Regency Gosford Freestanding Wood Fire
7
INSTALLATION
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
%
$
(
(
'
*
)
+
&
&
(
(
'
*
)
+
Universal
Default Kit
*(1)
Universal
Default Kit
*(2)
Universal
Default Kit
*(3)
AHD Special
Insulated Kit
*(3)
A
390mm
390mm
390mm
420mm
B
280mm
160mm
220mm
220mm
C
200mm
200mm
200mm
200mm
D
280mm
160mm
220mm
220mm
E
123mm
123mm
123mm
123mm
F
380mm
380mm
380mm
380mm
G
1015mm
1015mm
1015mm
1015mm
H
1200mm
1080mm
1140mm
1140mm
Floor Protection
A combustible fl oor must be protected by non-combustible material (like
tile, concrete board, or as defi ned by local codes) extending beneath
the heater as follows;
From Sides:123mm
From Front: 380mm
From Back: As per D above.
The fl oor protector should consist of 12mm thick cement fi bre sheet
which has a thermal resistance of 0.8m
2
k/w for 4mm sheets of cement
fi bre sheet.
The fl ue pipe shall extend not less
than 4.6m above the top of the
fl oor protector.
NOTE: Installation must be carried
out by a licensed installer in
accordance
with
AS/NZS
2918:2001.
IMPORTANT
* (1) The
Universal Triple Skin Default Kit
when fi tted with either
1 or 2 lengths of 130 degree solid back 900mm decromesh.
* (2) The
Universal Triple Skin Default Kit
with 2 x 900mm 130
degree solid back decromesh and 1 x 450mm stainless shield fi tted
between active fl ue and decromesh.
* (3) The
Universal Triple Skin Default Kit
with 1 x 130 degree
stainless shield x 900mm or 1 x 900mm 130 degree solid back
dec 1 x 450 mm stainless shield fi tted between active fl ue
and decromesh.
* (4) The
AHD Special Insulated Flue Kit
must be installed with a
40mm air gap around the fl ue to any combustible surfaces and the
ceiling ring must be spaced as such to provide an air gap of 10mm
to the ceiling.
The AHD Special Insulated fl ue kit must be installed with a perfo-
rated ceiling plate with 15 x 11mm holes and a 250mm diameter x
150mm high heat shield positioned directly above the ceiling plate.
NOTE:
A minimum clearance of 160mm (fl at wall) or 200mm (corner wall) must be retained for all wall surfaces to allow for fan access and maintenance.