34
|
RC500E
installation
Flex Liner
Exhaust
Flue
A maximum
of two certified
joiner kits
may be used
per length.
#948-305 (35 ft)
Air Intake
Co-linear DV
Vertical Termination
Cap # 946-529
Co-Linear
Flex
Adapter
with Kit#
946-563
Outer
Pipe
with Kit#
946-563
Inner Pipe
Adapter
with Kit#
946-563
vertical termination with co-linear flex system
This appliance is designed to be attached to
two 3" (76mm) co-linear aluminium flex running
the full length of the chimney. See the Venting
Arrangements chart below for minimum and
maximum flue lengths. See chart below for
minimum distances from roof. Periodically check
that the vent is unrestricted.
Masonry chimneys may take various contours which the flexible liner will ac-
commodate. However,
keep the flexible liner as straight as possible
, avoid
unnecessary bending.
The Air Intake pipe must be attached to the inlet air collar of the termination cap.
Required Parts:
Part #
Description
946-529
Co-linear DV Vertical
Termination Cap
948-305
3" Flex - 35 ft.
946-563
Co-Axial to Co-Linear Adapter Kit
which contains the following:
Co-linear Flex Adapter
Outer Pipe
Inner Pipe Adapter
THE APPLIANCE MUST NOT BE
CONNECTED TO A CHIMNEY FLUE
SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE.