Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
33
8) Remove the Side Base Brick Panels and
fi nally the Long Base Brick Panels.
MAINTENANCE
Remove Left & Right Side Base
Brick Panels
Remove the 2 Long Base Brick Panels
9) Open the bottom louvre and remove the 2
screws which secure the front cover to the
valve tray.
7) Slide the burner assembly away from the
orifi ce and lift out.
6) Remove the burner by removing the 4
screws.
10) Unplug the 5 pin Molex Connector and
carefully pull out the control box.
5 Pin Molex
Connector
11) Disconnect the inlet gas line.
12) Unplug the 2 orange wires from the Gas
Pressure Electronic Modulator.
13) Unplug the 5 pin Molex Connector from the
valve.
14) Unplug the igniter and the fl ame cables from
the module.
Igniter and Flame
Cables
15) Remove the 16 screws that secure the valve
tray.
16) Lift the entire assembly out.
17) To replace the burner tray assmebly, reverse
these instructions.
18) Check for any gas leaks.
19) Check for proper fl ame appearance and
glow on logs.
5 Pin Molex Con-
nector from the
Valve.