Regency® P33CE Zero Clearance Direct Vent Gas Fireplace
MAINTENANCE
REMOVING VALVE
1.
Shut off the gas supply.
2.
Open
the
fl ush door (see instructions in this manual) and remove
the door.
3.
Remove the burner/grate assembly by removing the two screws
and then lift the burner assembly out.
Diagram 1: Remove the left and right screws and then lift out the
burner/grate assembly.
4.
Remove the rear log stand by removing the 2 screws.
INSTALLING VALVE
1.
Install new valve assembly.
2. Reverse steps 7-1.
Diagram 5: Lift out Valve Tray Assembly
EV1
EV2
Ground
8.
Remove valve tray assembly.
7.
Remove the 12 screws securing the valve tray assembly in place
(Diagram 4) and then lift the entire assembly out.
Diagram 4 Valve Tray Assembly
Diagram 2
Diagram 3
Rear Log Stand
screws
5.
Disconnect the inlet gas line.
6.
Disconnect the EV1, EV2, and ground wires from the valve - as shown
below.