Regency P48 Zero Clearance Direct Vent Gas Fireplace
18
INSTALLATION
•
Vent must be supported at offsets.
•
Firestops are required at each floor level and whenever passing through a wall.
•
Maintain clearances to combustibles.
Note: Must use optional flue adapter when using Simpson Dura-Vent pipe (Part # 510-994).
VENTING ARRANGEMENTS - VERTICAL TERMINATIONS
SIMPSON DURA-VENT DIRECT VENT GS SYSTEM
(Propane & Natural Gas)
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations , using two 90
o
elbows,
with Simpson Dura-Vent Direct Vent GS vent systems for Propane and Natural Gas.