40
Regency GF900C Gas Fireplace
MAINTENANCE
All maintenance must be carried out by a licensed quali
Į
ed service person
IT IS CRITICAL THAT THIS APPLIANCE IS EARTHED AND THAT THE ACTIVE AND NEUTRAL ARE NOT REVERSED
UNIT OPERATION
ACTION REQUIRED
No gas to the burner
The gas valve should open at the same
Ɵ
me the igni
Ɵ
on commences sparking. If
there is no gas to the burner, turn unit o
ī
. Connect manometer to inlet test point
on the gas valve and check sta
Ɵ
c pressure. If O.K. turn unit on and check there is
no signi
Į
cant drop in the pressure. If O.K. connect manometer to outlet test point
of the gas valve, turn unit on and check outlet pressure is present whilst the spark is
being generated.
Unit sparks, main burner ignites a
Ō
er 5 seconds
This can be caused by incorrect polarity.
spark con
Ɵ
nues even though main
Ň
ame is present
Check that the wall socket to the appliance has correct polarity. If an extension lead
is
ĮƩ
ed check polarity of the lead. Check the polarity of the supply lead to the
appliance.
NOTE: The above checks must be carried out by a quali
Į
ed person
Convec
Ɵ
on fan operates but no
Igni
Ɵ
on module is in lockout, reset module.
igni
Ɵ
on a
Ō
er approx 1 minute
Then turn on again.
NOTE: On ini
Ɵ
al light up this may occur a number of
Ɵ
mes un
Ɵ
l any residual air is
purged from the gas line through the burner system. It is essen
Ɵ
al the required
wai
Ɵ
ng
Ɵ
me as stated in the manual is observed prior to a
ƩĞ
mp
Ɵ
ng re igni
Ɵ
on
Ō
er res
Ğƫ
ng igni
Ɵ
on module, unit s
Ɵ
ll not
Turn burner switch to "ON", fans will operate within 25 secs, listen for audible "click"
Į
rst from
opera
Ɵ
ng a
Ō
er 1 minute
igni
Ɵ
on module, then from pressure switch.
If no "click' heard contact service agent