Regency P48 Zero Clearance Direct Vent Gas Fireplace
15
INSTALLATION
Horizontal Venting with Two (2) 90
o
Elbows
Option V
H + H1
A)
1' Min. 3' Max.
B)
2' Min. 4' Max.
C)
3' Min. 5' Max.
D)
4' Min. 6' Max.
E)
5' Min. 7' Max.
F)
6' Min. 8' Max.
Horizontal Venting with Two (2) 90
o
Elbows
Option H
V
H + H1
A)
1' Max.
1' Min. 3' Max.
B)
2' Max.
2' Min. 5' Max.
C)
3' Max.
4' Min. 6' Max.
D)
4' Max.
6' Min. 7' Max.
E)
5' Max.
8' Min. 8' Max.
Horizontal Venting with Three (3) 90
o
Elbows
Option H
V
H + H1 + H2
A)
1 Max. 1' Min.
3' Max.
B)
2' Max.
3' Min.
5' Max.
C)
3' Max.
5' Min.
6' Max.
D)
4' Max.
7' Min.
7' Max.
E)
5' Max.
9' Min.
8' Max.
F)
6' Max.
11' Min. 9' Max.
With these options, max.
total pipe length is 30
feet with min. of 11 feet
total vertical and max. 9
feet total horizontal.
Please note min.
1 foot between 90
o
elbows is required.
With these options, max.
total pipe length is 30 feet
with min. of 8 feet total
vertical and max. 8 feet
total horizontal.
Please note min. 1 foot
between 90
o
elbows is
required.
With these options, maxi-
mum total pipe length is 30
feet with minimum of 6 feet
total vertical and maximum
8 feet total horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.
One 90
o
elbow = Two 45
o
elbows.