Regency PG121/PG131 Zero Clearance Room Sealed Gas Fireplace
11
FLUEING
INTRODUCTION
The PG121-1 / PG121LC-1 / PG121RC-1 /
PG131-1 uses the "balanced fl ue" technology
Co Axial system. The inner liner fl ue products of
combustion to the outside while the outer liner
draws outside combustion air into the combus-
tion chamber thereby eliminating the need to
use heated room air for combustion and losing
warm room air up the chimney.
Note: These
fl ue pipes must not be con-
nected to any other appliance.
The gas appliance and fl ue system must be
fl ueed directly to the outside of the building,
and never be attached to a chimney serving a
separate solid fuel or gas burning appliance.
Each direct fl ue gas appliance must use it's own
separate fl ue system. Common fl ue systems
are prohibited.
INSTALLATION
UNIT ASSEMBLY
PRIOR TO
INSTALLATION
The 4 Top Standoffs must be correctly positioned and attached to the top before unit is slipped
into position.
Top Standoff Assembly
The top standoffs are shipped in a fl at position and must be folded into shape and attached.
1) Remove the standoffs from the fi replace
top.
2) Take each standoff and bend into the cor-
rect shape. Bend up at the bend lines until
the screw holes in the standoff and the
pre-punched screw holes on the fi replace
top line up.
3) Attach the standoff securely to the top with
4 screws per standoff (on opposite corners).
FACING & FINISHING REQUIREMENTS
This fi replace is supplied with a 3" metal extension trim above the fi replace. The extension trim may be replaced if the framing is faced with a non-
combustible material placed fl ush with the front and side face of the unit and extending from the top of the unit. (ie. tile, slate, etc.)