Regency Horizon™ HZ42STEPV Gas Fireplace
23
INSTALLATION
ELECTRICAL INSTALLATION
Note:
For ease of installation, the electrical installation must be completed
prior to adding any fi nishing materials.
1)
Remove faceplate, inner door frame and glass door - refer to
instructions in this manual.
2)
Remove control board located on the lower right side of the unit,by
sliding board out as shown below.
5)
Loosen 2 screws - one on either side of the electrical box. Slide box up
and push box back to release.
6)
Manoeuvre and angle electrical box to remove from the base of the unit.
7)
Install strain relief grommets into opening as shown below.
3)
Locate wiring harness from Power Vent Module - shown below.
4)
Remove access panel - located on the outer right side of the unit, by
removing 4 screws in locations shown below.
Wiring harness from
Power Vent Module
Access panel
Power Vent Module
WARNING
THIS INSTALLATION SHOULD ONLY BE CARRIED
OUT BY A QUALIFIED AND LICENSED ELECTRICIAN
Electrical
Box
(Right side of
Unit)
Important: 120 Volt AC power is required for the power vent
installation.
The receptacle box will be installed on the lower left corner
of the unit and will need to be wired by a qualifi ed electrician
prior to the power vent installation. The neutral (wider) slot
of the polarized receptacle should be at the top. See wiring
diagram in the instruction manual
Strain Relief
Caution: Label all wires prior to disconnection when
servicing controls.
Wiring errors can cause improper and dangerous
operation.