background image

Regency IP28 Gas Inbuilt Fireplace

3

DIMENSIONS

UNIT DIMENSIONS W/ CONTEMPORARY FACEPLATE

MODULAR FACEPLATE AND INFILL PANEL

37.150

(944mm)

28.180 (716mm

)

18.850 (476mm

)

23.327

(593mm)

14.9

11

(379mm)

27.298

(694mm)

38-5/16"

33-1/2"

28-5/16"

25-7/8"

3/8"

1-5/8"

(973mm)

(848mm)

(657mm)

(719mm)

(41mm)

(10mm)

Содержание IP28-NG

Страница 1: ...light any appli ance Do not touch any electri cal switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department WARNING Improper installation adjustment altera tion service or maintenance can cause injury or property damage Refer to this manual For assistan...

Страница 2: ... provide you with all the warmth and charm of a fireplace at the flick of a switch The model IP28 of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the m...

Страница 3: ...DIMENSIONS UNIT DIMENSIONS W CONTEMPORARY FACEPLATE MODULAR FACEPLATE AND INFILL PANEL 37 150 944mm 28 180 716mm 18 850 476mm 23 327 593mm 14 911 379mm 27 298 694mm 38 5 16 33 1 2 28 5 16 25 7 8 3 8 1 5 8 973mm 848mm 657mm 719mm 41mm 10mm ...

Страница 4: ...4 Regency IP28 Gas Inbuilt Fireplace DIMENSIONS UNIT DIMENSIONS W SLIM LINE FACEPLATE 40 1 2 1030mm 28 5 8 725mm 16 7 8 27 5 16 23 3 8 593mm 427mm 693mm 18 850 475 8 ...

Страница 5: ...8 Gas Inbuilt Fireplace 5 DIMENSIONS DIMENSIONS OPTIONAL MODULAR FIREPLACE SOLUTION DIMENSIONS OPTIONAL WEATHER BOX 49 1245mm 50 3 16 1275mm 34 7 8 886mm 36 15 16 938mm 18 5 16 465mm 1 0 5 775mm 822mm 819mm 410mm ...

Страница 6: ...l Stainless steel inner panel install 21 Switch operation 22 Log set installation 23 Glass Door installation 24 Contemporary faceplate Installation 25 Hearth trim Installation 26 Slim line faceplate Installation 27 Optional infill panel Installation 28 Modular faceplate Installation 29 Final Check 30 Wiring 30 Standard wiring 30 OPERATING INSTRUCTIONS Operating Instructions 31 Lighting Instruction...

Страница 7: ...the label that accompanies each Regency IP28 Gas Inbuilt fireplace We have printed a copy of the contents here for your review DATA BADGE NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 8: ...vironment should be avoided 2 The appliance should be inspected before use and at least annually by an authorised service person More frequent cleaning may be required due to excessive lint from carpet ing bedding material etc It is imperative that control compartments burners and circulating airpassagewaysoftheappliancebekeptclean and free from excessive lint from carpeting 3 Alwaysconnectthisspa...

Страница 9: ... heater when using the Contemporary Fascia are shown in the follow ing diagrams NOTE ALLOW FOR SIDE GAS CONNEC TION IF REQUIRED COMBUSTIBLE MOCK FIREPLACE MINIMUM FIREPLACE OPENING DIMENSIONS The minimum fireplace dimensions for the Regency gas space heater when installing into a combustible mock fireplace are shown in the following diagrams 15 1 8 384mm 23 1 2 597mm 15 1 8 384mm 27 1 2 699mm 27 1...

Страница 10: ...10 Regency IP28 Gas Inbuilt Fireplace INSTALLATION OPTIONAL MODULAR FIREPLACE SOLUTION CLEARANCES 51 7 16 1305mm 39 3 8 1000mm 1 7 16 37mm 36 914mm 51 7 16 1305mm 33 7 16 848mm 25 7 8 655mm 20 5 8 523mm ...

Страница 11: ...REPLACE KIT 1 Install top two 110 mm stand offs to the top of unit Install two 67 mm stand offs to the back of unit install two 55 mm stand offs to the each side of unit 2 Install left and right side nailing flange 3 Lay insulation blanket on top of unit so it is flush and tight against backside of faceplate 4 Unit is now ready for install into a combustible cavity that has the above mentioned cle...

Страница 12: ...ssuretap s turningcounterclockwisewith a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 8mm ID hose 4 Seal and or check the pilot outlet 8 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 Whenfinishedreadingmanometer turnoffthe gasvalve disconnectthehoseandtightent...

Страница 13: ... window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation I For mechanical air inlets including ...

Страница 14: ...degree slope downwards 24 605mm 5 130mm CLEARANCES TO COMBUSTIBLES 10mm is required all around the outer pipe 1 Install inlet tube to back of unit with screws provided and mark cut line Remove inlet tube from unit and cut tube to proper length to ensure sealing at the terminal end 2 Do the same as above for the outer tube Secure to unit mark cut line remove from unit and cut tube to proper length ...

Страница 15: ...pen LPG 15mm open ULPG 15mm open Note Any damage due to carboning resulting from improperly setting the aeration is NOT covered under warranty Burner Inlet Orifice Sizes NG Propane ULPG Burner 39 53 55 Max Input NG 28 8 mj Propane 28 8 mj ULPG 21 mj Supply Pressure NG 1 13 kPa Propane 2 75 kPa ULPG 2 75 kPa Manifold Pressure HIGH LOW NG 0 88 kPa 0 4kPa Propane 2 49 kPa 1 6kPa ULPG 2 49 kPa 1 6kPa ...

Страница 16: ...est input rating by setting the burner switch to HIGH Screw in the nut B to increase the outlet pressure and screw it out to decrease it Use a 10 mm wrench NOTE The outlet pressure must be set to maximum 2 49 kPa WARNING When adjusting maximum pres sure do not screw the nut in fully If unable to obtain 2 49kPa outlet check inlet pressure is adequate Damagemayoccurtothegasvalve if maximum pressure ...

Страница 17: ...move the modulator plastic cap A using needle nose pliers Maximum pressure Turn unit ON to it s highest input rating by setting the burner switch to HIGH Screw in the nut B to increase the outlet pressure and screw it out to decrease it Use a 10 mm wrench NOTE The outlet pressure must be set to maximum 2 49 kPa WARNING When adjusting maximum pres sure do not screw the nut in fully If unable to obt...

Страница 18: ... installation instructions for the venting and termination as referenced in the installation manual Please note WHEN IP28 IS INSTALLED WITHIN THE MFS THE UNIT IS RAISED ENSURE YOUR HOLE TO CENTER IS MARKED AND CUT ACCORDINGLY 2 Once the hole is prepared to install the venting place the MFS center of the hole and flush against the wall and position the gas line and electrical accordingly within the...

Страница 19: ...l to venting Securing brackets Securing bracket MFS Unit 5 Install optional stainless inner panels and remote control if applicable See installation manual for detailed instructions Install decorative log kit as referenced in the installation manual 6 Install the faceplate as referenced in the installation manual under slimline faceplate 7 Ensure the proper gas pressure ...

Страница 20: ...crews on each side 1 Attach the side to the back with 4 screws on each side 3 Attach the bottom to the sides with 3 screws on each side Ensure return edge is on the inside 4 Install back insulation first when in place bend over 4 securing tabs Install left and right sides bending over three tabs each side to secure 5 Add gas cover plate if required 6 With the weather box assembled secure to the ou...

Страница 21: ...e of the panels Use an ammonia based cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove This is not a warranty item 1 Remove the primary guard and faceplate Unplug polarized plug for the switches Refer to instructions in this manual 2 Remove glass and glass retainers Refer to instr...

Страница 22: ...ON SWITCH OPERATION ON OFF REMOTE ON OFF REMOTE HIGH LOW Mj HIGH LOW Mj HIGH LOW FAN HIGH LOW FAN Switch location Contemporary Faceplate Switch operation Contemporary Faceplate Switch location Slim line Faceplate Switch operation Slim line Faceplate ...

Страница 23: ...SET INSTALLATION 1 Install rear log 0113 Ensure proper pin location and positive position on all logs 2 Install left front log 0115 3 Install right front log 0115 4 Install top left cross log 6 Final install 5 Place lava rocks on firebox base in front of logs do not block porting and spread out evenly ...

Страница 24: ... 14 screws securing the glass retainers Remove as many retainers required to either lift or slide the existing glass out Ensure glass does not dislodge 3 Carefully remove and replace the glass 4 With new glass installed in correct position reinstall all glass retainers and screws Ensure all screws are tightened to create a proper seal Do not over tighten NOTE Unit will not operate with glass remov...

Страница 25: ...ry Faceplate with the mock fireplace adjust the framing tabs accordingly 1 Line up faceplate with front of unit Install four 4 screws in locations shown below to secure faceplate 2 Hook up wire harness from faceplate to connection to under unit and check gas connections 4 Reinstall front frame 5 Final install 3 Reinstall bottom louver and install 2 screws in locations shown below ...

Страница 26: ...e INSTALLATION HEARTH TRIM INSTALLATION 1 Line up the hearth trim with the bottom of the fascia until it is flush with the fascia 3 From the backside of the fascia secure the hearth trim with 3 screws on each side in locations shown below ...

Страница 27: ...s accordingly 4 Reinstall bottom louver and install 2 screws in locations shown below 2 Install four 4 screws in locations shown below to secure faceplate 5 Reinstall front frame 1 Remove the stabilizer bar by removing 4 screws install the convention air duct in the same location using the same 4 screws see below 6 Final install 3 Hook up wire harness from faceplate to connection to under unit and...

Страница 28: ... the same loca tion as where screws removed 3 Install 4 support brackets two on the side and two on the top of the unit as shown below 4 Hook the infill panel onto the brackets installed in Step 2 NOTE Support brackets are only required for masonary installations 5 Please see Modular Faceplate instructions to complete installation NOTE Infillpanelisrequiredformockfireplaceapplicationsandoptional f...

Страница 29: ...abs accordingly 4 Reinstall bottom louver and install 2 screws in locations shown below 2 Install four 4 screws in locations shown below to secure faceplate 5 Reinstall front frame 1 Remove the stabilizer bar by removing 4 screws install the convention air duct in the same location using the same 4 screws see below 6 Final install 3 Hook up wire harness from faceplate to connection to under unit a...

Страница 30: ...n for 15 min to stabilize CAUTION Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibil ity of the manufacturer WIRING Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges STANDARD WIRING This unit is polarity sensitive and will not operate if polarity is incorrect CAUTION Label all wi...

Страница 31: ... switch to OFF position Remote Operation Press and release ON OFF button once or turn 3 way switch from Remote position to OFF position FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process To ensure that the paint is properly cured itisrecommendedthatyouburnyourfireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will re...

Страница 32: ...ades from remote wires in heater 1 Connect black to black 2 Connect white to blue Place the receiver in the left hand side on the base of the heater Ensure the receiver aerial is not touching metal components Once you connect the black wire the other 2 wires are identified by the male female connec tor Remote receiver ...

Страница 33: ...NG A BEFORE LIGHTING smell all around the appliance areaforgas Besuretosmellnexttothefloorbecause some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbors phone Follow the gas supplier s instructions If you cannot ...

Страница 34: ... but no ignition module is in lockout Switch off power to unit for 1 minute to reset module ignition after approx 1 minute Then turn on again Unit should ignite after purge time NOTE On initial light up this may occur a number of times until any residual air is purged from the gas line through the burner system It is essential the required waiting time as stated in the manual is observed prior to ...

Страница 35: ...n Note Improper positioning of logs may create carbon build up and will alter the unit s performance which is not covered under warranty DOOR GLASS REPLACEMENT Your Regency stove is supplied with high tem perature 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorised...

Страница 36: ...lug or disconnect power source to stove 3 Open the bottom louvre 4 Remove 2 wing nuts washers securing fan locations shown below 5 Unclip wires from base of unit and unplug fan 6 Disconnect polarized plug 7 Manoeuvre fan from base of unit and replace 8 Reverse steps to reinstall NOTE It is essential that the two washers are re fitted to the fan mounting bolts prior to fitting the wing nuts ...

Страница 37: ...w it to cool to room temperature 2 Unplug or disconnect power source to stove 3 Open the bottom louvre 4 Remove convection fan see previous page 5 Remove 4 screws to release fan 6 Disconnect polarized plug 7 Disconnect tubing from right side of fan 8 Disconnect ground wire 9 Reverse steps to reinstall 8 Manoeuvre fan from base of unit and replace Tubing ...

Страница 38: ...Disconnect wire leads and tubing on the switch NOTE It is important to label wires and hose connections to ensure the new switch is hooked up in the same manner 2 Remove the two screws on the mounting bracket 3 Slide switch out to the left side 4 Remove switch and replace 5 Reverse steps to complete installation Remove 2 screws ...

Страница 39: ...nit off and allow it to cool to room temperature 2 Unplug or disconnect power source to stove 3 Open the bottom louvre to access valve 4 Remove screw in location shown below to release valve cover 5 Partially lift out valve cover 6 Disconnect wires 6 Disconnect wire harness plug 7 Remove screw from rectifier 8 Unplug rectifier from valve ...

Страница 40: ... Inbuilt Fireplace MAINTENANCE 9 Disconnect ground wire from valve 10 Disconnect connection from valve to burner 11 Disconnect connection from valve to gas outlet 12 Remove valve and replace 13 Reverse steps to reinstall ...

Страница 41: ...Grate Assembly IP28 8 456 044 F Bracket side flange right IP28 456 049 F Bracket side flange left IP28 910 082 Ignition Direct Spark Assy Electronic 456 005 Gasket Combustion Fan IP28 456 004 Gasket Valve Tray IP28 911 047 Silicone Tubing 936 232 Gasket Rope 904 658 Inlet Flex Line Gas SS Steel 24 inch 910 088 Wire ECS Module Spark Red 910 089 Wire ECS Module Flame Red 911 041 Wire Harness Ignitio...

Страница 42: ...op IP28 Plate Backing Faceplate IP28 911 043 Wire Harness Control Switch IP28 911 060 Switch Rocker TC201 TB B On Off On 911 061 Switch Rocker TB201 TB B On None On Not available as a replacement part Door Bottom Access Slim F P IP28 Frame Front Slim Faceplate IP28 Faceplate Front IP28 911 043 Wire Harness Control Switch IP28 911 060 Switch Rocker TC201 TB B On Off On 911 061 Switch Rocker TB201 T...

Страница 43: ...d on the unit will carry a 90 day warranty valid with a receipt only Any item shown to be defective will be repaired or replaced at our discretion No labour coverage is included with these parts Conditions All installations must be performed by a qualified gas fitter and installed according to all applicable local and national codes Also all service work must be carried out by a qualified gas serv...

Страница 44: ..._____________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and special offers on related products Help assure you get the most out of your warranty ...

Отзывы: