Regency IP28 Gas Inbuilt Fireplace
15
INSTALLATION
AERATION SETTINGS
The burner aeration is factory set but may need adjusting due to either the local gas supply, air supply or altitude. This adjustment is performed by the installer.
(Close the aeration for a more yellow flame, or open it to make the flame bluer). Please adjust and lock into place via screw.
NG: 7.94mm open
LPG 15mm open
ULPG 15mm open
Note: Any damage due to carboning resulting from improperly setting the aeration is NOT covered under warranty.
Burner Inlet Orifice Sizes:
NG
Propane ULPG
Burner #39
#53
#55
Max. Input
NG
28.8 mj
Propane
28.8 mj
ULPG
21 mj
Supply Pressure
NG
1.13 kPa
Propane
2.75 kPa
ULPG
2.75 kPa
Manifold Pressure HIGH LOW
NG
0.88 kPa 0.4kPa
Propane
2.49 kPa 1.6kPa
ULPG
2.49 kPa 1.6kPa
Electrical: 240 V. 50Hz.
Circulation: High/LO speed fan,
Log Set: Ceramic fibre, 4 per set.
Aeration Setting
NG 7.94mm open
Propane 15mm open
ULPG 15mm open
System Data
IP28