 During the fi rst few days it may be more 

diffi cult to start the fi re. As you dry out your 
fi rebrick and your masonry fl ue, your draft 
will increase.

10)

  For those units installed at higher elevations 

or into sub-standard masonry fi replaces, 
drafting problems may occur. Consult an 
experienced dealer or mason on methods 
of increasing your draft.

11) 

Some cracking and popping noises may be 
experienced during the heating up process. 
These noises will be minimal when your unit 
reaches temperature.

12)

 Before opening your door to reload, open 

draft fully for approximately 10 to 15 seconds 
until fi re has been re-established. This will 
minimize any smoking.

13)

  All fuel burning appliances consume oxygen 

during operation.  It is important that you 
supply a source of fresh air to your unit 
while burning. A slightly opened window is 
suffi cient for the purpose.  If you also have 
a fi replace in your home, a downdraft may 
be created by your Regency Stove causing 
a draft down your chimney. If this occurs, 
slightly open a window near your unit.

CAUTION:  If the body of your unit, fl ue baffl e 
or any part of the chimney connector starts 
to glow, you are overfi ring.  Stop loading fuel 
immediately and close the draft control until 

the glow has completely subsided.

14) 

Green or wet wood is not recommended for 
your unit.  If you must add wet or green fuel, 
open the draft control fully until all moisture 
has been dispersed by the intense fi re.  
Once all moisture has been removed, the 
draft control may be adjusted to maintain 
the fi re.

15)

 If you have been burning your stove on a 

low draft, use caution when opening the 
door.  After opening the damper, open the 
door a crack, and allow the fi re to adjust 
before fully opening the door.

16)

 The controls of your unit or the air supply 

passages should not be altered to increase 
fi ring for any reason.

17)

 If you burn the unit too slowly or at too low 

a setting your unit will not be operating as 
effi ciently as it can.  An easy rule of thumb 
says that if your glass is clean, then your 
fl ue is clean and your exhaust is clean.  
Burn the stove hot enough to keep your 
glass clean and you won't need to clean 
your fl ue as often.

   

CREOSOTE

When wood is burned slowly, it produces 
tar and other organic vapours, which when 
combined with moisture, form creosote. The 
creosote vapours condense in the relatively 
cool chimney fl ue of a slow burning fi re. As a 
result, creosote residue accumulates on the fl ue 
lining.  When ignited, this creosote can result 
in an extremely hot fi re.

WARNING:  Things to remember in case 
of a chimney fi re:

1. Close all draft and damper controls.

2. CALL THE FIRE AUTHORITY.

Ways to Prevent and Keep Unit 

Free of Creosote

1) 

Burn stove with the draft control wide open 
for about 10-15 minutes every morning 
during burning season.

2) 

Burn stove with draft control wide open for 
about 10 - 15 minutes every time you apply 
fresh wood. This allows the wood to achieve 
the charcoal stage faster and burns up any 
unburned gas vapours which might other-
wise be deposited within the system.

3)  Only burn seasoned wood!

  Avoid burning 

wet or green wood. Seasoned wood has 
been dried at least one year.

4) 

A small hot fi re is preferable to a large 
smouldering one that can deposit creosote 
within the system.

WOOD STORAGE

Store wood under cover, such as in a shed, or 
covered with a tarp, plastic, tar paper, sheets 
of scrap plywood, etc., as uncovered wood can 
absorb water from rain or snow, delaying the 
seasoning process.

MAINTENANCE

It is very important to carefully maintain your 
fi replace stove, including burning seasoned 
wood and maintaining a clean stove and chim-
ney system. Have the chimney cleaned before 
the burning season and as necessary during 
the season, as creosote deposits may build up 
rapidly. Moving parts of your stove require no 
lubrication.

 

5) 

The chimney and chimney connector should 
be inspected at least once every two months 
during the heating season to determine is a 
creosote buildup has occurred.

6)

 

Have chimney system and unit cleaned 
by competent chimney sweeps twice a 
year during the fi rst year of use and at 
least once a year thereafter or when a 
signifi cant layer of creosote has accu-
mulated (3 mm/1/8" or more) it should be 
removed to reduce the risk of a chimney 
fi re. 

GLASS MAINTENANCE

Your Regency stove is supplied with 5mm 
Neoceram ceramic glass that will withstand 
the highest heat that your unit will produce.  In 
the event that you break your glass by impact, 
purchase your replacement from an authorized 
Regency dealer only, and follow our step-by-step 
instructions for replacement. 

Allow the stove to cool down before cleaning 
the glass, do not clean the glass when it is hot. 
Do not use abrasive cleaners.

 

Rear View of Door shown

Pin

Roller

Sleeve

Split 

Pin

Set

Screw

DOOR LATCH

ADJUSTMENT

The door latch may require adjustment as the 
door gasket material compresses over time.  

Follow the steps below to allow the latch to 
be moved closer to the door frame, causing a 
tighter seal;

1)

 Remove split pin and roller sleeve.

2)

 Spin door handle anti-clockwise to tighten.

3)

 Replace split pin and roller sleeve.

* Set screw with Allen key provided.

Содержание F3000B

Страница 1: ...r property damage Refer to this manual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier GOSFORD FREESTANDING...

Страница 2: ... manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction s...

Страница 3: ...ntenance 10 Door Latch Adjustment 10 Wood Storage 10 PARTS LIST Stove Assembly 11 WARRANTY Warranty 15 Compliance Label 4 Unit Dimensions 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Cast Installation 6 Clearance to Combustibles 7 Floor Protection 7 Wiring Diagram 8 OPERATING INSTRUCTIONS Operating Instructions 9 Air Slide Control 9 ...

Страница 4: ...e label on the unit and if there is a difference the label on the unit is the correct one Regency Freestanding Woodfire Model Gosford F300B TESTED TO AS NZS 4013 1999 TEST REPORT NUMBER HCMG 07 003 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2012 2013 2014 Fireplace Products Australia Pty Ltd 21 23 South Link Dandenong VIC 3175 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 384...

Страница 5: ...Regency Gosford Freestanding Wood Fire 5 DIMENSIONS 566mm 411mm 106mm 289mm 766mm 153mm ID 794mm 167mm 570mm 342mm 336mm 28mm 28mm 902mm 902mm 874mm 540mm GOSFORD F300B ...

Страница 6: ...ors preventsmoke spillage as this may set off a false alarm 5 Do not overfire heater If the chimney con nector flue baffle or the stove top begin to glow youareoverfiring Stopaddingfueland close the draft control Overfiring can cause extensive damage to your stove including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the chi...

Страница 7: ...carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Universal Triple Skin Default Kit when fitted with either 1 or 2 lengths of 130 degree solid back 900mm decromesh 2 The Universal Triple Skin Default Kit with 2 x 900mm 130 degree solid back decromesh and 1 x 450mm stainless shield fitted between active flue and decromesh 3 The Universal Triple Skin Default Kit...

Страница 8: ...8 Regency Gosford Freestanding Wood Fire INSTALLATION QWHUQDO ORZHU LULQJ LDJUDP 9 27 52 1 1 875 8 5 1 2 5 77 72 1 7 8 WIRING DIAGRAM ...

Страница 9: ...induction ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE...

Страница 10: ...When ignited this creosote can result in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE AUTHORITY Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every...

Страница 11: ...Rear Panel 7 8010301 Bricks Set Set 9 8 8010302 Liner Cast Iron Set 9 8010303 Liner Cast Iron Sides L R 10 8010305 Liner Cast Iron Back 11 8010306 Air Bar Stainless Steel 12 8010307 Glass Neoceram With Gasket 13 8010313 Door Assembly without handle 14 8010309 Air Slide 15 8010310 Ash Lip Panel 16 8010114 Door Handle Set 17 F250 917 Fan Assembly 18 Pedestal Assembly 19 1406000 Front Panel 20 936 06...

Страница 12: ...12 Regency Gosford Freestanding Wood Fire NOTES ...

Страница 13: ...Regency Gosford Freestanding Wood Fire 13 NOTES ...

Страница 14: ...14 Regency Gosford Freestanding Wood Fire NOTES ...

Страница 15: ...additional labour charges will apply Exclusions This warranty does not extend to or include paint door or glass gasketing neo ceramic glass firebrick or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood downdrafts or spillage caused by environmental conditions nearby trees buildings hilltops mountains inadequate flueing or ventilati...

Страница 16: ...PLACE PRODUCTS AUSTRALIA PTY LTD 21 23 SOUTH LINK DANDENONG SOUTH VICTORIA 3175 AUSTRALIA NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Отзывы: