Vertical Venting
with Two (2) 90° Elbows

Two 45° elbows = One 90° elbow

Option

V

H

V+ V1

Maximum total pipe: length, of 
all sections, must not exceed 
30 feet.  
Total horizontal sections must 
not exceed 8 feet.

Minimum of 1’ pipe section 
between any elbows.
When the total vertical 
exceeds total horizontal by 
2x then the vent restrictor 
must be set to 1.

A)

0’ Min.

2’ Max.

1’ Min.

B)

1’ Min.

4’ Max.

2’ Min.

C)

2’ Min.

5’ Max.

3’ Min.

D)

3’ Min.

6’ Max.

4’ Min.

E)

4’ Min.

7’ Max.

5’ Min.

F)

5’ Min.

8’ Max.

6’ Min.

Vertical Venting
with Three (3) 90° Elbows

Two 45° elbows = One 90° elbow

Option

V

H + H1

V+ V1

Maximum total pipe: length, of 
all sections, must not exceed 
30 feet.  
Total horizontal sections must 
not exceed 8 feet.

Minimum of 1’ pipe section 
between any elbows.
When the total vertical 
exceeds total horizontal by 
3x then the vent restrictor 
must be set to 1.

A)

0’ Min.

2’ Max.

3’ Min.

B)

1’ Min.

2’ Max.

3’ Min.

C)

2’ Min.

3’ Max.

4’ Min.

D)

3’ Min.

4’ Max.

6’ Min.

E)

4’ Min.

5’ Max.

7’ Min.

F)

5’ Min.

6’ Max.

8’ Min.

G)

6’ Min.

7’ Max.

9’ Min.

H)

7’ Min.

8’ Max.

10’ Min.

P40 Gas Fireplace

49

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Содержание P40-LP1

Страница 1: ...26mm Framing Dimensions Description P40 G Framing Width 40 1 2 1029mm H Framing Height 42 1 2 1080mm Hearth I Framing Depth 20 1 16 508mm J Corner Wall Length 50 5 8 1286mm K Corner Facing Wall Width 71 5 8 1524mm L Minimum Height to Combustibles 51 7 8 1318mm M Vent Centerline Height 45 3 8 1153mm N Non Combustible Facing Height 10 1 4 260mm O Gas Connection Height 1 1 2 38mm P Gas Connection Ins...

Страница 2: ...stalled front C Ceiling 39 991mm Top of installed unit D Mantel Depth 13 330mm Maximum Additional on this page E Alcove Width 56 1422mm Sidewall to Sidewall Minimum F Alcove Depth 36 914mm Front to back wall Maximum G Hearth Height 1 1 2 39mm Floor to top of Hearth Hearth must not be higher than base of firebox H Hearth Width 40 1016mm Edge to Edge of Hearth I Hearth Depth 16 406mm Front of Hearth ...

Страница 3: ...Top of Louvers 13 330mm 1 25mm 8 203mm A Standoff B C D Non Combustible Header Non Combustible Facing 14 To Floor Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour 8 Side Wall 7 2 Mantel leg Mantel leg P40 Allowable mantel leg projection 6 1 1 2 Mantel Leg Clearanc...

Страница 4: ...tal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between any elbows Note Must use optional rigid pipe adapter when using Rigid Pipe Part 770 994 Maximum 40 ft 12 2m Minimum 8 9 2 6m Max 10 3m centerline to centerline Minimum 12 305mm Maximum 28 ft 8 5m 0 ...

Страница 5: ...Max 5 Min F 5 Min 8 Max 6 Min Vertical Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 2 Max 3 Min B 1 Min...

Страница 6: ...1 The darker shaded area 6 8 2 0 4 10 12 16 18 14 20 26 28 22 24 30 in the diagram shows allowable venting configurations with the Vent Restrictor on Set 2 Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Minimum of 1 pipe section between any elbows Firestops are required at each floor leve...

Страница 7: ...h Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 9 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 1 Max 1 Min 1 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 M...

Отзывы: