42
|
Regency
®
CLASSIC™ C34-11 Direct Vent Freestanding Gas Stove
|
42
operating instructions
Incorrect flame pattern will have small, prob-
ably yellow flames, not coming into proper
contact with the rear burner or thermopile
or thermocouple.
PILOT ADJUSTMENT
Periodically check the pilot flames. Correct flame
pattern has three strong blue flames: 1 flowing
around the thermopile, 1 around the thermocouple
and 1 flowing across the burner (it does not have
to be touching the burner).
Note: If you have an incorrect flame pattern,
contact your Regency
®
dealer for further
instructions.
Top View of pilot flame
Top View of pilot flame
AERATION ADJUSTMENT
Natural Gas 5/16"
Propane 5/8"
This adjustment is performed by the installer and
is primarily used in installations at high eleva-
tions. Push in for a yellow flame, or pull out for
a bluer flame. The burner aeration is factory set
but may need adjusting due to either the local
gas supply or altitude.
Caution: Carbon will be produced if air shut-
ter is closed too much.
Note: Aeration Adjustment should only be
performed by an authorized Regency
®
Installer at the time of installation or
service.