10
Regency I35 Gas Inbuilt Fireplace
INSTALLATION
CONVERSION KIT #486-967 FROM NG TO ULPG
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
Installer Notice:
These instructions must be left
with the appliance.
Conversion Kit #486-967 Contains:
Qty. Part # Description
1 910-037 LPG Injector (Pilot Orifi ce)
1 904-345 Burner Orifi ce #53
1 918-273 Red "ULPG" label
1 918-272 Label "Converted to ULPG"
1 904-529 Allen Key 5/32
1 918-542 Instruction Sheet
1) Shut off the gas supply and unplug the power
cord.
2) Remove the front door.
3) Remove
logs.
4) Remove the rear log tray by removing the 2
screws. (Log tray must be rotated to clear
the burner.)
5) Remove the grate.
6)
Remove the burner and adjust the aeration
setting to 15mm fully open.
Burner Orifi ce
7) Remove
burner
orifi ce with a 1/2" spanner
and discard. Use a spanner to hold on to
the elbow behind the orifi ce.
8) Reinstall new burner orifi ce ULPG stamped
#53 and tighten.
9) Pull off the pilot cap to expose the pilot
orifi ce.
10) Unscrew the pilot orifi ce with the allen key
and replace with the ULPG pilot orifi ce in
the kit.
11) Replace pilot cap.
12) Turn control knob to the "OFF" position.
1 3 ) R e m o v e t h e b l a c k
protection cap by hand
from the hi-low knob
(Fig. 1).
Fig. 1
Fig.2
14) Insert a 5/32" or 4mm
Allen wrench into the
hexagonal key-way of
the screw (Fig. 2), rotate
it counterclockwise until it
is free and extract it.
15) Check that the screw is
clean and if necessary
remove dirt.
16) Flip the srew (Fig. 3).
Fig.3
17) Using the Allen wrench as
shown in Fig. 4, rotate the
screw clockwise until snug,
do not overtighten.
Fig.4
WARNING!
Do not over tighten the screw.
Recommended to grip the
wrench by the short side.
18) Verify that if the conversion is from NG to
ULPG, the screw must be re-assembled
with the red o-ring visible (Fig. 5).
LPG Configuration
Red o-ring visible
Fig.5
19) Re-assemble the black
protection cap (Fig. 6).
Fig. 6
20) Attach the Conversion label "This unit has
been converted to ULPG" on top of the
data badge.
21) Replace yellow "NG" label with red "ULPG"
label.
22) Reverse steps 6 to 1.
23) Check for gas leaks.
24) Check inlet and outlet pressures.
25) Check operation of fl ame control.
26) Check for proper fl ame appearance and
glow on logs.
U