Regency
®
P36D-1 Zero Clearance Direct Vent Gas Fireplace
55
55
INSTALLATION
REGENCY
®
OPTIONS
BAY TRIM
Attach supplied magnets each to the back of
the top and bottom trim pieces, and attach trim
to the top and bottom of Bay door.
4)
Open the bottom louver. Pull the Burner
ON/OFF control box from inside the bottom
of the fi replace and position the slots in the
bracket over the 2 screws on the left side
of the bottom louver. Push down to lock into
place. Tighten the screws.
Burner ON/OFF
control box
Screws on louver
bracket
BAY DOOR
The Bay louvers MUST be used
with the Bay glass option.
The optional Bay door is an overlay on the
fl ush front.
The standard fl ush door and glass
must remain on the unit.
1)
Slide the Bay Defl ector into the 2 Bay
Defl ector brackets in the top of the unit.
2)
Hook the top of the bay door over the fl ush
door fl ange and swing the bottom against
the bottom fl ange of the fl ush door.
3)
Secure to the fl ush door bottom bracket with
2 screws provided.
BAY LOUVERS
1)
Install top louver by sliding the two bracket
clips into the brackets located on top of the
bay door. See below. The fi tted louver leaves
a small gap between faceplate bottom and
louver top.
2)
Install bottom louver by sliding the two
bracket clips into the brackets located
underneath the bay door. Secure with 1
screw into each Bottom Louver Mounting
Bracket as per diagram below. Use the
bottom hole in the bracket.
3)
Slide the valve extension knobs onto the
valve knobs. Match the correct ext. knob
with the valve knob.
Note: If any maintenance etc. must be
done in the fi rebox, fi rst remove the
Bay louvers and door.