CHIMNEY  
SPECIFICATIONS

Before installing, check and clean your chimney 

system thoroughly. If in doubt about its condi-

tion, seek professional advice. Your Regency 

Insert is designed for installation into a masonry 

fireplace that is constructed in accordance with 

the requirements of "The Standard for Chimneys, 

Fireplaces, Vents, and Solid Fuel Burning Ap

-

pliance",  N.F.P.A.  211,  the  National  Building 

Code of Canada, or the applicable local code 

requirements.  

The appliance, when installed, must be electri-

cally grounded in accordance with local codes or, 

in the absence of local codes, with the National 

Electrical Code, ANSI/NFPA 70, or the Canadian 

Electrical code, CSA C22.1.

Regency Inserts are designed to use either a 

5.5" (140mm) or 6" (152mm) flue.

Requirements for Installing 
Solid-fuel Inserts in Factory-built 
Fireplaces.

1)

  The insert must be tested and meet the 

requirements of UL 1482 (U.S.) and or ULC 

S628 (Canada) when tested in a masonry 

fireplace built per ULC S628.

2)

  The factory-built fireplace must be listed per 

UL 127 or ULC S610.

3)

  Clearances obtained from the masonry fire

-

place tests are also relevant for installation 

in factory-built fireplaces.

4)

  Installation must include a full height listed 

chimney liner type HT requirements (2100 

degree  F.)  per  UL  1777  (U.S.)  or  ULC 

S635 (Canada). The liner must be securely 

attached  to  the  insert  flue  collar  and  the 

chimney top.

5)

  Means must be provided to prevent room 

air passage to the chimney cavity of the 

fireplace.  This  may  be  accomplished  by 

sealing the damper area around the chimney 

liner, or sealing the fireplace front.

6)

  Alteration of the fireplace in any manner is not 

permitted with the following exceptions; 

 

a. 

  external trim pieces which do not affect 

the operation of the fireplace may be 

removed providing they can be stored 

on or within the fireplace for re-assembly 

if the insert is removed.

 

b.

   the chimney damper may be removed 

to install the chimney liner.

Regency Inserts are constructed with the high-

est quality materials and assembled under strict 

quality control procedures that insure years of 

trouble free and reliable performance.

It is important that you read this manual thor-

oughly and fully understand the safe instal-

lation and operating procedures.  The more 

you understand the way your Regency Insert 

operates, the more enjoyment you will experi-

ence from knowing that your unit is operating 

at peak performance.

BEFORE INSTALLING 
YOUR INSERT

1)

  Please read this entire manual before you 

install and use your new wood insert. Failure 

to follow instructions may result in property 

damage, bodily injury or even death. Install 

and use only in accordance with manufactur-

er’s installation and operating instructions.

2)

  Check your local building codes - Building 

Inspection Department.  You may require 

a  permit  before  installing  your  insert.  Be 

aware that local codes and regulations may 

override some items in the manual.

  WARNING:  Careless installation is the 

major cause of safety hazard.  Check all 

local building and safety codes before 

installation of unit.

3)

  Notify your home insurance company that 

you plan to install a fireplace insert or hearth 

heater.

4) 

Your fireplace insert is heavy and requires 

two or more people to move it safely.  The 

insert can be badly damaged by mishan-

dling.

5)

  If  your  existing  fireplace  damper  control 

will become inaccessible once you have 

installed your Regency Insert, you should 

either remove or secure it in the open posi-

tion.

6)

  Inspect  your  fireplace  and  chimney  prior 

to installing your insert to determine that it 

is free from cracks, loose mortar or other 

signs of damage.  If repairs are required, 

they should be completed before installing 

your insert.  Do not remove bricks or mortar 

from your masonry fireplace.

7)

 

Do not connect the insert to a chimney 

system servicing another appliance or 

an air distribution duct.

7)

  Circulating air chambers (i.e. in a steel 

fireplace liner or metal heat circulator) shall 

not be blocked.

8)

  Means must be provided for removal of the 

insert to clean the chimney flue.

9)

  Inserts that project in front of the fireplace 

must be supplied with appropriate supporting 

means.

10)

 Installer must mechanically attach the sup-

plied label to the inside of the firebox of the 

fireplace into which the insert is installed.

In  order  for  a  solid-fuel  insert  to  be  certified 

for  use  in  factory-built  fireplaces,  the  above 

information must be clearly stated in the instal-

lation manual and appropriate markings. Final 

approval is contingent on the authority having 

jurisdiction.

WOOD INSERT  
SPECIFICATIONS

Your  fireplace  opening  requires  the  following 

minimum sizes:

  Height:   

21.5"

 Width:

    25"

 Depth:

    17"

Two faceplates are available to seal the fireplace 

opening:  

 

   Standard 

    Oversize

40" W x 30" H 

48" W x 33" H

Emissions from burning  wood or gas could 

contain chemicals known to the State of Cali-

fornia to  cause cancer, birth defects or other 

reproductive harm.

"

WARNING

: This fireplace has been converted 

for use with a wood insert only and cannot be 

used for burning wood or solid fuels unless 

all original parts have been replaced, and the 

fireplace re-approved by the authority having 

jurisdiction."

Содержание classic i2400m

Страница 1: ... I2400M Wood Fireplace Insert 12 15 16 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com French Manual http ow ly Zvzjy Manuel en Français http ow ly Zvzjy ...

Страница 2: ...ority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY OTHER MATERI...

Страница 3: ...Fireplace 9 Stainless steel smoke deflector Installation 10 Step by step Installation 11 Of The Faceplate And Trim 11 Step by step Installation Of The Fan blower 12 Floor Protection 13 Firebrick Assembly 13 Draft Control 13 Flue Baffle Secondary Air Tube Installation 13 Door Handle 13 Screen Door 13 Seasoned wood 14 First Fire 15 Some Safety Guidelines 15 Wood Storage 16 Ash Disposal 16 Fan Operat...

Страница 4: ...RER SUPPLIED SCREEN MUST BE USED REPLACE GLASS ONLY WITH CERAMIC GLASS 5MM INSPECT AND CLEAN CHIMNEY FREQUENTLY UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP IDLY DO NOT OVERFIRE IF INSERT GLOWS YOU ARE OVER FIRING PIÈCES NÉCESSAIRES POUR INSTALLATION 5 5 140MM OR 6 152MM CONDUITS EN ACIER INOXYDABLE COMPOSANT FACULTATIF VENTILATEUR 142 917 CARACTÉRISTIQUES ÉLECTRIQUES NOMINALES 1...

Страница 5: ...Regency I2400M 5 5 dimensions 5 5 9 ...

Страница 6: ... manual before you installanduseyournewwoodinsert Failure to follow instructions may result in property damage bodily injury or even death Install anduseonlyinaccordancewithmanufactur er s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may overr...

Страница 7: ...move it into position The insert can be made a little lighter by removing the cast iron door by opening it and lifting it off its hinges Be sure to protect your hearth extension with a heavy blanket or carpet scrap during the installation Convection Grills The convection grills are installed before the unit is positioned inside the fireplace Positionthegrillontheinsidebodyfacesideand fastenusingth...

Страница 8: ...EARANCES The minimum required clearances to combustible materials when installed into a masonry or factory built fireplace are listed below H HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE The specified floor protector should be 3 8 18mm thick material with a K factor of 0 84 The proposed alternative is 4 100mm brick with a C factor of 1 25 over 1 8 3mm mineral board with ...

Страница 9: ...mneydependsonthelengthofthe chimney local geography nearby obstructions and other factors Too much draft may cause excessive temperatures in the appliance and may cause damage An uncontrollable burn or excessivetemperatureindicatesexcessivedraft Inadequatedraftmaycausebackpuffingintothe room and plugging of the chimney Inadequate draft will cause the appliance to leak smoke into the room through a...

Страница 10: ...oth bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector installed with 2 bolts Note This is a view from the back of the unit through the top Smoke deflector is installed through the door op...

Страница 11: ...red width 4 The unit may now be slid into final position and attached to the connection system 5 Onceconnectionismade theinsulationstrips should be installed between the insert face plates and the fireplace face The faceplate top may now be installed with insulation stripbehind byaligningitsbracketswiththe top flange on the side shields and the angle iron bar on the insert top The faceplate trim m...

Страница 12: ...mperature or at least 30 minutes after starting fire Your fan should only be installed once the unit is in place in order to prevent any damage to the fan To attach follow the instructions provided with the fan 1 Align the fan support with the offset clip on the bottom of the ashlip 2 Slidethesupportsintotheclips Thetension holdingtheclipsinplacemaybeadjustedby increasing or decreasing the offset ...

Страница 13: ...the air tube into the holes in the side channels The notch goes on the right hand side with the air holes facing toward the door Slide the tube into the left hand side as far as possible and then bring it back into the hole on the right hand side Use a pair of vise grips or pliers and tap it into place with a hammer A tighter fit will FLUE BAFFLE SECONDARY AIR TUBE INSTALLATION The flue baffle sys...

Страница 14: ...ds like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possib...

Страница 15: ...urn dry standard fire wood only The use of mill ends is discour aged as this fuel can easily overheat your insert Evidence of excessive overheating will void your warranty As well a large por tion of sawmill waste is chemically treated lumber whichisillegaltoburninmanyareas Chemically treated fire logs also must not be burned in your insert WARNING Fireplace Stoves equipped with doors shouldbeoper...

Страница 16: ...fluelining Whenignited this creosote can make an extremely hot fire FAN OPERATION The fan is to be operated only with the draft control rod pulled out at least 1 2 from the fully closed position The fan is not to be oper ated when the draft control rod is in the closed position pushed in The fully closed position is the low burn setting The fan unit must not be turned on until a fire has been burn...

Страница 17: ...triking or slamming shut GLASS REMOVAL Allowthestovetocoolbeforeremovingorreplacing glass Remove the door from the insert and remove the glass retainer Use caution when removing broken glass to prevent injury When placing the replacement glass in the door makesurethattheglassgasketingwillproperlyseal yourunit Replacetheretainerandtightensecurely but do not wrench down on the glass as this may caus...

Страница 18: ...10 24 Zinc Coated 44 Washer 10 Flat 45 Bolt 10 24 x 3 4 Blk Carriage 47 846 102 Screen Door 948 223 Regency Logo Nickel 48 820 482 Smoke Deflector 919 543 Manual Not available as a replacement part Part Description 1 850 151 Door Assy Large Black 850 153 Door Assy Large Nickel Accent 2 846 304 Glass Replacement 4 936 243 7 8 Adhesive Tape Gasket 5 846 920 Glass Retainer Clips Screws 8 set 6 Screw ...

Страница 19: ...gular 287 Trim Left Regular 288 Faceplate Side Regular 289 Faceplate Top Regular 140 913 Faceplate Trim Set Oversize 180 572 Black Trim Oversize set of 3 295 Trim Right Oversize 296 Trim Top Oversize 297 Trim Left Oversize 298 Faceplate Side Oversize 299 Faceplate Top Oversize Not available as a replacement part 285 286 287 288 288 289 REGULAR 296 295 297 298 299 298 OVERSIZE ...

Страница 20: ...cy I2400M 20 parts list BRICK PANELS I2400M Part Description 180 960 Firebrick Complete Set 70 902 111 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 75 Brick Partial 1 1 4 x 4 1 2 x 2 76 Brick Partial 1 1 4 x 2 x 9 ...

Страница 21: ...Regency I2400M 21 21 notes ...

Страница 22: ...Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that the defective ...

Страница 23: ... type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados ea...

Страница 24: ...ial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your ad...

Страница 25: ...or us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases made in CANA...

Страница 26: ......

Страница 27: ......

Страница 28: ...ation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _______________________________________...

Отзывы: