Regency Wood Insert & Hearth Heater
9
installation
Diagram 1:
H2100M and I3100L
Faceplate Assembly
a) H2100M and i3100l insert
1)
Slide the spring nuts (supplied) over the
slots in the insert’s side convection panels
(the spring nuts may need to be squeezed
with a pair of pliers first, to help them stay
in position).
2)
Screw the side faceplate panels, (item A in
the diagram) one to each side.
3)
Using the top panel (item B in the diagram)
as a gauge, check that the side panels are
within approximately 1/4" of the overall width.
If the difference is greater than this, use
the supplied washers to attain the required
width.
B) all units
The unit may now be slid into final position and
attached to the connection system.
Once connection is made, the insulation strips
should be installed between the insert faceplates
and the fireplace face. The faceplate top may
now be installed (with insulation strip behind)
by aligning its brackets with the top flange on
the side shields and the angle iron bar on the
insert top. The faceplate trim may be installed
to the edge of the faceplate at this time.
note: it may be easier to install the insula-
tion, faceplate top and faceplate trim
with the unit pulled slightly away from
the fireplace face. if this is done, be
very careful not to disturb the con-
nector when shifting the unit to its
final position.
Now that your insert is installed, check once
more that all the clearances from the unit to
any combustible materials are correct as listed
earlier.
6)
Once the above items have been checked,
slide your insert into position after first po-
sitioning the flue liner and offset if required.
(Re-install raincap at completion of installa-
tion).
Flush Inserts
Hearth Heater
4)
If the floor of your fireplace is below the
level of the fireplace opening, adjust the
insert's levelling bolts to accommodate the
difference. When additional shimming is
required, use non-combustible masonry or
steel shims.
5)
Measure approximately the alignment of
the flue liner with the position of the smoke
outlet hole on the insert to check for pos-
sible offset. If an offset is required, use a
proper stainless steel unit available with
the chimney liner.
faceplate and triM
Prior to sliding your insert into its final position
and attaching the connector or liner pipe, the
faceplate side panel plates must be installed
as follows: