34
P33CE Direct Vent Gas Fireplace
INSTALLATION
CONVERSION FROM NG TO LP
For P33CE Using SIT 886 NOVA Gas Valve
Each Kit contains one LPG
Conversion Kit
LPG Conversion Kit Contains:
Qty. Part #
Description
1
904-163
Burner Orifice #54
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1
904-529
5/32" Allen Key
1 910-101
LPG Injector
(Pilot
Orifice)
1
911-009
Hi/Lo Conversion LP
1 919-139
Instruction
Sheet
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT
DO NOT DO THIS CONVERSION!!
Installation of the LPG
Conversion Kit:
1.
Shut off the gas supply.
2.
Remove the glass door.
a)
Release the two hooks from the
bottom of the glass door.
b)
Swing the door out 45 degrees from
the bottom - then lift up and out.
R
th 2
h B
3.
Remove logs and brick panels if
installed.
4.
Remove the 2 screws holding the Burner
Assembly to the firebox base. Push the
Burner Assembly to the left and lift out.
6.
Unscrew the pilot orifice with the Allen
key and replace with the LPG pilot orifice
in the kit and replace pilot cap.
7.
Remove burner orifice with a 1/2"
wrench and discard. Use another wrench
to hold on to the elbow behind
the orifice.
8.
Reinstall new burner orifice LPG
stamped #54 and tighten.
9.
Remove regulator and discard. Install the
Hi/Lo pressure regulator onto the valve
with 2 screws as shown below.
10.
Attach the label “This unit has been
converted to LPG” near or on top of the
serial # decal.
11.
Replace yellow “NG” label with red “LPG”
label.
12.
Reverse step 3 - 1
13.
Check for gas leaks.
14.
Check inlet and outlet pressures.
15.
Check operation of flame control.
5.
Undo clip and remove pilot cap to
expose pilot orifice.
Clip
Pilot Cap
Installer Notice:
These instructions must be
left with the appliance.