background image

 

RC500E

  |    

63

parts list

Main Assembly

1

366-574/P

Valve Assembly - NG

1

366-576/P

Valve Assembly - LP

2

911-084

Novasit Valve NG 885 SIT IPI 0.885.001

2

911-085

Novasit Valve LP 885 SIT IPI 0.885.002

3

904-162

Burner Orifice #43 NG

3

904-163

Burner Orifice #54 LP

4

911-006

Pilot Assembly IPI NG 2 Flame 0.199.050

4

911-007

Pilot Assembly IPI LP 2 Flame 

5

910-100

Pilot Orifice NG #51 0.977.166

5

910-101

Pilot Orifice LP #35 0.977.168

6

911-037

Flame Sense 0.915.905

7

911-038

Flame Electrode 0.915.020

8

910-432

Pilot Tube with Nuts

9

911-039

Two Way Pilot Hood 0.975.005

10

911-242

Reset Switch With Wire & Connector

11

911-010

Stepper Motor NG 0.907.013

11

911-011

Stepper Motor LP 0.907.012

12

366-032

Pilot Shield

13

366-525/P

Burner Assembly NG/LP

14

911-174

IFC Control Board Complete 584.306

15

910-246

2 Way Gold Contact Switch

16

197067/P

Replacement Glass (Front) ( Includes Gasket) (Black Door)

16

N/A

Replacement Door With  Glass (Front) ( Includes Gasket) (White Door)

17

197074/P

Replacement Inner Glass (Sides) (Each) ( Includes Gasket)

18

197072/P

Replacement Outer Glass (Sides) (Each) ( Includes Gasket)

19

366-517/P

Fan Assembly Complete

20

910-215/P

Fan Motor Only ( Includes Squirrel Cage)

21

945F

Simpson Duravent Starter Collar

22

197061/P

Top Door Assembly Black

22

197067/P

Top Door Assembly White

23

197052/P

Bottom Cabinet Door Assembly Black

23

197052-AWT/P Bottom Cabinet Door Assembly White

24

366-036

Bottom Inner Access Panel

25

197066

Top Door Handle With Hook

26

948-255

Door Safety Latch 

27

197070

Left Side Panel Black

27

19070-BWT

Left Side White

28

197071

Right Side Panel Black

28

19070-BWT

Right Side White

29

197079

Outer Cast Top Black

29

197081-BWT

Outer Top White

30

366-035F

Top Decorative Cover

31

197083

Cast Grate

32

366-037

Cast Grate Cover

33

366-081

On/Off/Reset Switch Mounting Bracket

Содержание Contura RC500E

Страница 1: ... of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be perform...

Страница 2: ...ovide you with all the warmth and charm of a wood fireplace at the flick of a switch The model RC500E has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency ...

Страница 3: ...85 S I T Valve Description 45 Opening the front glass door 46 Lower access panel removal installation 46 Front grill removal installation 47 Burner removal installation 47 Enamel panel installation 48 Conversion kit from NG to LP 49 Log set installation 51 Optional media installation 54 Optional wall thermostat 55 Manual operation no remote 55 Final check 55 Back up battery 55 Wiring diagram witho...

Страница 4: ...ATION LECTRIQUE 115V_60HZ less than moins de 2 AMP É 467 F Left Side Wall Right Side Wall Horizontal F Left Side Wall Right Side Wall Vertical Pipe E 4 102mm F 50 1270mm Pipe See unit manual for Alcove Clearances B 2 50mm FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY À ER É É UTILIS UNIQUEMENT AVEC LES PORTES VITR ES CERTIFI ES ÉQUIPÉ EN USINE POUR GAZ NATUREL ÉQUIPÉ EN USINE POUR GAZ...

Страница 5: ...ensions with horizontal venting gas line dimensions 40 5 16 42 19 5 16 18 13 16 478mm 490mm 1066mm 1022mm 22 13 16 579mm 1 11 16 R2 3 16 knock out 4 5 16 gas line 5 3 8 to C L base of unit 18 13 16 478mm 19 5 16 490mm 42 1066mm 17 1 4 437mm 44 1 4 1123mm 22 1 8 562mm ...

Страница 6: ...llation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire...

Страница 7: ...pliance s connected to the venting system are located and other spaces of the building 4 Close fireplace dampers 5 Turn on clothes dryers and any appliance not connected to the venting system Turn on any exhaust fans such as range hoods and bathroom exhausts so they are operating at maximum speed Do not operate a summer exhaust fan 6 Follow the lighting instructions Place the appliance being inspec...

Страница 8: ... plug into battery terminals located near the gas valve Do not use both Only use the 4 AA batteries if 120 volt power is not available 3 Install 3 AAA batteries into handheld remote 4 Hold down the black reset button on the left side when facing unit until 3 beeps are heard 5 Hold down the ON OFF button on the hand held remote to code the remote to the receiver after 4 beeps are heard handheld is ...

Страница 9: ...is manual first Consult the building authority having jurisdiction to determine the need for a permit prior to starting the installation Note Failure to follow the instructions could cause a malfunction of the heater which could result in death serious bodily injury and or prop ertydamage Failuretofollowthese instructions may also void your fire insurance and or warranty Note These instructions ta...

Страница 10: ...te is Black Not silver as shown 1 Press the ON OFF button on the remote 2 If service is to be performed you must disconnect power and shut off gas to the unit Remote shown in Manual Mode on Hi NOTE Remotehandheldnotexactlyasshown 3 After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner 4 The unit will turn on lighting procedure Fan Operation The ...

Страница 11: ...llation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosi...

Страница 12: ...igure 2 Transmitter LCD Display TECHNICAL DATA REMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote c...

Страница 13: ... step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room thermostat The thermos...

Страница 14: ...n speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The auxiliary function controls the AUX power outlet by the dimmable light control To activate t...

Страница 15: ... the main ON OFF switch located behindthefrontcoverplate totheOFFposition IMPORTANT The remote control system supplied with this appliance has several options for starting operatingtheappliance pleasereadthe remote control operating instructions packed with remote control to understand how to operate this remote system operation using an optional wall thermostat All Regency stoves ship with a full...

Страница 16: ...d unsupervised operation To activate this function press the MODE and UP Keys at the same time fig 21 To de activate this function press the MODE and UP Keys at the same time Figure 21 LOW BATTERY POWER DETECTION Transmitter The life span of the remote control batteries depends on various factors quality of the batteries used the number of ignitions of the appliance the number of changes to the ro...

Страница 17: ...handle Pull door handle forward to open door Latch Handle manual operation no remote To override the remote open the front lower door and locate the reset button Press the reset button until it beeps 3 times within 10 seconds press and hold the reset button again until a beep is heard After overriding the remote the ON OFF switch located on the lower left inside the lower front door tooltip toolti...

Страница 18: ...front door then close the door 3 T he side safety screens are installed by lining up the tabs on the screen with the glass window frame The screens are held in place with magnets Completed screen install 4 Reverse steps to remove screens levelling leg adjustment 13 13 VANADI UM No 7 CHROME 1 Open up bottom door 2 Remove access panel See manual for details 3 Using a crescent wrench 10 mm adjust the...

Страница 19: ...e logs must be as shown in the diagram under Log Installation Note Improper positioning of logs may createcarbonbuild upandwillalter the unit s performance which is not covered under warranty glass replacement Your stove is supplied with high temperature 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce In the eventthatyoubreakyourglassbyimpact purchase y...

Страница 20: ...se fan motors on a regular basis by vacuuming out the fan squirrel cages around the motor and around the grills on the back of the stove IMPORTANT Disconnect power supply before servicing WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock haz ard and should be plugged directly into a properly grounded three pro...

Страница 21: ... in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspection ...

Страница 22: ...culating air passageways of the appliance be kept clean and free from excessive lint from carpeting 4 See general construction and assembly in structions The appliance and vent should be enclosedwheninstalledinorpassingthrougha livingarea wherechildrenmaycomeincontact with it 5 This appliance must be connected to the speci fied vent and termination cap to the outside of the building envelope Never...

Страница 23: ...natingtheneedtouseheated room air for combustion and losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Each direct vent gas appliance must use it s own separate vent sy...

Страница 24: ...ed above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public pr...

Страница 25: ... be decreased if the alcove was 50 inches 20 E C D A F B 12 Max locating your gas stove When selecting a location for your stove ensure that the clearances listed above are met as well as ensuring that there is adequate accessibility for servicing and proper operation Maximum length will vary depending on vent run See complete details in this manual manufactured mobile home additional requirements...

Страница 26: ...N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanized 46DVA 16A N A N A N...

Страница 27: ... SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK VDV K04 Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Termina...

Страница 28: ...are registered and or proprietary trademarks of Simpson Dura Vent Co Inc This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction with DuraventDirect Vent Pro SelkirkDirect Temp Ameri Vent Direct ICC Excel venting Olympia Ventis and Security SecureVent systems Use of these systems with the Rigid Pipe adaptor is deemed acceptable and does not affect the Intertek WHI...

Страница 29: ...r on Set 3 Vent Restrictor on Set 1 CPI MODE CPI MODE Horizontal venting Vertical venting 40 5 16 1022mm Important The IPI CPI switch on the hand held remote control transmitter must be turned to CPI Continuous Pilot Ignition at all times This will avoid nuisance pilot outages during operation of this appliance when using these venting configurations on this page See Remote manual for setup of thi...

Страница 30: ...30 RC500E installation Venting Arrangements Horizontal venting No Vent Restrictor Factory Set Vent Restrictor Set 2 40 5 16 1022mm ...

Страница 31: ... Two 45o elbows H H1 V H1 H V Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated Option H V H H1 A 1 Max 1 Min 3 Max B 2 Max 2 Min 5 Max C 3 Max 4 Min 6 Max D 4 Max 6 Min 7 Max E 5 Max 8 Min 8 Max With these options max total pipe length is 30 feet with min of 8 feet total ver tical and max 8 feet total horizontal Please note ...

Страница 32: ...ntal Please note min 1 foot be tween90o elbowsisrequired Vent restrictor position A fully open refer to the Vent Restrictor Position section Lengths do not include elbow indicated Option H H1 V A 2 Max 2 Min B 3 Max 3 Min C 4 Max 4 Min D 5 Max 5 Min E 6 Max 6 Min With these options max total pipelengthis30feetwithmin of6feettotalverticalandmax 6 feet total horizontal Please note min 1 foot between...

Страница 33: ...n 40 5 16 1022mm Max 2 0 6m co linear 3 3 flex pipe venting masonry chimney applications only Important The IPI CPI switch on the hand held remote control transmitter must be turned to CPI Continuous Pilot Ignition at all times This will avoid nuisance pilot outages during operation of this appliance when using these venting configurations on this page See Remote manual for setup of this IPI CPI s...

Страница 34: ...nimum and maximum flue lengths See chart below for minimumdistancesfromroof Periodicallycheck that the vent is unrestricted Masonry chimneys may take various contours which the flexible liner will ac commodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Desc...

Страница 35: ...elbow Only cut the uncrimped side of pipe IMPORTANT Donotlocateterminationhoodwhereexces sive snow or ice buildup may occur Be sure to check vent termination area after snow falls and clear to prevent accidental block age of venting system When using snow blowers make sure snow is not directed towards vent termination area Adapter Trim Collar 4 ID Liner Spacer Spring Thimble Cover AstroCap Termina...

Страница 36: ...dening mastic should be run around both the termination and vinyl sidingstandofftopreventwaterfromentering and to make a tight seal between the cap and the standoff 7 Stretchthe4 diameterflexlineroutfullyand get a trial fit of the liner onto the 4 diameter starter collar 8 Cut the 4 diameter flex liner to the desired size Hint leave an extra 12 to 16 of length this will make the final assembly eas...

Страница 37: ...zontal Termination Kit which includes 1 6 5 8 Dia x 12 Black Pipe 1 4 Dia x 12 Aluminum Vent 1 946 202 Wall Penetration Heat Shield Wall Thimble 2 pcs 1 946 523 P AstroCap 1 640 545 P Decorative Wall Trim Black 1 948 128 Tube Mill Pac Screws Optional Components 946 206 Vinyl Siding Standoff AstroCap 946 506 P Vent Guard AstroCap Min 2 51mm clearance to rear of stove Max 12 305mm AstroCap 946 523 P...

Страница 38: ...cular requirements Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the wall thickness Before cutting the vent hole through the wall ensure that ALL vent and termination clearances see the Exterior Vent Terminal locations section will be met Ifthisisanoutsidecorner theminimumdistance between the vent and the outside corner is 6 15cm...

Страница 39: ...allations Warning Always maintain required clearances air spaces to nearby combustibles to prevent a fire hazard Do not fill air spaces with insulation Theminimumclearancerequirementsbetween the outer wall of the vent pipe and nearby combustible surfaces is 1 1 2 except when passingthroughawall ceiling oratthetermina tion where the use of a firestop or wall thimble reduces the required clearance t...

Страница 40: ...Diagram 2 are available as well as the standard Riser Vent Follow the same in stallation procedures as used for standard Horizontal Termination NEVER install the snorkel upside down Diagram 1a Diagram 1 Diagram 2a As specified in CGA B149 Instal lation Code Local codes or regulations may require different clearances Diagram 2b NOTE For Snorkel terminations in ABOVE gradeinstallations follownationa...

Страница 41: ...nstallation NOTE For best results and optimum performance with each approved vent ing system it is highly recommended to apply Mill Pac sealant supplied to everyinnerpipeconnection Failuretodo so may result in drafting or performance issues not covered under warranty Diagram 5 Diagram 6 c Before connecting the vent pipe to the vent termination slide the black decorative wall thimble cover over the...

Страница 42: ...ng or performance issues not covered under warranty 4 Assemble the desired lengths of black pipe and elbows necessary to reach from the appliance adapter up though the Round Support Box Insure that all pipes and elbow connections are in the fully twist locked position and sealed The upper half of the flashing is installed under the roofing material and not nailed down until the chimney is installe...

Страница 43: ...ges during operation of this appliance See Remote manual for setup of this IPI CPI switch 1 Remove the existing chimney cap 2 Measure the distance from the top end of the chimney to the bottom of the ceiling support box add 3 76mm to this measurement and cut a section of the 4 flex pipe to that length the flex should already be extended to it s nominal length 4 Pass the flex pipe down through the ...

Страница 44: ...story vertical installations a Ceil ing Fire stop is required at the second floor and any subsequent floor Diagram 12 The openingshouldbeframedto10 x10 inside dimensions in the same manner as shown in diagram 9 b Any occupied areas above the first floor including closets and storage volcanicces throughwhichtheverticalventpasses must be enclosed cathedral ceilings Round Support RDS Square Support S...

Страница 45: ...lat screwdriver 3 Attach manometer to IN and or OUT pres sure tap s using a 5 16 ID hose 4 Light the pilot and turn the valve to ON posi tion Read manometer 5 The pressure check should be carried out with theunitburningandthesettingshouldbewithin the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise wit...

Страница 46: ...ulling forward 2 Locate latch behind right handle pull latch down 3 Front of latch will drop down and release door handle Pull door handle forward to open door 1 Open lower front door see above Lift lower access panel up 2 Lift lower access panel out of unit 3 Profile of lower access panel showing hook loca tions Reverse steps 1 2 to reinstall Latch Handle ...

Страница 47: ...er or inner panels follow steps below to remove 1 Remove 2 screws from the front of the grill 1 Remove the front grill see above 2 Remove 3 screws in locations show below to release burner 3 Lift burner straight up to remove 2 Slide out lower plate securing the grill then lift the grill up and out 3 Reverse steps to reinstall the grill Grill Lower Plate tooltip tooltip ...

Страница 48: ...ny media if already installed 4 Remove the front grill see manual 5 Remove the 3 screws holding the Burner Assembly to the firebox base Lift burner straight up and lift out to remove tooltip tooltip 9 Lift panel up off the screw and rotate to remove from the unit 6 Loosen 2 screws in locations shown below 7 Lift heat baffle up off screws and remove from unit Profile of heat baffle ip 10 Replace st...

Страница 49: ...actly a fire explosion or production of carbon monoxide may result causing property damage personal injury or loss of life The qualified ser vice agency is responsible for the proper instal lation of this kit The installation is not proper and complete until the operation of the convert ed appliance is checked as specified in the man ufacturer s instructions supplied with the kit 7 Lift off pilot ...

Страница 50: ...on will last approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After this wait time the board will start a second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition after the second attempt the board will go into lock out The system will need to be reset as follows after going...

Страница 51: ...Crushed Iceburg or black glass purchased separately from log set 1 3 5 2 4 6 7 1 Shutoffgasandelectricalsupply allowunittocooltoroomtemperature 2 Open the front door of the unit see manual for detailed instructions 3 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care never force into position 4 Install Log 1 onto pin at the back of the burner Log 1 i...

Страница 52: ...nt of Log 4 Log 1 push left side forward to touch Log 2 Log 4 install onto pins on burner Log 5 install Log 5 placement Glass crushed glass on burner Log 4 11 Install Log 5 place darker in of the log into the triangle created by Logs 1 2 3 Gently place the other end of the log onto the pin on the burner 12 Placement of Log 5 13 Important Spread the 3 4 Black Crystal glass over the burner evenly to...

Страница 53: ...the notch on Log 2 and the pin locator on Log 6 should line up with the pin on Log 4 16 Install Log 7 the darker end will rest in the notch on Log 5 and the opposite end will rest on the bed of crushed glass on the burner 17 Log 7 should touch Log 3 when in position as shown below 18 Place the glowing wool on the crushed glass as shown below Note If the flame picture on the unit is not satisfactor...

Страница 54: ... 2 Remove the 3 screws holding the Burner Assembly to the firebox base Lift burner straight up and lift out to remove 3 Remove the 6 log pins from the burner remove the burner and flip over remove the 6 six screws in locations shown below 4 Re install burner 5 Spread the crushed glass evenly on the burner and place the volcanic stones as shown below do not block the burner ports with the volcanic ...

Страница 55: ...ausessooting orcarboningthatresultsindamagetotheexterior faciaisnottheresponsibilityofthemanufacturer back up battery In the event of a power outage the unit may be operated by a back up battery system 1 Open lower door of unit 2 Install 4 AA batteries into battery pack 3 Attach battery pack to left wall on unit near the reset switch ON OFF switch with velcro manual operation no remote To override...

Страница 56: ...rical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Note 4 AA Batteries must be installed into the back up battery compartment however for this unit to operate when power is lost See b...

Страница 57: ...SE COMFORT USER LAMP COMBUSTION DIAGNOSTIC AUX N L FAN BLOWER INTERFACE INTERFACE LOAD 3 15A T BLACK BROWN YELLOW ORANGE GREEN ORANGE YELLOW GREEN BATTERY HOLDER BLACK RED YELLOW YELLOW SPARK FLAME DETECT BLACK BLACK GREEN MAIN LINE FAN RESET SWITCH ON OFF SWITCH BLACK BLACK GREY GREY RED BLACK WHITE WHITE WHITE WHITE BLACK BLACK BLACK BLACK Thermostat Optional Millivolt ...

Страница 58: ...ote is Black Not silver as shown 1 Press the ON OFF button on the remote 2 If service is to be performed you must disconnect power and shut off gas to the unit Remote shown in Manual Mode on Hi NOTE Remotehandheldnotexactlyasshown 3 After approximately 4 seconds the spark ignition system will spark for 60 seconds to light the main burner 4 The unit will turn on lighting procedure Fan Operation The...

Страница 59: ...taller service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Tout défaut d installation d ajustement de modification de service ou d entretien peut provo quer des blessures ou des dommages matériels Reportez vous au manuel du propr...

Страница 60: ... AWAYTOAVOIDBURNSORCLOTH ING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLY SUPER VISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE 8 Each time the appliance is lit it may cause condensation and fog the glass This conden sation and fog is normal and will disappear in a few minutes as the glass heats up Never operate the appliance without the glass properly secured in place Note If you have an inc...

Страница 61: ... against breakage when installingtheglass Gasketpartnumberis936 238 3 feet in total is required to complete both sides Gasket is sold per foot Glass Your Regency fireplace is supplied with high temperature 5mm Ceramic outer glass and inner glass If your glass requires cleaning we recommend using an approved glass cleaner available at all authorized dealers Do not use abrasive materials CAUTION WAR...

Страница 62: ...62 RC500E parts list Main assembly 1 31 3 4 5 6 7 8 9 12 11 10 13 2 14 38 19 20 33 21 16 23 24 29 36 37 35 25 22 26 34 18 17 28 27 30 50 50 32 18 15 39 ...

Страница 63: ...46 2 Way Gold Contact Switch 16 197067 P Replacement Glass Front Includes Gasket Black Door 16 N A Replacement Door With Glass Front Includes Gasket White Door 17 197074 P Replacement Inner Glass Sides Each Includes Gasket 18 197072 P Replacement Outer Glass Sides Each Includes Gasket 19 366 517 P Fan Assembly Complete 20 910 215 P Fan Motor Only Includes Squirrel Cage 21 945F Simpson Duravent Sta...

Страница 64: ...20 Volts With Connector N S 911 209 Wire 2 Position IFC To Lights N S 911 210 Extended Antenna IFC N S 911 260 Wire 2 Position IFC Burner On Off N S 911 261 Lamp Holder G9 Halogen Light N S 910 780 Wire Red From Fan To Wire Harness N S 910 781 Wire Black From Fan To Wire Harness N S 911 175 Hand Held Remote Control GTMFL SIT 0 584 042 N S 910 692 Green Ground Wire N S W260108 Inner Flue Starter Co...

Страница 65: ...s Gasket Sold Per Foot N S 366 549 Glass Clips Screws Complete Package N S 366 046 Light Socket Bracket ea N S 366 086F Air Adjustment Tool Accessories 50 366 929 Screen Guard complete set N S 366 969 Conversion Kit LP N S 366 908 Enamel panels N S 946 780 3 5 Pounds Crushed Glass Black N S 946 781 3 5 Pounds Crushed Glass Iceburg N S 946 710 Slate Grey Volcanic Stones N S 946 711 Ivory Tan Volcan...

Страница 66: ... to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANADA FP...

Страница 67: ...RC500E 67 notes ...

Страница 68: ...te Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to ...

Страница 69: ...lation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the appliance are ...

Страница 70: ...ditional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and telephone contact ...

Страница 71: ......

Страница 72: ...mation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ______________________________________...

Отзывы: