Regency G51 UltraGlow
12
Carefully read the instructions below and refer to the diagrams.
If logs are broken do not use the unit until they are replaced.
Broken logs can interfere with the pilot operation.
The gas log kit (Part #390-930) contains the following pieces:
a) 02-55
Middle Left Log
902-237
b) 02-52
Middle Right Log
902-240
c) 02-51
Front Bottom Log
902-241
d) 02-50
Front Left Log
902-242
e) 02-95
Rear Log
902-375
f ) 02-96
Center Left Log
902-376
g) 02-97
Center Right Log
902-377
i)
Embers Lava
902-156
02-51
02-96
02-50
02-55
02-95
02-97
02-52
The "02" reference numbers (i.e. 02-55) are
moulded into the rear/bottom of each log.
LOG SET
INSTALLATION
1)
Carefully remove the logs from the box and unwrap them. The logs are
fragile, handle with care -
do not force into position.
2)
Place Log 02-95 on the 2 rear log support pins with the flat side of the
log to the back.
Pins
02-95
02-95
3)
Place Log 02-51 on the front right side of the burner. Push the back
of the log against the 2 brackets with the notch on the bottom right
side of the log fitting onto the side of the grate.
02-51
02-95
Brackets
Rest notch on right
side of grate.
4)
Position Log 02-96 across the cutouts in Logs 02-95 and 02-51 with
the notch on the bottom left side of the log fitting into the 2nd grate
tab.
02-95
02-51
02-96
Cutouts
INSTALLATION