background image

6

Regency Gosford Freestanding Wood Fire

INSTALLATION

1)

  Please read this entire manual before you 

install and use your new wood fi re. Failure 
to follow instructions may result in property 
damage, bodily injury or even death. Be 
aware that local Codes and Regulations may 
override some items in this manual. Check 
with your local inspector.

2)

 

THE APPLIANCE AND FLUE-SYSTEM 
SHALL BE INSTALLED IN ACCORDANCE 
WITH AS/NZS 2918:2001 AND THE AP-
PROPRIATE REQUIREMENTS OF THE 
RELEVANT BUILDING CODE OR CODES.

 

APPLIANCES INSTALLED IN ACCORD-
ANCE WITH THIS STANDARD SHALL 
COMPLY WITH THE REQUIREMENTS OF 
AS/NZS 4013 WHERE REQUIRED BY THE 
REGULATORY AUTHORITY. 

 

ANY MODIFICATION OF THE APPLIANCE 
THAT HAS NOT BEEN APPROVED IN 
WRITING BY THE TESTING AUTHORITY 
IS CONSIDERED TO BE IN BREACH OF 
THE APPROVAL GRANTED FOR COMPLI-
ANCE WITH AS/NZS 4013.

 

CAUTION: MIXING OF APPLIANCE OR 
FLUE-SYSTEM COMPONENTS FROM 
DIFFERENT SOURCES OR MODIFYING 
THE DIMENSIONAL SPECIFICATION OF 
COMPONENTS MAY RESULT IN HAZ-
ARDOUS CONDITIONS. WHERE SUCH 
ACTION IS CONSIDERED, THE MANU-
FACTURER SHOULD BE CONSULTED 
IN THE FIRST INSTANCE.

3) 

Select a position for your Regency Stove. 
Consult the minimum clearance chart for 
your model and set the stove in place. For 
close clearance installation use listed double 
wall connector systems.

4)

  To insure vertical alignment, suspend a plumb 

bob from the ceiling over the exact center 
of your stove fl ue and mark a spot on the 
ceiling to indicate the center of the chimney.

5) 

Check that the area above the ceiling is clear 
for cutting. Re-confi rm the clearance from 
the stove to combustibles to insure that they 
are within the prescribed limits.

6) 

Mark the location of the pedestal base on the 
fl oor, then move the stove aside and mark 
the position of the fl oor protector.

7) 

Install chimney according to chimney manu-
facturers instructions. The performance of 
your wood fi re is governed to a very large 
part by the chimney system. Too short a 
chimney can cause diffi cult start-up, dirty 
glass, backsmoking when door is open, and 

RESIDENTIAL 

INSTALLATION

 

SAFETY GUIDELINES 

AND WARNINGS

1) 

Never use petrol, petrol type lantern fuels, 
kerosene, charcoal lighter fuel, or similar 
liquids to start or ‘freshen up’ a fi re in your 
heater. Keep all such liquids well away from 
the heater while it is in use.

2) 

Keep the door closed during operation and 
maintain all seals in good condition.

3) 

Do not burn any quantities of paper, garbage, 
and never burn fl ammable  fl uids such as 
petrol, naptha or engine oil in your stove.

4) 

If you have smoke detectors, prevent smoke 
spillage as this may set off a false alarm.

5) 

Do not overfi re heater. If the chimney con-
nector, fl ue baffl e or the stove top begin to 
glow, you are overfi ring. Stop adding fuel and 
close the draft control.  Overfi ring can cause 
extensive damage to your stove including 
warpage and premature steel corrosion. 
Overfi ring will void your warranty.

6)

  Do not permit creosote or soot build-up 

in the chimney system. Check and clean 
chimney at regular intervals. Failure to do 
so can result in a serious chimney fi re.

7) 

Your Regency stove can be very hot. You 
may be seriously burned if you touch the 
stove while it is operating, keep children, 
clothing and furniture away.  Warn children 
of the burn hazard. For safety reasons  a 
guard around the fi re is recommended.

8)

  The stove consumes air while operating, 

provide adequate ventilation with an air 
duct or open a window while the stove is in 
use.

9) 

Do not connect this unit to a chimney fl ue 
serving another appliance.

10)

 Do not use grates or andirons or other 

methods for supporting fuel. Burn directly 
on the base or bricks where supplied.

11)

 Open the draft control fully for 10 to 15 

seconds prior to slowly opening the door 
when refuelling the fi re.

12)

 Do not connect your unit to any air distribu-

tion duct.

13)

 Your  wood  fi re should burn dry, standard 

fi rewood only.  The use of cut timber, ply-
wood, “mill ends”, etc. is not allowed as this 
fuel can easily  overheat your wood fi re.  
Evidence of excessive overheating will void 
your warranty.  As well, a large portion of 
sawmill waste is chemically treated timber, 
which is illegal to burn in many areas.  Salt 
drift wood and chemically treated fi re logs 
also must not be burned in your wood fi re.

14)

 No combustible material should be closer 

than the clearances as specifi ed on page 
7.

15)

 

DO NOT OPERATE WITH BROKEN 
GLASS.

even reduced heat output. Too tall a chimney 

may prompt excessive draft which can re-
sult in very short burn times and excessive 
heat output. 

8)

 The fl oor protector must be of non-com-

bustible material.  Refer to page 7 for fl oor 
protector clearances.

9)

 When 

the 

fl oor protection is complete, posi-

tion the stove with the fl ue collar centered 
under the installed chimney.

10)

  In seismically active areas, Regency recom-

mends that your unit is secured to the fl oor 
by using the bolt down holes inside the 
pedestal.

11)

 

Do not connect this unit to a chimney 
serving another appliance.

 

BRICK & CAST
INSTALLATION

Insert the rear cast plate fi rst and then the  side 
plates ensuring the cut out sections lock in fi rmly. 
The bricks can then be placed on the base of the 
fi rebox between the cast side and rear plates.

Firebrick is included to extend the life of your 
stove and radiate heat more evenly.  

Содержание F3000B

Страница 1: ...r property damage Refer to this manual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier GOSFORD FREESTANDING...

Страница 2: ... manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction s...

Страница 3: ...ntenance 10 Door Latch Adjustment 10 Wood Storage 10 PARTS LIST Stove Assembly 11 WARRANTY Warranty 15 Compliance Label 4 Unit Dimensions 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Cast Installation 6 Clearance to Combustibles 7 Floor Protection 7 Wiring Diagram 8 OPERATING INSTRUCTIONS Operating Instructions 9 Air Slide Control 9 ...

Страница 4: ...e label on the unit and if there is a difference the label on the unit is the correct one Regency Freestanding Woodfire Model Gosford F300B TESTED TO AS NZS 4013 1999 TEST REPORT NUMBER HCMG 07 003 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2012 2013 2014 Fireplace Products Australia Pty Ltd 21 23 South Link Dandenong VIC 3175 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 384...

Страница 5: ...Regency Gosford Freestanding Wood Fire 5 DIMENSIONS 566mm 411mm 106mm 289mm 766mm 153mm ID 794mm 167mm 570mm 342mm 336mm 28mm 28mm 902mm 902mm 874mm 540mm GOSFORD F300B ...

Страница 6: ...ors preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopaddingfueland close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the chi...

Страница 7: ...carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Universal Triple Skin Default Kit when fitted with either 1 or 2 lengths of 130 degree solid back 900mm decromesh 2 The Universal Triple Skin Default Kit with 2 x 900mm 130 degree solid back decromesh and 1 x 450mm stainless shield fitted between active flue and decromesh 3 The Universal Triple Skin Default Kit...

Страница 8: ...8 Regency Gosford Freestanding Wood Fire INSTALLATION QWHUQDO ORZHU LULQJ LDJUDP 9 27 52 1 1 875 8 5 1 2 5 77 72 1 7 8 WIRING DIAGRAM ...

Страница 9: ...induction ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE...

Страница 10: ...When ignited this creosote can result in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE AUTHORITY Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every...

Страница 11: ...Rear Panel 7 8010301 Bricks Set Set 9 8 8010302 Liner Cast Iron Set 9 8010303 Liner Cast Iron Sides L R 10 8010305 Liner Cast Iron Back 11 8010306 Air Bar Stainless Steel 12 8010307 Glass Neoceram With Gasket 13 8010313 Door Assembly without handle 14 8010309 Air Slide 15 8010310 Ash Lip Panel 16 8010114 Door Handle Set 17 F250 917 Fan Assembly 18 Pedestal Assembly 19 1406000 Front Panel 20 936 06...

Страница 12: ...12 Regency Gosford Freestanding Wood Fire NOTES ...

Страница 13: ...Regency Gosford Freestanding Wood Fire 13 NOTES ...

Страница 14: ...14 Regency Gosford Freestanding Wood Fire NOTES ...

Страница 15: ...additional labour charges will apply Exclusions This warranty does not extend to or include paint door or glass gasketing neo ceramic glass firebrick or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood downdrafts or spillage caused by environmental conditions nearby trees buildings hilltops mountains inadequate flueing or ventilati...

Страница 16: ...PLACE PRODUCTS AUSTRALIA PTY LTD 21 23 SOUTH LINK DANDENONG SOUTH VICTORIA 3175 AUSTRALIA NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Отзывы: