P36E-4 Zero Clearance Direct Vent Gas Fireplace
25
Horizontal Venting with Three (3) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
H
H1
V
Horizontal Venting with Two (2) 90
o
Elbows
One 90
o
elbow = Two 45
o
elbows.
Option
V
H + H1
W i t h t h e s e o p t i o n s ,
maximum total pipe length
is 30 feet with minimum
of 6 feet total vertical
and maximum 8 feet total
horizontal.
Please note minimum 1
foot between 90
o
elbows
is required.
A)
0' Min.
2' Max.
B)
1' Min.
3' Max.
C)
2' Min.
4' Max.
D)
3' Min.
5' Max.
E)
4' Min.
6' Max.
F)
5' Min.
7' Max.
G)
6' Min.
8' Max.
Lengths do not include
elbow indicated
Option
V
H
V + V1
H + H1
With these options,
max. total pipe
length is 30 feet
with min. of 12 feet
total vertical and
max. 9 feet total
horizontal.
Please note min. 1
foot between 90
o
elbows is required.
A)
0' Min.
1' Max.
1' Min.
2' Max.
B)
1' Min.
2' Max.
3' Min.
3' Max.
C)
2' Min.
2' Max.
5' Min.
4' Max.
D)
3' Min.
2' Max.
7' Min.
5' Max.
E)
4' Min.
3 Max.
9' Min.
6' Max.
F)
5' Min.
4' Max. 10' Min. 7' Max.
G)
6' Min.
5' Max. 11' Min. 8' Max.
H)
7' Min.
6' Max. 12' Min. 9' Max.
Lengths do not include elbow indicated
INSTALLATION