background image

Regency

®

 P36D-1 Zero Clearance Direct Vent Gas Fireplace

39

INSTALLATION

27)

  Run the other end of the ground wire 

and DC spark generator wires through 
the bushing on the heat shield. 

29)

  Plug the DC spark generator wires to the 

DC Sparker.

30)

  Connect the  ground wire to the DC Sparker 

mounting bracket.

Heat Shield

33)

  Find a location which is not too hot and 

is easy to reach for changing the battery. 

 

Note: It should be kept away from the 
chain.

34)

  Tie up the loose wires with the wire clip.

Chain

35)  

Check for gas leaks.

36) 

Check inlet and outlet pressures.

37) 

Check operation of fl ame control.

38) 

Check for proper fl ame appearance and 
glow on logs. 

NOTE:   The battery in the DC Sparker  

 

Box will need to be replaced an- 

 nually.

25)

  Locate the ground lug. 

26)

  Connect one end of the supplied green 

ground wire to the lug with the nut and 
washer from the kit. 

Ground 

wire from 

kit

28)

  Install the 1/2" bushing to the heat 

shield.

32)

  Mount the heat shield to the DC Sparker. 

Secure into place with the velcro, which is 
provided in the kit.

For P36D-1 / P36-4 Only:

25a)

 By the receptical box, left of the unit.

For U32-5 Only:

25b)

 Located on the left side of the unit.

31)

 

Install the supplied battery into the DC 
Sparker Box by opening the battery 
compartment.

Battery

Compartment 

Содержание P36D-1

Страница 1: ...ollowed exactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation and service must be performed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY What to do if you smell gas Do not try to light ...

Страница 2: ...designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model P36D 1 has been approved by Warnock Hersey for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many featu...

Страница 3: ...n must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada ThisFPI Mobile ManufacturedHomeListedappliancecome...

Страница 4: ... 47 Optional Fan Installation 49 Optional Fan Removal 49 SAFETY LABEL Copy of Safety Decal for P36D 1 6 REQUIREMENTS MA Code CO Detector 7 Unit Dimensions 8 Hampton Faceplate Dimensions 8 Before You Start 9 Important Message 10 General Safety Information 10 Installation Checklist 10 Locating Your Gas Fireplace 11 Manufactured Mobile Home Additional Requirements 11 Heatwave Duct System Optional 11 ...

Страница 5: ... or Brass 52 Louvers Trim 52 Log Replacement 52 Thermopile Thermocouple 52 Glass Gasket 52 Door Glass 52 Flush Glass Replacement 52 Bay Glass Replacement 52 Removing Valve 53 Installing Valve 53 Flush Trim 54 Flush Louvers 54 Bay Door 55 Bay Trim 55 Bay Louvers 55 Full Screen door Installation 56 Tripoli screen door 58 Hampton Cast Faceplate 61 Hampton Cast Grills 62 PARTS LIST Main Assembly 63 Bu...

Страница 6: ... 510 930 Option HeatWave Kit 946 556 Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique Cet appareil peut être installé dans une maison préfabriquée ou mobile É U seulement installée à demeure si les règlements locaux le permettent Voir la notice de l utilisateur pour plus de renseignements Cet appareil ne peut pas être utilisé avec d autres gaz sauf s...

Страница 7: ...rade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upo...

Страница 8: ... Direct Vent Gas Fireplace INSTALLATION 36 914mm 33 838mm 36 914mm 30 1 2 775mm 37 940mm 17 1 8 435mm 32 1 2 826mm 37 940mm UNIT DIMENSIONS 43 1 4 1099mm 32 1 4 819mm 29 1 2 749mm 31 1 4 794mm 1 1 4 32mm HAMPTON FACEPLATE DIMENSIONS ...

Страница 9: ... APPLIANCE BE KEPT CLEAN DUE TO HIGH TEMPERATURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES WARNING FAILURE TO INSTALL THIS APPLIANCE CORRECTLY WILL VOID YOUR WARRANTY AND MAY CAUSE A SERIOUS HOUSE FIRE YOUNG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO AC...

Страница 10: ... cutting holes for termination 11 Under no circumstances should this appliance be modified Parts that have to be removed for servicing should be replaced prior to operating this appliance 12 Installation and any repairs to this appliance should be done by a qualified service person A professional service person should be called Emissions from burning wood or gas could contain chemicals known to th...

Страница 11: ...nstallationswhenusedwithaListedMillivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P36D 1 Direct Vent Gas Fireplace is approvedforalcoveinstallations whichmeet the clearances listed on the next page 7 Werecommendthatyouplanyourinstallation on paper using exact measurements for clearances and floor protection before actually installing this appl...

Страница 12: ...ordance with these instructions Clearance to Combustibles from Back 0 0mm Side 0 0mm Floor 0 0mm NOTE The minimum floor clearance must be maintained from the top surface of the carpeting tile etc Minimum Clearance from Top of Unit to Ceiling from top of unit 32 1016mm Side Wall Clearances Bay or Flush Front 6 152mm Hampton Cast Faceplate 6 152mm Full Screen Doors 6 152mm Measured from Surround or ...

Страница 13: ...Regency P36D 1 Zero Clearance Direct Vent Gas Fireplace 13 INSTALLATION Clearances for Bay Front Flush Front Full Screen Doors REGENCY CLEARANCES HAMPTON CLEARANCES TRIPOLI ARCH DOOR CLEARANCES ...

Страница 14: ... Standoff 6 Standoff Because of the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of unit are shown in Diagrams 1 2 REGENCY COMBUSTIBLE MANTEL CLEARANCES These drawings are to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel an...

Страница 15: ...s from top of unit are shown in the diagram below Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board These drawings are to scale at 1 6 one inch 6 inches Mantel can be installed anywhere in shaded area or higher using the above scale Note Ensure the paint that is used on the mantel and the facing is heat resis...

Страница 16: ...tel and the facing is heat resistant or the paint may discolour HAMPTON COMBUSTIBLE MANTEL CLEARANCES Mantel Clearances with Hampton Cast Faceplate 7 Because of the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of unit are shown in the diagram below Note A non combustible mantel may be installed at a lower height if the framing is made ...

Страница 17: ...ximum 1 1 2 projection at 2 minimum clearance HAMPTON TRIM MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram 5 2 6 Min Mantel leg Mantel leg P36D Fireplace Allowable mantel leg projection 3 1 1 2 Hampton Cast Faceplate Measure from edge of Faceplate Maximum 1 1 2 projection at 2 minimum clearance Hampton Cast Faceplate Width 43 1 4 ...

Страница 18: ... to the ceiling 2 Frame in the enclosure for the unit with framing material The framed opening is 37 1 4 high x 36 1 4 wide x 17 3 8 deep 946mmhighx921mmwidex441mmdeep FRAMING AND FINISHING Note 40 1 2 1029mm is the minimum height for both flex termination or Simpson Dura Vent venting Note Theunitdoesnothavetobecompletely enclosedinachase The clearanceon topoftheunitis0 tothestandoffsso combustibl...

Страница 19: ...h Door a non combustible material 12 305mm above the unit and 6 153mm on each side must be used See diagram 2 For complete framing dimensions see page 57 in this manual The Tripoli Arch Door also requires steel stud framing above and on each side of the unit see diagram 2 TRIPOLI ARCH DOOR FRAMING NOTE Diagram 2 ...

Страница 20: ...hecombustionchambertherebyeliminatingthe need to use heated room air for combustion and losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Eachdirectventgasappliancemust...

Страница 21: ...ine extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on...

Страница 22: ...Cap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 1 6 7 8 dia flexible liner 10 ft length 2 4 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 If longer runs are needed the FPI Direct V...

Страница 23: ...N A N A Adjustable Length 3 10 Galvanized N A N A N A 4DAL N A TC 4DLT Adjustable Length 3 10 Black N A N A N A 4DALB N A TC 4DLTB Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4...

Страница 24: ...rizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK N A Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK N A Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optiona...

Страница 25: ...hes The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as well as Simpson Dura Vent Direct Vent American Metal Products Security Secure Vent AmeriVent Direct Vent AstroCapTM is the proprietary trademark of FPI Fireplace Products International Ltd Dura Vent and Direct Vent are registered and or proprietary trademarks of Simpson Dura Vent Co Inc ...

Страница 26: ... 6 7 8 inner diameter Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall NOTE If you are installing the P36D 1 into an FPI cabinet Mantel Kit use the minimum horizontal vent height centre line of 40 1 2 Remember to include the mantel base 3 in height in your calculations and to maintain t...

Страница 27: ...in clearances to combustibles Note Must use optional rigid pipe adaptor when using rigid vent systems Part 510 994 VENTING ARRANGEMENTS VERTICAL TERMINATION RIGID PIPE SYSTEM Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbow with rigid pipe vent systems for Propane and Natural Gas ...

Страница 28: ...the diagram 1 The shaded area in the diagram 1 shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas Maximum two 45o elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles Diagram 1 ...

Страница 29: ...tal Please note minimum 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated Option V H V V1 H H1 A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 Max D 3 Min 2 Max 7 Min 5 Max E 4 Min 3 Max 9 Min 6 Max F 5 Min 4 Max 10 Min 7 Max G 6 Min 5 Max 11 Min 8 Max H 7 Min 6 Max 12 Min 9 Max With these options max total pipe leng...

Страница 30: ...vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated Option V H H1 V V1 A 0 Min 2 Max 2 Min B 1 Min 2 Max 3 Min C 2 Min 3 Max 4 Min D 3 Min 4 Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6 Min 7 Max 9 Min H 7 Min 8 Max 10 Min With these options max total pipe length is 30 feet with ...

Страница 31: ... bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 510 994 Rigid Pipe Adaptor FPICabinetand orFlatWallMantlesmay be used in these applicat...

Страница 32: ...ENTING ARRANGEMENT VERTICAL TERMINATIONS CO LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL MANUFACTURED HOMES The shaded area in the diagrams show the allowable vertical terminations 8 Min 40 1 2 30 Max 30 Horizontal Distance Feet Vertical Height feet 2 max ...

Страница 33: ...ent is only for use in above grade terminations NOTE For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every in ner pipe connection Failure to do so may result in drafting or performance issues not covered under warranty Silicone red RTV is optional Note With Dura Vent the minimum h e i g h t i s achieved by i ...

Страница 34: ...exit and mark the location wheretheventwillpenetratetheceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previously drilledintheceiling andmarkthespotwhere the vent will penetrate the roof Determine if ceilingjoists roofraftersorotherframingwill obstruct the venting system You may wish to relocate the appliance or to offset asshown in Diagram 2 to avoid cuttin...

Страница 35: ...RECT VENT SYSTEM FLEX INSTALLATION PROCEDURES 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall accordingly Cut a 10 254mm hole in the wall inside dimension Note A 1 1 2 38mm clearance around the liner must be maintained except that only ...

Страница 36: ...all probably yellow flames not coming into proper contact with the rear burner or thermopile or thermocouple alwaysbesttoconsultwithyourlocalauthorities and the CAN CGA B149 installation code For USA installations follow local codes and or the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be e...

Страница 37: ...ws holding the Burner Assembly to the firebox base Push the Burner Assembly to the left and lift out DC Sparker Kit Contains Qty Part Description 1 820 475 Bracket DC Sparker 1 820 476 Bracket DC Sparker 1 904 153 Washer 8 External Star 1 904 330 Nut 8 32 Hex 2 904 531 Bushing Split Plastic 0 500 in 1 904 543 Screw 8 32 x 3 4 Pan Head 2 904 553 Screw 8 x 1 2 Type B Black Oxide 1 910 073 Spark Gene...

Страница 38: ...tor and connect it to the DC Sparker Piezo Ignitor Ignitor Wire Piezo Ignitor Ignitor Wire DC Sparker 18 Reverse steps 6 1 Fig 1 11 Remove the black protection cap by hand from the hi low knob Fig 1 Fig 2 14 Flip the screw Fig 3 Fig 4 Fig 3 15 Using the Allen wrench as shown in Fig 4 rotate the screw clockwise until snug do not overtighten 12 Insert a 5 32 or 4mm Allen wrench into the hexagonal ke...

Страница 39: ...let and outlet pressures 37 Check operation of flame control 38 Check for proper flame appearance and glow on logs NOTE The battery in the DC Sparker Box will need to be replaced an nually 25 Locate the ground lug 26 Connect one end of the supplied green ground wire to the lug with the nut and washer from the kit Ground wire from kit 28 Install the 1 2 bushing to the heat shield 32 Mount the heat ...

Страница 40: ... by carefully slipping it between the back wall of the firebox and the rear log bracket 3 Put the side panels in next Slide them in from the front and push them flat up against the wall Be very careful not to scratch them on the firebox hardware 4 Install the 2 brick retaining clips one on each side Note If the bottom brick panel must be removed Remove the Rear Log Stand then remove the Burner Tra...

Страница 41: ... log kit Part 780 930 contains the following pieces a 02 75 Rear Log b 02 55 Middle Left Log c 02 50 Front Left Log d 02 53 Center Left Log e 02 51 Front Bottom Log f 02 54 Center Right Log g 02 52 Middle Right Log h 902 156 Embers i 902 179 Vermiculite j 946 669 Platinum Embers supplied with packaged manual NOTE If you will be installing the optional Brick Panels P36D P90 only install the Brick P...

Страница 42: ...d rest the log on the cutout on Log 02 53 Cutouts 5th Grate Tab 02 54 0 2 5 3 02 51 6 Position Log 02 54 across the cutouts in Logs 02 51 and 02 53 The notch in the bottom right end fitting against the 5th grate tab 5 Position Log 02 53 across the cutouts in Logs 02 75 and 02 51 with the notch on the left side of the log fitting into the 2nd grate tab Cutouts 2nd Grate Tab 02 53 02 75 02 51 02 51 ...

Страница 43: ... 52 02 51 02 54 02 52 02 54 8 Place Log 02 52 between Logs 02 51 and 02 75 and on the indentation on Log 02 54 The bottom right end sits behind the rear grate tab Front Brackets Notch 02 50 02 53 02 50 02 55 02 53 9 Sit Log 02 50 on the front left side of the burner Push the back of the log against the 2 front brackets with the notch on the bottom of the log fitting into the first grate tab ...

Страница 44: ...and around the embers Avoid stacking platinum embers Platinum embers may be placed over burner ports 11 Test fire to ensure proper light off make sure flame flows smoothly from one end of burner to the other If there is any flame hesitation check that area for any blockage of the burner ports Do not block the burner ports in this area adjacent to the Log 02 54 02 51 02 54 IMPORTANT When placing Em...

Страница 45: ...m 2 The standard flush door comes with a black frame To install the frame simply hook the top door flange onto the top of the unit and swing the door towards the unit see diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit see Diagram 2 Diagram 1 STANDARD FLUSH DOOR To remove the flush...

Страница 46: ... warranty The remote control kit comes with a hand held transmitter areceiverandawallmountingplate 1 Choose a convenient location on the wall to install the receiver and the receptacle box protection from extreme heat is very important Run wires from the fireplace to thatlocation UsetheThermostatWireTable 2 Connect the two wires to the gas valve See diagram below CAUTION Do not connect millivolt r...

Страница 47: ...will continue to operate However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off under any circumstances NOTE Even if the fan is not purchased with the unit it is still a good idea to bring power to the receptacle box provided with the unit in case the fan is installed at a later date CAUTION Label all wires prior to disconnection when servic ing c...

Страница 48: ...y P36D 1 Zero Clearance Direct Vent Gas Fireplace INSTALLATION For PROPANE Units and Units Equipped with DC Spark Boxes For installation of the DC Spark Box refer to the LP Conversion instructions in this manual ...

Страница 49: ...approximately4 fromthecontrolbox Ensure that there is no interference with the wires when the louver is closed and that no wire will touch the hot metal surfaces or sharp edges 13 Plug the fan power cord into the rear end of the receptacle box to provide the maximum clearance from the louvers OPTIONAL FAN REMOVAL 1 Shut the power off 2 Reverse the above instructions Note Thebearingsarelubricatedfo...

Страница 50: ... of the curing process The glass should be cleaned or the film will bake on and become very difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot AERATION ADJUSTMENT The air shutter can be adjusted by moving the adjusting wire up or down The wire is accessed throughthebottomlouveropening Opentheair shutter for a blue flame or close for a yellower flame The burner...

Страница 51: ...rner tray is positioned directly under the burnertube s andlogsandismadeofadifferent gauge material from the rest of the firebox and body Therefore thevaryingthicknessesofsteel will expand and contract at slightly different rates which can cause ticking and cracking sounds You should also be aware that as there are temperature changes within the unit these sounds will likely re occur Again this is...

Страница 52: ...e position of these logs must be as shown in the diagrams under Log Installation Note Improper positioning of logs may create carbon build up and will severely alter the unit s performance which is not covered under warranty THERMOPILE THERMOCOUPLE 1 Open the bottom louvers 2 Loosenthethermocoupleorthermopilewith a 7 16 wrench 3 Disconnect thermocouple by loosening nut from the valve with a 9mm wr...

Страница 53: ...ect the appliance performance 9 Reinstall the 10 hold down screws 10 Hook up the 2 TP and 2 TH wires to the appropriate connections on the valve 11 Reinstall the bottom brick panel and the front log stand 12 Install Burner grate assembly 13 Hook up the gas line and check for gas leaks with a soap and water solution or a gas leak detector Do not use open flame for leak testing 14 Fire up the unit t...

Страница 54: ...om louver Pull the Burner ON OFF control box from inside the bottom of the fireplace and position the slots in the bracket over the 2 screws on the left side of the bottom louver Push down to lock into place Tighten the screws Burner ON OFF control box attached to bottom flush louver Screws on louver bracket Burner ON OFF control box FLUSH TRIM Attach the round magnets to the back of the top trim ...

Страница 55: ...unit 1 Slide the Bay Deflector into the 2 Bay Deflector brackets in the top of the unit 2 Hook the top of the bay door over the flush door flange and swing the bottom against the bottom flange of the flush door 3 Secure to the flush door bottom bracket with 2 screws provided BAY LOUVERS 1 Install top louver by sliding the two bracket clips into the brackets located on top of the baydoor Seebelow T...

Страница 56: ... the inner cut outs to secure the base of the Frame using the 2 x Hex Head Drill Point Screws provided Backside of Full Screen Door Frame Shown Inside Top of Outer Frame Hinge Bracket Inner Hinge Bracket Screw 2 Full Screen Door Frame Installation a Before attaching the Full Screen Door Frame to the unit loosen the left and right side 8 Philips Head Screws located on the inside top of the outer fr...

Страница 57: ...Hinge Location 6 Slide the Top Grill into the louver brackets located on the inside top of the firebox Push in place Top Grill 8 Close screen doors 7 Install the Left and Right Side Screen Doors in the fully open position by placing over top of the hinges on the Full Screen Door Frame NOTE Failure to install the doors in the fully open position could result in paint damage to the surface of the do...

Страница 58: ...m 1 Option 1 Fireplace with 1 1 2 38mm Facing Material INSTALLATION NOTE The hearth material must be brought past the Tripoli frame all the way to the unit face so there will be no gap between the face and the actual fireplace D is Minimum height to combustible materials including the Minimum 2 51mm Top clearance to the Horizontal Vent OPTIONS FRAMING DIMENSIONS P36 P36D A B C D A B C D 1 36 1 4 9...

Страница 59: ...d bracket as indicated refer to Diagram 2 3 Install On Off switch refer to Diagram 3 4 Place bracket under the Flange Secure with 2 screws as indicated in Diagram 4 Diagram 2 Diagram 3 5 Loosen the 3 x 8 Phillips Head Screws located on the inside top of the outer frame of the appliance refer to Diagram 5 Remove bracket Remove both screws On Off Switch Control Mounting Bracket 3 x 8 Phillips Diagra...

Страница 60: ...ith the correspond hole on the Top Support Frame then secure with 1 screw b Repeat step on the other side 10 Change in Logo Replace existing logo with Regency logo a Mount Side Support Frame to unit as shown in Diagram 6 then secure with 2 screws on each side 7 Side Support Frame b Repeat step on the other side 6 Install Top Support Frame Slide in the Top Support Frame using the slots as a guide S...

Страница 61: ... Secure with screws tighten loosely Secure top of faceplate with screw 4 Repeat step 3 for the right side faceplate Secure bottom of faceplate with screw 5 Slide top piece of faceplate into side faceplates by fitting mounting plates into brackets 6 Push in both side faceplate pieces and completely tighten screws 7 Re install top louver and grill 8 Close bottom louver and grill Side piece Faceplate...

Страница 62: ...nstall new hinge brackets using the same 2 screws removed in step 3 5 Install hinge to bracket then secure with screw New hinge bracket Left side shown 6 Place something underneath bottom grill to prevent scratching 7 Line up hinge holes in bottom grill holes 8 Place screws half way in do not secure completely Hinge 9 Place bracket over screws then push to the side against faceplate to lock in pla...

Страница 63: ...ight 34 Brick Panel Bottom 35 Thermodisc Bracket 432 967 Burner ON OFF Switch Assy 38 910 241 Switch Burner ON OFF 3 way 910 899 Wire Harness Valve to Burner 432 917 Fan Speed Control Assy 120 Volts Optional 42 910 331 P Fan Motor 432 966 Fan Switch Assy 120 Volts Optional 43 910 813 Power Cord 120 Volts 46 910 330 Fan Speed Control Switch 47 904 586 Knob Speed Control 48 910 199 Wire Holder Clip ...

Страница 64: ...opane 56 Valve Tray NG LP 57 910 478 Valve S I T Natural Gas Propane 58 Valve Bracket 65 Pilot Bracket 66 910 038 Pilot Assy S I T 3 Flame NG 910 039 Pilot Assy S I T 3 Flame LP 67 Pilot Holder 68 W840470 Pilot Assembly Gasket 904 240 Orifice 37 Natural Gas 904 390 Orifice 52 Propane 936 170 Orifice Gasket 69 Firebox Base 75 Deflector Left 76 Deflector Right 79 791 535 Burner Assy NG LP 82 511 030...

Страница 65: ...12 Bay Front Trim Top Bottom 780 934 Bay Front Trim Set Gold 113 Bay Front Trim Gold Bottom 114 Bay Front Trim Gold Top 510 988 Bay Louvers Black 510 993 Bay Louvers Steel Black 510 990 Bay Louvers Gold Black 510 992 Bay Louvers Brass Black 115 Bay Louver Assy Top 116 Bay Louver Assy Btm 117 904 196 Magnet 1 round 119 780 025 Bay Door Baffle 120 Glass Retainer Bracket 160 948 216 Regency Logo Plat...

Страница 66: ...22 Flush Louvers Set Black 510 923 Flush Louvers Set Steel Black 138 Flush Louver Assy Top 139 Flush Louver Assy Btm 510 934 Flush Glass Trim Set Brass 510 947 Flush Glass Trim Set Steel 152 Flush Glass Trim 904 196 Magnet 510 932 Flush Glass Trim Set Gold 150 Flush Glass Trim 904 196 Magnet 510 986 Finishing Trim Set Black 157 Finishing Trim Left 158 Finishing Trim Top 159 Finishing Trim Right 16...

Страница 67: ...RILL ASSEMBLY Part Description 513 971 Cast Faceplate Set 201 Cast Faceplate Right 202 Cast Faceplate Top 203 Cast Faceplate Left 513 981 Cast Grills Set 204 Top Grill 205 Bottom Grill Not available as a replacement part Last digit of part number represents colour 1 Black Metallic 5 Enamel Brown ...

Страница 68: ...68 Regency P36D 1 Zero Clearance Direct Vent Gas Fireplace NOTES ...

Страница 69: ...Regency P36D 1 Zero Clearance Direct Vent Gas Fireplace 69 NOTES ...

Страница 70: ...70 Regency P36D 1 Zero Clearance Direct Vent Gas Fireplace NOTES ...

Страница 71: ...r agent Transportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the...

Страница 72: ..._ Serial No __________________________________________________________ Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related products Printed in Canada Ha...