Control Box
Cover
Antenna
16)
Remove the control box cover by undo-
ing the 3 screws. Maneuver through an-
tenna.
17)
Remove the jumper using pliers.
21) Adjusting the Outlet Pressure
All the adjustments must be carried out in
the following order:
Remove the modulator plastic cap (A) using
needle nose pliers.
Maximum pressure:
Turn the unit ON to
its highest input rating. Screw in the nut (B)
to increase the outlet pressure and screw it
out to decrease it. Use a 10 mm wrench.
NOTE:
The outlet pressure must be set to
maximum 2.65 kPa.
Minimum pressure:
Remove one of the
cables connected to the electric modulator.
Keeping the nut (B) blocked, screw in the
screw (C) to increase the pressure and screw
it out to decrease it. Use a screwdriver 6 x
1 blade.
NOTE:
The outlet pressure must be set to
minimum 0.74 kPa.
After carrying out all adjustments, block
the setting screws with paint, taking care
not to obstruct the breather orifi ce of the
pressure.
Put back the modulator plastic cap.
WARNING:
To ensure the correct opera-
tion of the modulator it is necessary that
the plastic cap (A) is returned to its original
location.
Cable
Electric
Modulator
Installer Notice:
These instructions must be left
with the appliance.
C
B
A
18)
Stick the conversion label "This unit has
been converted to LPG" on the control box
cover.
19)
Reverse steps 16 and 15.
20)
Turn on gas supply and plug in power
cord.
22)
At the end of all setting and adjustment
operations, check electrical insulation and
gas leaks.
23)
Re-install the glass, louvers and trims.
24)
Check operation of fl ame control.
25)
Check for proper fl ame appearance and
glow on logs.
Jumper