P36E-11 Zero Clearance Direct Vent Gas Fireplace
|
67
maintenance
5)
Disconnect the inlet gas line.
6)
Disconnect the EV1, EV2, and ground wires
from the valve - as shown below.
7)
Disconnect cable from pressure regulator motor.
8)
Disconnect spark electrode and sensing
electrode wire from DFC board.
REMOVING VALVE
1)
Shut off the gas and electrical supply.
2)
Remove the faceplate, safety screen and glass
door–see detailed instructions in manual.
3)
Remove the logs.
4)
Remove the burner/grate assembly by removing
the two screws and then lift the burner assembly
out.
Diagram 1: Remove the left and right screws
and then lift out the burner/grate assembly.
9)
Remove the rear log stand by removing the 2
screws.
10)
Remove the 10 screws securing the
valve tray assembly in place (Diagram
2) and then lift the entire assembly out
(Diagram 3).
Diagram 2: Rear Log Stand and
Valve Tray Assembly
Screws
Valve Tray Assembly
Rear Log Stand
Screws
12)
Replace with a new a valve tray assembly
and reverse steps 9 - 1.
EV1
EV2
Ground
11)
Lift out valve tray.