8
Regency IP28 Gas Inbuilt Fireplace
INSTALLATION
IMPORTANT MESSAGE
The Regency Gas Inbuilt must be installed in ac-
cordance with these instructions. Carefully read all
the instructions in this manual fi rst.
Note: Failure to follow these instructions could
cause a malfunction of the heater which
could result in death, serious bodily in-
jury, and/or property damage. Failure to
follow these instructions may also void
your fi re insurance and/or warranty.
FOR YOUR SAFETY
This appliance requires air for proper combustion.
Always provide adequate combustion and ventila-
tion air. Follow instructions and information in the
current AS5601, NZS 5262 or local codes. Consult
the "authority having jurisdiction" to determine the
need for a permit prior to starting the installation.
BEFORE YOU START
INSTALLATION AND REPAIR SHOULD
BE DONE ONLY BY AN AUTHORISED
PERSON.
1)
The appliance shall be installed in accordance
with the manufacturer's installation instructions,
local gas fi tting regulations, municipal building
codes, water supply regulations, electrical wir-
ing regulations, with AS5601. (AGA gas instal-
lation code) NZS 5262(New Zealand). Special
conditions ie. marine environment, should be
avoided.
2)
The appliance should be inspected before
use and at least annually by an authorised
service person. More frequent cleaning may
be required due to excessive lint from carpet-
ing, bedding material, etc. It is imperative that
control compartments, burners and circulating
air passageways of the appliance be kept clean
and free from excessive lint from carpeting.
3)
Always connect this space heater to a approved
fl ueing and termination provided. Flue to the
outside of the building envelope. Never fl ue to
another room.
4)
Inspect
the
fl ueing system annually for blockage
and any signs of deterioration.
5)
Any safety glass removed for servicing must
be replaced prior to operating the appliance.
6)
To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the fi replace.
MATERIALS REQUIRED
A 240 Volt AC power cord is hooked up to the unit.
Plug 3 wire cord into a suitable receptacle. Do not
cut the ground terminal off under any circumstances.
When connected with 240 volts, the appliance
must be electrically grounded in accordance with
local codes.
This unit is polarity sensitive and will not
operate if polarity is incorrect.
The power connection must be accessible with
the appliance installed as per AS5601.
GAS CONNECTION WARNING
Only persons licensed to work with gas piping
may make the necessary gas connections to
this appliance.