place on a clean soft surface 6 Place the island unit frame on top of the riser lining up the screw holes and ensure the drain tube is through the riser drain hole 4 Remove the 4 adjustable rubber feet form the bottom of the island unit and transfer to the bottom of the riser 5 Install the 4 adjustable rubber feet into the bottom of the island riser Seat all the...

Страница 26: ...ce INSTALLATION 5 Install 12 screws in locations shown below to secure island frame to riser base 5 Reinstall LP tank and reconnect or reconnect NG gas line Reinstall panels table top and glass surround and glass crystals to com plete installation ...

Страница 27: ...hen not in use GLASS SURROUND COVER For all units with glass surround installed 1 Place the weather cover over the glass surround when not in use WEATHER COVER For all units 1 Place the weather cover over the entire table when not in use CAUTION Never start the unit with the cover on Let the unit cool before installing the cover Turn off gas supply to unit before installing cover ...

Страница 28: ...ch use 3 Check all hose assemblies for wear Replace if required 4 Check all connections with soap and water clean after as some detergents are corrosive 5 Check all connection fitting hoses prior to each use OPERATING INSTRUCTIONS 1 Readandunderstandtheseinstructionsbefore operating this appliance 2 Check to see that all wiring is correct and enclosed to prevent possible shock 3 Check to ensure th...

Страница 29: ...s of life Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un ...

Страница 30: ...els Use an ammonia based cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove 5 Make a periodic check of burner for proper position and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem call a...

Страница 31: ...Fireplace 31 MAINTENANCE SWITCH REPLACEMENT 1 Remove the end panel side with switch assembly mounted on it from unit 2 Remove 2 wire from the switch 3 Remove 2 screws from switch cover to release switch 4 Replace switch and reverse steps ...

Страница 32: ...ws in locations shown below to remove valve tray 8 Manuover valve assembly up and out 9 Replace gasket if required 10 Replace with new valve assembly 11 Install Hi Lo extension knob removed in step 6 12 Reverse step 6 1 to reinstall 3 Turn off gas supply and remove flex connection at valve 4 Remove orange EV1 wire connected to the gas valve 5 Remove green EV2 wire connected to the gas valve 6 Remo...

Страница 33: ... Disconnect wire harness 3 Replace 4 AA batteries and reverse steps 5 Remove 4 screws to remove DFC box 6 Replace with new DFC box and reverse steps 5 1 2 Removetwoscrewstoremovevalvecoverpanelinlocationsshownbelow 3 Remove two screws to swing down DFC box Wire harness Spark Electrode Ground Battery pack Battery compartment Flame sensor 1 Remove left side with switch assembly end panel from unit 2...

Страница 34: ... frame 6 377 902 Tile set Slate 377 903 Tile set Brown 7 377 080 Inner frame 377 523 Coffee table top Not Shown Part Description 946 775 Fireglass crystals Blk 946 776 Fireglass crystals Copper 946 777 Fireglass crystals Starfire 946 778 Fireglass crystals Colbalt Blue Glass crystals in 5lb bags 2 required 8 376 932 Glass Surround 940 374 P Tempered Glass LG 940 375 P Tempered Glass SM 9 376 027 G...

Страница 35: ...rranty repairs and travel and or additional labour charges will apply Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by an authorised dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of Regency to charge for larger higher priced replacement ...

Страница 36: ...____________________ Date Installed ______________________________________________________ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed abo...

Отзывы: