Framing and Finishing

1)

 

Frame the enclosure for the unit with framing material.  Use the 
determined total thickness of facing material (e.g. drywall plus 
ceramic tiles) to adjust the framing depth to allow the fi nished 
surface to be fl ush with the front of the unit. Total facing thickness 
can vary from 1/2” (13mm) to 1-1/4” (32mm) thick.

  

 

Note: Header for the P40 must be non combustible.  

2)

 

For exterior walls, insulate the enclosure to the same degree as 
the rest of the house, apply vapor barrier and drywall, as per local 
installation codes. 

(Do not insulate the fi replace itself.)

3)

 

Ensure that all of the clearances listed below are met.  Combustible 
material may be brought up to the sides of the unit and be covered 
with ceramic tiles, bricks, rock or other suitable combustible 
fi nishing materials. 

Non-combustible facing is required above 

the unit. (See Dimension “N” on page 41)

 

Note: You must maintain proper clearances from the vent to 
combustible materials (See Below).

4)

 

Use metal studs for framing where the minimum clearance from 
the vent to combustible material cannot be maintained.

WARNING

Failure to maintain required clearances is a major cause of 
chimney related fi res.  Installation of this fi replace must comply 
with these clearances.

Clearance:

Dimension

Measured From:

A: Mantel Height

12” (305mm)

Minimum (Additional on this page)

B: Sidewall

8” (203mm)

Side of installed front

C: Ceiling

39” (991mm)

Top of installed unit

D: Mantel Depth

13” (330mm)

Maximum (Additional on this page)

E: Alcove Width

56” (1422mm)

Sidewall to Sidewall (Minimum)

F: Alcove Depth

36” (914mm)

Front to back wall (Maximum)

G: Hearth Height

1-1/2” (39mm)

Floor to top of Hearth. 

(Hearth must 

not be higher than base of fi rebox.)

H: Hearth Width

40” (1016mm)

Edge to Edge of Hearth

I: Hearth Depth

16” (406mm)

Front of Hearth to Wall

Vent Clearances

Clearance Dimension

Horizontal - Top

2-1/2” (64mm)

Horizontal - Side

1-1/2” (38mm)

Horizontal - Bottom

1-1/2” (38mm)

Vertical 

(Flex or Rigid)

1-1/4” (32mm)

P40 Gas Fireplace

I

G

E

B

B

H

A

C

D

F

Hearth Requirements

A 40" (1016mm) wide x 16" (406mm) deep x 1-1/2" (38mm) thick hearth 
is required, unless the unit is raised 4" (102mm).  

All measurements are from the bottom of the unit.  

Therefor the 

bottom of the unit would be fl ush with the top of a non-combustible 
hearth or 4” above the surface of a combustible fl oor.

Floor Mounted Fireplace

Raised Fireplace

Clearance Requirements

Required hearth must be non-combustible. (Page 43)

Required non-combustible facing above unit.  (See Dimension 
“N” on page 41)

10-1/4” Above Fireplace

6”

6”

WARNING: When installing the 

Full Screen Doors

The Full Screen Front  requires 
additional non combustible facing 
and non-combustible framing. 

 

Ensure the 10-1/4" above the 
fi replace, 6" on both sides and 
both the header and side studs 
are non-combustible materials. 
All other clearances, including 
mantel, remain the same.

Full Screen Door Facing Requirements

46

June 2007 Regency Product Specifi cations Book

Gas Fir

eplaces

Gas Fireplaces

Содержание P40-LP1

Страница 1: ...26mm Framing Dimensions Description P40 G Framing Width 40 1 2 1029mm H Framing Height 42 1 2 1080mm Hearth I Framing Depth 20 1 16 508mm J Corner Wall Length 50 5 8 1286mm K Corner Facing Wall Width 71 5 8 1524mm L Minimum Height to Combustibles 51 7 8 1318mm M Vent Centerline Height 45 3 8 1153mm N Non Combustible Facing Height 10 1 4 260mm O Gas Connection Height 1 1 2 38mm P Gas Connection Ins...

Страница 2: ...stalled front C Ceiling 39 991mm Top of installed unit D Mantel Depth 13 330mm Maximum Additional on this page E Alcove Width 56 1422mm Sidewall to Sidewall Minimum F Alcove Depth 36 914mm Front to back wall Maximum G Hearth Height 1 1 2 39mm Floor to top of Hearth Hearth must not be higher than base of firebox H Hearth Width 40 1016mm Edge to Edge of Hearth I Hearth Depth 16 406mm Front of Hearth ...

Страница 3: ...Top of Louvers 13 330mm 1 25mm 8 203mm A Standoff B C D Non Combustible Header Non Combustible Facing 14 To Floor Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour 8 Side Wall 7 2 Mantel leg Mantel leg P40 Allowable mantel leg projection 6 1 1 2 Mantel Leg Clearanc...

Страница 4: ...tal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between any elbows Note Must use optional rigid pipe adapter when using Rigid Pipe Part 770 994 Maximum 40 ft 12 2m Minimum 8 9 2 6m Max 10 3m centerline to centerline Minimum 12 305mm Maximum 28 ft 8 5m 0 ...

Страница 5: ...Max 5 Min F 5 Min 8 Max 6 Min Vertical Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 2 Max 3 Min B 1 Min...

Страница 6: ...1 The darker shaded area 6 8 2 0 4 10 12 16 18 14 20 26 28 22 24 30 in the diagram shows allowable venting configurations with the Vent Restrictor on Set 2 Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Minimum of 1 pipe section between any elbows Firestops are required at each floor leve...

Страница 7: ...h Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 9 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 1 Max 1 Min 1 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 M...

Отзывы: