background image

FIREPLACE PRODUCTS AUSTRALIA PTY. LTD.                                        

21-23 SOUTH LINK, DANDENONG SOUTH

VICTORIA, 3175  

AUSTRALIA

Printed in Canada

© Copyright 2010, FPI Fireplace Products International Ltd. All rights reserved.

Содержание IP28-LPG

Страница 1: ... any appli ance Do not touch any electri cal switch do not use any phone in your building Immediately call your gas supplierfromaneighbour s phone Follow the gas sup plier s instructions If you cannot reach your gas supplier call the fire department WARNING Improper installation adjustment altera tion service or maintenance can cause injury or property damage Refer to this manual For assistance or...

Страница 2: ... provide you with all the warmth and charm of a fireplace at the flick of a switch The model IP28 of this series has been approved by Australian Gas Association for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the m...

Страница 3: ...Regency IP28 Gas Inbuilt Fireplace 3 DIMENSIONS UNIT DIMENSIONS W CONTEMPORARY FACEPLATE 37 150 944mm 28 180 716mm 18 850 476mm 23 327 593mm 14 911 379mm 27 298 694mm ...

Страница 4: ...4 Regency IP28 Gas Inbuilt Fireplace DIMENSIONS UNIT DIMENSIONS W SLIM LINE FACEPLATE 40 1 2 1030mm 28 5 8 725mm 16 7 8 27 5 16 23 3 8 593mm 427mm 693mm 18 850 475 8 ...

Страница 5: ...Regency IP28 Gas Inbuilt Fireplace 5 DIMENSIONS DIMENSIONS OPTIONAL MODULAR FIREPLACE SOLUTION 49 1245mm 50 3 16 1275mm 34 7 8 886mm 36 15 16 938mm 18 5 16 465mm ...

Страница 6: ...lution Install 17 Optional Stainless steel inner panel install 19 Switch operation 20 Log set installation 21 Glass Door installation 22 Contemporary faceplate Installation 23 Hearth trim Installation 24 Slim line faceplate Installation 25 Final Check 26 Wiring 26 standard WIRING 26 OPERATING INSTRUCTIONS Operating Instructions 27 Lighting Instructions 27 Shutdown Instructions 27 First Fire 27 Rem...

Страница 7: ...THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION OPERATE WITH PANELS COVERS OR GUARDS REMOVED FROM THIS APPLIANCE ENCLOSE THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE NEAR THIS APPLIANCE DO NOT 908 602a Electrical 240VAC 50Hz 1 0 amp Serial Number 918 939 N2134 Regency Gas Fireplace Gas Type NG PROPANE Model IP28 NG IP28 LPG Gas Consumption 28 8mj 28 8mj Manifold Pressure 0 88 kPa 2 49 kPa Injecto...

Страница 8: ...vironment should be avoided 2 The appliance should be inspected before use and at least annually by an authorised service person More frequent cleaning may be required due to excessive lint from carpet ing bedding material etc It is imperative that control compartments burners and circulating airpassagewaysoftheappliancebekeptclean and free from excessive lint from carpeting 3 Alwaysconnectthisspa...

Страница 9: ...er when using the Contemporary Fascia are shown in the follow ing diagrams NOTE ALLOW FOR SIDE GAS CONNEC TION IF REQUIRED COMBUSTIBLE MOCK FIREPLACE MINIMUM FIREPLACE OPENING DIMENSIONS The minimum fireplace dimensions for the Regency gas space heater when installing into a combustible mock fireplace are shown in the following diagrams 15 1 8 384mm 23 1 2 597mm 15 1 8 384mm 27 1 2 699mm 27 1 2 69...

Страница 10: ...10 Regency IP28 Gas Inbuilt Fireplace INSTALLATION OPTIONAL MODULAR FIREPLACE SOLUTION CLEARANCES 51 7 16 1305mm 39 3 8 1000mm 1 7 16 37mm 36 914mm 51 7 16 1305mm 33 7 16 848mm 25 7 8 655mm ...

Страница 11: ...mm stand offs to the top of unit Install two 67 mm stand offs to the back of unit install two 55 mm stand offs to the each side of unit 2 Install left and right side nailing flange 3 Lay insulation blanket on top of unit so it is flush and tight against backside of faceplate 4 Unit is now ready for install into a combustible cavity that has the above mentioned clearances 10mm Top standoffs x 2 Bac...

Страница 12: ...ssuretap s turningcounterclockwisewith a 1 8 wide flat screwdriver 3 Attach manometer to IN and or OUT pressure tap s using a 5 16 8mm ID hose 4 Seal and or check the pilot outlet 8 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 Whenfinishedreadingmanometer turnoffthe gasvalve disconnectthehoseandtightent...

Страница 13: ... window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation I For mechanical air inlets including ...

Страница 14: ...degree slope downwards 24 605mm 5 130mm CLEARANCES TO COMBUSTIBLES 10mm is required all around the outer pipe 1 Install inlet tube to back of unit with screws provided and mark cut line Remove inlet tube from unit and cut tube to proper length to ensure sealing at the terminal end 2 Do the same as above for the outer tube Secure to unit mark cut line remove from unit and cut tube to proper length ...

Страница 15: ...me bluer NG 7 94mm open LPG 15mm open Note Any damage due to carboning resulting from improperly setting the aeration is NOT covered under warranty Burner Inlet Orifice Sizes NG Propane Burner 39 53 Max Input NG 28 8 mj Propane 28 8 mj Supply Pressure NG 1 13 kPa Propane 2 75 kPa Manifold Pressure HIGH LOW NG 0 88 kPa 0 4kPa Propane 2 49 kPa 1 6kPa Electrical 240 V 50Hz Circulation High LO speed f...

Страница 16: ...est input rating by setting the burner switch to HIGH Screw in the nut B to increase the outlet pressure and screw it out to decrease it Use a 10 mm wrench NOTE The outlet pressure must be set to maximum 2 49 kPa WARNING When adjusting maximum pres sure do not screw the nut in fully If unable to obtain 2 49kPa outlet check inlet pressure is adequate Damagemayoccurtothegasvalve if maximum pressure ...

Страница 17: ...enting and termination as referenced in the installation manual Please note WHEN IP28 IS INSTALLED WITHIN THE MFS THE UNIT IS RAISED ENSURE YOUR HOLE TO CENTER IS MARKED AND CUT ACCORDINGLY 2 Once the hole is prepared to install the venting place the MFS center of the hole and flush against the wall and position the gas line and electrical accordingly within the MFS Secure the MFS to the wall usin...

Страница 18: ... Securing brackets Securing bracket MFS Unit 5 Install optional stainless inner panels and remote control if applicable See installation manual for detailed instructions Install decorative log kit as referenced in the installation manual 6 Install the faceplate as referenced in the installation manual under slimline faceplate 7 Ensure the proper gas pressure ...

Страница 19: ...cleaner ie glass cleaner to remove this film before applying heat to the unit Failure to do this will result in burn stains on panels which you will be unable to remove This is not a warranty item 1 Remove the primary guard and faceplate Unplug polarized plug for the switches Refer to instructions in this manual 2 Remove glass and glass retainers Refer to instructions in this manual for detailed i...

Страница 20: ...ON SWITCH OPERATION ON OFF REMOTE ON OFF REMOTE HIGH LOW Mj HIGH LOW Mj HIGH LOW FAN HIGH LOW FAN Switch location Contemporary Faceplate Switch operation Contemporary Faceplate Switch location Slim line Faceplate Switch operation Slim line Faceplate ...

Страница 21: ...all rear log 0113 Ensure proper pin location and positive position on all logs 2 Install left front log 0115 3 Install right front log 0115 4 Install top left cross log 6 Final install 5 Place lava rocks on firebox base in front of logs do not block porting and spread out evenly ...

Страница 22: ... 14 screws securing the glass retainers Remove as many retainers required to either lift or slide the existing glass out Ensure glass does not dislodge 3 Carefully remove and replace the glass 4 With new glass installed in correct position reinstall all glass retainers and screws Ensure all screws are tightened to create a proper seal Do not over tighten NOTE Unit will not operate with glass remov...

Страница 23: ...eplace adjust the framing tabs accordingly 1 Line up faceplate with front of unit Install four 4 screws in locations shown below to secure faceplate 2 Hook up wire harness from faceplate to connection to under unit and check gas connections 4 Reinstall front frame 5 Final install 3 Reinstall bottom louver and install 2 screws in locations shown below ...

Страница 24: ...e INSTALLATION HEARTH TRIM INSTALLATION 1 Line up the hearth trim with the bottom of the fascia until it is flush with the fascia 3 From the backside of the fascia secure the hearth trim with 3 screws on each side in locations shown below ...

Страница 25: ...all bottom louver and install 2 screws in locations shown below 2 Install four 4 screws in locations shown below to secure faceplate 5 Reinstall front frame 1 Remove the stabilizer bar by removing 4 screws install the convention air duct in the same location using the same 4 screws see below 6 Final install 3 Hook up wire harness from faceplate to connection to under unit and check gas connections...

Страница 26: ...ior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation WARNING 240V DISCONNECT POWER TO UNIT PRIOR TO WORKING ON ELECTRICAL COMPONENTS 1 2 3 4 5 6 7 8 9 10 11 12 14 13 10WAYCONNECTOR 2 WAY CONNECTOR RECTIFIER BLUE BROWN BLUE BROWN BROWN WHITE 8 WAY CONNECTOR PURPLE BLK Y G RED BLUE PRESSURESWITCH N C 1 N O 2 OVER TEMPERATURE SWITCH 105 C BLK 6 WAY CON...

Страница 27: ... switch to OFF position Remote Operation Press and release ON OFF button once or turn 3 way switch from Remote position to OFF position FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process To ensure that the paint is properly cured itisrecommendedthatyouburnyourfireplace for at least four 4 hours the first time you use it with the fan on When first operated the unit will re...

Страница 28: ...ades from remote wires in heater 1 Connect black to black 2 Connect white to blue Place the receiver in the left hand side on the base of the heater Ensure the receiver aerial is not touching metal components Once you connect the black wire the other 2 wires are identified by the male female connec tor Remote receiver ...

Страница 29: ...hibit slight carbon deposition FOR YOUR SAFETY READ BEFORE LIGHTING A BEFORE LIGHTING smell all around the appliance areaforgas Besuretosmellnexttothefloorbecause some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neig...

Страница 30: ... but no ignition module is in lockout Switch off power to unit for 1 minute to reset module ignition after approx 1 minute Then turn on again Unit should ignite after purge time NOTE On initial light up this may occur a number of times until any residual air is purged from the gas line through the burner system It is essential the required waiting time as stated in the manual is observed prior to ...

Страница 31: ...n Note Improper positioning of logs may create carbon build up and will alter the unit s performance which is not covered under warranty DOOR GLASS REPLACEMENT Your Regency stove is supplied with high tem perature 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the event that you break your glass by impact purchase your replacement from an authorised...

Страница 32: ...lug or disconnect power source to stove 3 Open the bottom louvre 4 Remove 2 wing nuts washers securing fan locations shown below 5 Unclip wires from base of unit and unplug fan 6 Disconnect polarized plug 7 Manoeuvre fan from base of unit and replace 8 Reverse steps to reinstall NOTE It is essential that the two washers are re fitted to the fan mounting bolts prior to fitting the wing nuts ...

Страница 33: ...w it to cool to room temperature 2 Unplug or disconnect power source to stove 3 Open the bottom louvre 4 Remove convection fan see previous page 5 Remove 4 screws to release fan 6 Disconnect polarized plug 7 Disconnect tubing from right side of fan 8 Disconnect ground wire 9 Reverse steps to reinstall 8 Manoeuvre fan from base of unit and replace Tubing ...

Страница 34: ...Disconnect wire leads and tubing on the switch NOTE It is important to label wires and hose connections to ensure the new switch is hooked up in the same manner 2 Remove the two screws on the mounting bracket 3 Slide switch out to the left side 4 Remove switch and replace 5 Reverse steps to complete installation Remove 2 screws ...

Страница 35: ...nit off and allow it to cool to room temperature 2 Unplug or disconnect power source to stove 3 Open the bottom louvre to access valve 4 Remove screw in location shown below to release valve cover 5 Partially lift out valve cover 6 Disconnect wires 6 Disconnect wire harness plug 7 Remove screw from rectifier 8 Unplug rectifier from valve ...

Страница 36: ... Inbuilt Fireplace MAINTENANCE 9 Disconnect ground wire from valve 10 Disconnect connection from valve to burner 11 Disconnect connection from valve to gas outlet 12 Remove valve and replace 13 Reverse steps to reinstall ...

Страница 37: ... IP28 456 001 Grate Assembly IP28 8 456 044 F Bracket side flange right IP28 456 049 F Bracket side flange left IP28 910 082 Ignition Direct Spark Assy Electronic 456 005 Gasket Combustion Fan IP28 456 004 Gasket Valve Tray IP28 911 047 Silicone Tubing 936 232 Gasket Rope 904 658 Inlet Flex Line Gas SS Steel 24 inch 910 088 Wire ECS Module Spark Red 910 089 Wire ECS Module Flame Red 911 041 Wire H...

Страница 38: ...op IP28 Plate Backing Faceplate IP28 911 043 Wire Harness Control Switch IP28 911 060 Switch Rocker TC201 TB B On Off On 911 061 Switch Rocker TB201 TB B On None On Not available as a replacement part Door Bottom Access Slim F P IP28 Frame Front Slim Faceplate IP28 Faceplate Front IP28 911 043 Wire Harness Control Switch IP28 911 060 Switch Rocker TC201 TB B On Off On 911 061 Switch Rocker TB201 T...

Страница 39: ...e closest approved service agent is situated more than thirty 30 kilometres from the installation Regency is not obliged to arrange warranty repairs and travel and or additional labour charges will apply Porcelain Enamel Absolute perfection is neither guaranteed nor commercially possible Any chips must be reported and inspected by an authorised dealer within three days of installation Reported dam...

Страница 40: ...FIREPLACE PRODUCTS AUSTRALIA PTY LTD 21 23 SOUTH LINK DANDENONG SOUTH VICTORIA 3175 AUSTRALIA Printed in Canada Copyright 2010 FPI Fireplace Products International Ltd All rights reserved ...

Отзывы: