P40 Direct Vent Gas Fireplace

Model

P40-NG1

P40-LP1

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.5” W.C. (0.87 kPa)

10” W.C. (2.49 kPa)

Manifold Pressure - Low

1.6” W.C. (0.39 kPa)

3.6” W.C. (0.89 kPa)

Orifi ce Size - Front Burner

#44 DMS

#55 DMS

Orifi ce Size - Rear Burner

#35 DMS

#53 DMS

Minimum Input 

13,000 BTU/h (3.81 kW) 

12,000 BTU/h (3.51 kW) 

Maximum Input

45,000 BTU/h (13.19 kW) 

43,000 BTU/h (12.60 kW) 

Vent Sizing

5” Inner / 8” Outer

5” Inner / 8” Outer

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS
Selkirk Direct-Temp

A

B

A

D

C

F

E

Unit Dimensions

Description

P40

A

Front Face Width

40” (1016mm)

B

Rear Firebox Width

33-7/16” (889mm)

C

Front Face Height

34” (864mm)

D

Height w/ Standoff

42-1/2” (1080mm)

E

Unit Depth

20-1/16” (508mm)

F

Height to Vent

35-1/4” (826mm)

Framing Dimensions Description

P40

G

Framing Width

40-1/2” (1029mm)

H

***

Framing Height

***

42-1/2” (1080mm)

***

 + Hearth

I

Framing Depth

20-1/16” (508mm)

J

Corner Wall Length

50-5/8” (1286mm)

K

Corner Facing Wall Width

71-5/8” (1524mm)

L

Minimum Height to Combustibles

51-7/8” (1318mm)

M

Vent Centerline Height

45-3/8” (1153mm)

N

Non-Combustible Facing Height

10-1/4” (260mm)

O

Gas Connection Height

1-1/2” (38mm)

P

Gas Connection Inset

4-3/4” (121mm)

Q

Gas Connection Width

3-1/4” (102mm) 

***

Important:  Framing height requires consideration of the hearth 

depth.   Dimension H = H + the thickness of installed hearth.

G

H

I

K

J

L

P Q

O

M

11" (279mm)

dia. Hole through

wall Vent.

Opening for gas

connection

Top Header
(non-combustible)

Drywall

(or other

facing)

N

Top Header

(non-combustible)

Non-Combustible Facing

P40 Gas Fireplace

Please refer to Page 11 (Exterior Vent Terminations) 

for additional guidelines on vent locations.

Unit requires 

120V to operate.

 See 

“Wiring Diagram,” on page 17, 

for more details. Receptacle is 

included with manual.

45

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Содержание P40-LP1

Страница 1: ...26mm Framing Dimensions Description P40 G Framing Width 40 1 2 1029mm H Framing Height 42 1 2 1080mm Hearth I Framing Depth 20 1 16 508mm J Corner Wall Length 50 5 8 1286mm K Corner Facing Wall Width 71 5 8 1524mm L Minimum Height to Combustibles 51 7 8 1318mm M Vent Centerline Height 45 3 8 1153mm N Non Combustible Facing Height 10 1 4 260mm O Gas Connection Height 1 1 2 38mm P Gas Connection Ins...

Страница 2: ...stalled front C Ceiling 39 991mm Top of installed unit D Mantel Depth 13 330mm Maximum Additional on this page E Alcove Width 56 1422mm Sidewall to Sidewall Minimum F Alcove Depth 36 914mm Front to back wall Maximum G Hearth Height 1 1 2 39mm Floor to top of Hearth Hearth must not be higher than base of firebox H Hearth Width 40 1016mm Edge to Edge of Hearth I Hearth Depth 16 406mm Front of Hearth ...

Страница 3: ...Top of Louvers 13 330mm 1 25mm 8 203mm A Standoff B C D Non Combustible Header Non Combustible Facing 14 To Floor Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour 8 Side Wall 7 2 Mantel leg Mantel leg P40 Allowable mantel leg projection 6 1 1 2 Mantel Leg Clearanc...

Страница 4: ...tal sections must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustible materials Minimum of 1 pipe section between any elbows Note Must use optional rigid pipe adapter when using Rigid Pipe Part 770 994 Maximum 40 ft 12 2m Minimum 8 9 2 6m Max 10 3m centerline to centerline Minimum 12 305mm Maximum 28 ft 8 5m 0 ...

Страница 5: ...Max 5 Min F 5 Min 8 Max 6 Min Vertical Venting with Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H H1 V V1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 8 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 2 Max 3 Min B 1 Min...

Страница 6: ...1 The darker shaded area 6 8 2 0 4 10 12 16 18 14 20 26 28 22 24 30 in the diagram shows allowable venting configurations with the Vent Restrictor on Set 2 Note Must use optional rigid pipe adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Minimum of 1 pipe section between any elbows Firestops are required at each floor leve...

Страница 7: ...h Three 3 90 Elbows Two 45 elbows One 90 elbow Option V H V V1 H H1 Maximum total pipe length of all sections must not exceed 30 feet Total horizontal sections must not exceed 9 feet Minimum of 1 pipe section between any elbows When the total vertical exceeds total horizontal by 3x then the vent restrictor must be set to 1 A 0 Min 1 Max 1 Min 1 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 M...

Отзывы: