background image

2

 | 

Regency I2400M

 | 

2

Thank-you for purchasing a 

REGENCY FIREPLACE PRODUCT.

The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. Should you have any questions about your product 

that are not covered in this manual, please contact the REGENCY DEALER in your area. Keep those REGENCY FIRES burning.

“This wood heater has a manufacturer set minimum low burn rate that must not be altered. It is against federal regulations to alter this setting or otherwise 

operate this wood heater in a manner inconsistent with operating instructions in this manual." Failure to follow the manual details can lead to smoke and CO 

emissions spilling into the home. It is recommended to have monitors in areas that are expected to generate CO such as heater fuelling areas.

“U.S. ENVIRONMENTAL PROTECTION AGENCY

 Certified to comply with 2015 particulate emission standards using crib wood". Not approved for sale after 

May 15, 2020.”

Model Regency I2400 – 3.4 g /hr.

SAFETY NOTE

: If this woodstove is not properly installed, a house fire may result. For your safety, follow the installation instructions, contact local building, 

fire officials, or authority having jurisdiction about restrictions and installation inspection requirements in your area.

The following statements are required by the Environmental Protection Agency:

“This manual describes the installation and operation of the Regency I2400 wood heater. This heater meets the 2015 U.S. Environmental Protection Agency’s 

crib wood emission limits for wood heaters. Under specific test conditions this heater has been shown to deliver heat at rates ranging from 12,000 BTU/hr. to 

36,800 BTU/hr.” ”This unit has been tested using 5G series and generates the best efficiency when operated using well-seasoned wood and installed in the 

main living areas where the majority of the chimney is within the building envelope and fully lined.”

"It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual, or if any parts are removed. “

It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual.

CAUTION: BURN UNTREATED WOOD ONLY. OTHER MATERIALS SUCH AS WOOD PRESERVATIVES, METAL FOILS, COAL,

PLASTIC, GARBAGE, SULPHUR OR OIL MAY DAMAGE THE HEATER

"This heater is designed to burn natural wood only. Higher efficiencies and lower emissions generally result when burning air dried seasoned hardwoods, as 

compared to softwoods or to green or freshly cut hardwoods."

DO NOT BURN: 

 

•  Treated wood

•  Lawn clippings or yard waste

•  Manure or animal remains

•  Coal

•  Materials containing rubber including tires

•  Saltwater driftwood or other previously salt water 

saturated materials

•  Garbage

•  Materials containing plastic

•  Unseasoned wood

•  Cardboard

•  Waste petroleum products , paints or paint thinners or asphalt products

•  Paper products, cardboard, plywood or particle 

board. The prohibition against burning these 
materials does not prohibit the use of fire starters 
made from paper, cardboard, saw dust, wax and 
similar substances for the purpose of starting a 
fire in a wood heater

•  Solvents

•  Materials containing asbestos

•  Colored Paper

•  Construction or demolition debris

•  Trash

•  Railroad ties

Burning these materials may result in release of toxic fumes or render the heater ineffective and cause smoke. 

The authority having jurisdiction (such as Municipal Building Department, Fire Department, Fire Prevention Bureau, etc.) should be consulted before installa

-

tion to determine the need to obtain a permit.

This unit must be connected to either a listed factory built chimney suitable for use with solid fuels and conforming to ULC629 in Canada or UL-103HT in the 

United States of America or code approved masonry chimney with flue liner.

I2400 is tested and certified to ULC-S628 and UL1482.

SAVE THESE INSTRUCTIONS

Содержание classic i2400m

Страница 1: ... I2400M Wood Fireplace Insert 12 15 16 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com French Manual http ow ly Zvzjy Manuel en Français http ow ly Zvzjy ...

Страница 2: ...ority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY OTHER MATERI...

Страница 3: ...Fireplace 9 Stainless steel smoke deflector Installation 10 Step by step Installation 11 Of The Faceplate And Trim 11 Step by step Installation Of The Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door Handle 13 Screen Door 13 Seasoned wood 14 First Fire 15 Some Safety Guidelines 15 Wood Storage 16 Ash Disposal 16 Fan Operat...

Страница 4: ...RER SUPPLIED SCREEN MUST BE USED REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP IDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING PIÈCES NÉCESSAIRES POUR INSTALLATION 5 5 140MM OR 6 152MM CONDUITS EN ACIER INOXYDABLE COMPOSANT FACULTATIF VENTILATEUR 142 917 CARACTÉRISTIQUES ÉLECTRIQUES NOMINALES 1...

Страница 5: ...Regency I2400M 5 5 dimensions 5 5 9 ...

Страница 6: ... manual before you installanduseyournewwoodinsert Failure to follow instructions may result in property damage bodily injury or even death Install anduseonlyinaccordancewithmanufactur er s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may overr...

Страница 7: ...move it into position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation Convection Grills The convection grills are installed before the unit is positioned inside the fireplace Positionthegrillontheinsidebodyfacesideand fastenusingth...

Страница 8: ...EARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE The specified floor protector should be 3 8 18mm thick material with a K factor of 0 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with ...

Страница 9: ...mneydependsonthelengthofthe chimney local geography nearby obstructions and other factors Too much draft may cause excessive temperatures in the appliance and may cause damage An uncontrollable burn or excessivetemperatureindicatesexcessivedraft Inadequatedraftmaycausebackpuffingintothe room and plugging of the chimney Inadequate draft will cause the appliance to leak smoke into the room through a...

Страница 10: ...oth bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door op...

Страница 11: ...red width 4 The unit may now be slid into final position and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed with insulation stripbehind byaligningitsbracketswiththe top flange on the side shields and the angle iron bar on the insert top The faceplate trim m...

Страница 12: ...mperature or at least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset ...

Страница 13: ...the air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring it back into the hole on the right hand side Use a pair of vise grips or pliers and tap it into place with a hammer A tighter fit will FLUE BAFFLE SECONDARY AIR TUBE INSTALLATION The flue baffle sys...

Страница 14: ...ds like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possib...

Страница 15: ...urn dry standard fire wood only The use of mill ends is discour aged as this fuel can easily overheat your insert Evidence of excessive overheating will void your warranty As well a large por tion of sawmill waste is chemically treated lumber whichisillegaltoburninmanyareas Chemically treated fire logs also must not be burned in your insert WARNING Fireplace Stoves equipped with doors shouldbeoper...

Страница 16: ...fluelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fan is not to be oper ated when the draft control rod is in the closed position pushed in The fully closed position is the low burn setting The fan unit must not be turned on until a fire has been burn...

Страница 17: ...triking or slamming shut GLASS REMOVAL Allowthestovetocoolbeforeremovingorreplacing glass Remove the door from the insert and remove the glass retainer Use caution when removing broken glass to prevent injury When placing the replacement glass in the door makesurethattheglassgasketingwillproperlyseal yourunit Replacetheretainerandtightensecurely but do not wrench down on the glass as this may caus...

Страница 18: ...10 24 Zinc Coated 44 Washer 10 Flat 45 Bolt 10 24 x 3 4 Blk Carriage 47 846 102 Screen Door 948 223 Regency Logo Nickel 48 820 482 Smoke Deflector 919 543 Manual Not available as a replacement part Part Description 1 850 151 Door Assy Large Black 850 153 Door Assy Large Nickel Accent 2 846 304 Glass Replacement 4 936 243 7 8 Adhesive Tape Gasket 5 846 920 Glass Retainer Clips Screws 8 set 6 Screw ...

Страница 19: ...gular 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 297 Trim Left Oversize 298 Faceplate Side Oversize 299 Faceplate Top Oversize Not available as a replacement part 285 286 287 288 288 289 REGULAR 296 295 297 298 299 298 OVERSIZE ...

Страница 20: ...cy I2400M 20 parts list BRICK PANELS I2400M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4 x 2 x 9 ...

Страница 21: ...Regency I2400M 21 21 notes ...

Страница 22: ...Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the defective ...

Страница 23: ... type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados ea...

Страница 24: ...ial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your ad...

Страница 25: ...or us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANA...

Страница 26: ......

Страница 27: ......

Страница 28: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _______________________________________...