Regency GF900C Gas Fireplace
17
INSTALLATION
Vent restriction is required for certain venting installations, see the diagrams in the "Venting
Arrangements" section to determine if they are required for your installation.
The Vent Restrictor plate is located on the inside top of the fi rebox.
To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;
1.
Remove the glass door and inner panels - see instructions in this manual.
2.
Remove 6 screws (3 front - 3 back) to remove heat baffl e to access restrictor plate.
VENT RESTRICTOR POSITION
Set 0 - 64mm Open
Set 2 - 18mm open
Set 1 - 26mm open
Set 3 - 15mm open
Heat Baffl e
3.
Remove the screws that hold the vent restrictor in place.
4.
Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown below.
5.
Once the vent restrictor plate is in the required position, secure with screws.