62
|
P36E-11 Zero Clearance Direct Vent Gas Fireplace
installation
OPTIONAL WALL THERMOSTAT INSTALLATION
This installation must be completed during initial install with the front access
panel removed.
A wall thermostat may be installed if desired.
Recommended: The wall thermostat should be mounted beside the
Remote/Unit Receiver which comes standard with the appliance.
1.
Run wires from thermostat into the unit.
2.
Remove the green wire marked (TH) at the white connector-shown
below. The noted wires will be located near the gas valve.
Disconnect greenTH wire
Green Wires
White Connector
3.
Connect one thermostat lead to female connector, using male spade
connector - see picture below.
CAUTION
Do not wire
Thermostat wires
to 120V wire.
4.
Connect the other thermostat lead to male connector disconnected
from Step1using a female spade connector - see picture below.
When complete turn remote receiver to the ON position.
Unit will now operate using the wall thermostat.
NOTE:
When the remote receiver is set to
ON
position, the remote
control transmitter and all of its features are now disabled.