background image

30

 | 

Regency

®

 CLASSIC™ C34-11 Direct Vent Freestanding Gas Stove

 | 

30

installation

DURA-VENT  
TERMINATION KIT

Planning Your  Dura-Vent 
Installation

There are two basic types of Dura-Vent Direct 
Vent System installations: horizontal termination 
and vertical termination. Confirm the maximum 
horizontal run and maximum vertical rise from 
the Diagrams in "Venting Arrangments" section.

When planning your installation, it will be nec-
essary to select the proper length of vent pipe 
for your particular requirements. For horizontal 
installations, determine the minimum clearance 
from the rear of the unit to the wall. It is also 
important to note the wall thickness.  (The wall 
thimble is suitable for 2 x 4 or 2 x 6 wall construc-
tion.) Select the amount of vertical rise desired 
for "vertical-to-horizontal" type installations.  

Warning:    Always  maintain  required 

clearances (airspaces) to nearby com

-

bustibles to prevent a fire hazard. Do 

not fill air spaces with insulation. 

The minimum clearance of 1-1/4" (32 mm) is re-
quired between the outer wall of the vent pipe and 
nearby combustible surfaces. Be sure to check 
the  vent  termination  clearance  requirements 
from decks, windows, soffits, gas regulators, air 
supply inlets and public walkways as specified 
in the "Exterior Vent Terminal Locations" section 
and in your local building codes.

To determine the length of vent pipe required 
for vertical installations, measure the distance 
from the unit flue outlet to the ceiling, the ceiling 
thickness, the vertical rise in an attic or second 
storey,  and  allow  for  sufficient  vertical  height 
above the roof line. 

For  multi-storey  applications,  fire  stops  are 
required  at  each  floor  level.  If  an  offset  is 
needed, additional pipe, elbows and supports 
will be required.

You will require the following Dura-Vent venting 
components  with  your  new  CLASSIC  Direct 
Vent  Freestanding  Gas  Stove.  Please  review 
your product to make sure you have everything 
you need. In the event that you are missing any 
part, contact your dealer. 

Note:  These are the minimum components 

required. Other parts may be required 

for your particular installation. See 

"Rigid  Pipe  Venting  Components 

List" section.

If installing termination on a siding covered wall, 
a vinyl siding standoff or furring strips can be 
used in order to ensure that the termination is 
not recessed into siding.

The vinyl siding standoff is required for walls 
with vinyl siding.

Basic 

Horizontal Kit 

1  90

o

 Elbow

1  Wall Thimble Cover
1  Horiz. Sq. Term. Cap

Alternate Horizontal 
Termination Caps

Alternate Horizontal 
Riser Vent Terminal 
Part# 640-530/P

Alternate Snorkel 

Termination Cap 

The FPI AstroCap

TM 

and FPI Riser Vent terminal are certified for installations using FPI venting systems 

as well as Simpson Dura-Vent

®

 Direct Vent , American Metal Products Ameri Vent Direct Vent, Security 

Secure Vent

®

, Selkirk Direct-Temp. AstroCap

TM

 is a proprietary trademark of FPI Fireplace Products 

International Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson 
Dura-Vent Co. Inc.

Содержание C34-LP11

Страница 1: ...s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING FIRE OR EXPLOSION HAZARD Failure to follow safety warnings exactly could result in serious injury death or property damage 920 092e FPI FIREPLACE PRODUCTS INTERNATIONAL LTD 6988 V...

Страница 2: ...ause 5 14 4 the following graphic danger and statements shall be shown on a Class IIIA 2 Permanent Label 4 34 6 Instruction Plate Each appliance shall bear a Class IIIB marking with letters on a contrasting background located adjacent to the controlling device or in an equally conspicuous position where the instruction can be easily read April 22 14 Created draft Double sided Material Synthetic Pa...

Страница 3: ...3 2017 This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance ins...

Страница 4: ...gency CLASSIC C34 11 Direct Vent Freestanding Gas Stove 4 dimensions ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Страница 5: ...Horizontal Vent Kit 28 DV Stove Horizontal Vent Kit Installation 28 Dura Vent Termination Kit 30 Dura Vent Horizontal Installations 31 Vertical Termination 32 Cathedral Ceilings 33 Converting Class A Metal Chimney to Direct Vent System 34 System Data 35 Gas Connection 35 High Elevation 35 Gas Pipe Pressure Testing 35 Door installation 37 Log Installation 39 Door and Glass Frame 39 Safety Screen In...

Страница 6: ...reil selon la norme CAN CSA Z240 Série MM Maison mobiles ou CAN CSA Z240 VC Véhicules de camping ou la norme 24 CFR Part 3280 Manufactured Home Construction and Safety Standard Si ces normes ne sont pas pertinentes utilisez la norme ANSI NCSBCS A225 1 NFPA 501A Manufactured Home Installations Standard ouANSIA119 2 ou NFPA501C Standard for Recreational Vehicles Cet appareil doit être utilisé unique...

Страница 7: ...grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless up...

Страница 8: ... the unit converted to top or rear vent per manual instructions and the insulation discarded Venting YES NO Are the venting components approved for the unit installed Does the venting configuration comply with venting diagrams Is venting installed and secured and are clearances for the vent pipe and termination cap maintained If applicable was a 1 4 rise maintained for every foot of horizontal run...

Страница 9: ...al Was the air shutter on the proper setting after running the unit for 20 minutes If applicable were the surround and trims installed according to the manual Was the operation of the fan lights if installed and flame modulation checked Customer Tutorial and Presentation YES NO Is the customer confident operating the new gas appliance and aware of all the features on the remote Confirm that the ra...

Страница 10: ...NG CHILDREN SHOULD BE CARE FULLY SUPERVISED WHENTHEY ARE IN THE SAME AREA AS THE APPLI ANCE TODDLERS YOUNG CHILDREN AND OTHERS MAY BE SUSCEPTIBLE TO ACCIDENTAL CONTACT BURNS A PHYSICALBARRIERSISRECOMMEND ED IFTHERE ARE AT RISK INDIVIDUAL INTHE HOUSE TO RESTRICT ACCESS TO A FIREPLACE OR STOVE INSTALL AN ADJUSTABLE SAFETY GATE TO KEEP TODDLERS YOUNG CHILDREN ANDOTHERATRISKINDIVIDUALSOUT OF THE ROOM ...

Страница 11: ...e 6 Never vent to another room or inside a build ing Make sure that the vent is fitted as per the instructions starting in Venting Introduction section 7 Inspecttheventingsystemannuallyforblockage and any signs of deterioration 8 Venting terminals shall not be recessed into a wall or siding 9 Any safety glass removed for servicing must be replaced prior to operating the appliance 10 To prevent inj...

Страница 12: ...perDiagramin PilotAdjustment section 6 Install 4 AA batteries into receiver This will enable operation of appliance manually when in ON position 7 Test gas pressure Refer to Gas Pipe Pressure Testing section 8 Install standard and optional features Refer to the following sections where applicable a Log Installation b Door and Glass Frame c Door Handle d Safety Screen e Remote Control f Wall Thermo...

Страница 13: ... last approximately 60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press...

Страница 14: ...EMOTE CONTROL Supply Voltage 4 5V three 1 5V AAA batteries Ambient temperature ratings 0 50o C 32 122o F Radio Frequency 315 MHZ ATTENTION Turn OFF the main gas supply of the appliance during installation or maintenance of the Receiver device Turn OFF main gas supply to the appliance prior to removing or rein serting the batteries In case of remote control malfunction turn off the IFC device using...

Страница 15: ... flame height by one step until the flame is turned off The Up Arrow Key will increase the flame height each time it is pressed If the Up Arrow Key is pressed while the system is on but the flame is off the flame will come on in the high position Fig 7 8 A single beep will confirm reception of the command Fig 7 Fig 8 Room Thermostat Transmitter Operation The Remote Control can operate as a room th...

Страница 16: ... hot air circulating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjustedthroughsix 6 speeds ToactivatethisfunctionusetheModeKey fig 1 to index to the fan control icon Fig 13 Use the Up Down Arrow Keys fig 1 to turn on off or adjust the fan speed fig 14 A single beep will confirm reception of the command Figure 13 Figure 14 Remote dimmer control Light The...

Страница 17: ...ting primed for trouble free start up under colder weather conditions or inversions Keeps the unit glass warm which decreases the amount of condensation on start up Provides owners with flexibility to choose a traditional continuous pilot 7 day Pilot on Demand The primary benefit of having the IPI function is a significant savings on fuel as the pilot will only run when there is a call for heat EN...

Страница 18: ...ve Leg unit Loosen 7 screws on bottom access panel slide panel toward the front to remove IMPORTANT Disconnect power supply before servicing Pedestal unit To install the fan in an installed stove access from front through the pedestal by following the directions below If the stove is not installed access through the back open back as shown below Note Ground lug is located on the bottom of the fan ...

Страница 19: ... grounding lug 9 Remove fan from stove Diagram 3 IMPORTANT THESE FANS COLLECT A LOT OF DUST FROMWITHINYOUR HOME ENSUREYOU MAINTAINTHESE FAN MOTORS ON A REGULAR BASIS BYVACUUMINGTHE FAN BLADES ANDTHE HOUSINGWITH A SOFT BRUSH NOZZLE Note The 8 ground lug is a dedicated ground for mobile home use only 10 Install the FCM fan control module to the floor of the pedestal or bottom heat shield with suppli...

Страница 20: ...e pedestal cover plate Anchoring Brackets Hold Down Package Part 846 585 LEG AND BOTTOM SHIELD ASSEMBLY These instructions apply to the steel leg and painted cast leg It will be easier to attach the legs to the stove if it is tipped on its back preferably on a soft surface to prevent scratching 1 Remove the 4 bolts in the underside of the base and discard 2 Slide the bolt and washer supplied with ...

Страница 21: ...enting systems in combination with the Classic Direct Vent Free standing Gas Stove C34 NG11 and C34 LP11 havebeentestedandlistedasdirectventheater systems by Intertek If converting a Class A Metal Chimney or Masonry Chimney to a Direct Vent system see instructions in Converting Class A Metal Chimney or Masonry Chimney to Direct Vent System section The C34 11usesthe balanced flue technology coaxial...

Страница 22: ... line extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on...

Страница 23: ...0 Black N A N A N A 4DALB N A TC 4DLTB N A Adjustable Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N...

Страница 24: ... AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Riser Vent Terminal 640 530 P Riser Vent Terminal 946 523 P AstroCap Horizontal Cap 946 206 Vinyl Siding Standoff for AstroCap The rigid pipe adaptor is not required on the C34 C34E U39 U39E H15 H27 H35 RC500E Note When using Metal Fab Sure Seal ...

Страница 25: ...enting and Security Secure Vent systems WARNING Do not combine venting components from different venting systems However use of the AstroCapTM and FPI Riser is acceptable with all systems When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to unit The FPI AstroCapTM and FPI Riser Vent terminal are certified for installations using FPI venting systems as we...

Страница 26: ...ion with the factory set vent restrictor position of C Example B Offset to Vertical Vent A 15 ft vertical run with 4 ft horizontal offset distance falls within the shaded area and is an allowable installation with Vent Restrictor Position R Right VENTING ARRANGEMENTS HORIZONTAL TERMINATIONS FOR ALL VENTING SYSTEMS The shaded areas in the Diagram below show all allowable com binations of vertical r...

Страница 27: ...zontal Please note minimum 1 foot between 90o elbows is required Vent restrictor position C fully open refer to Vent Restrictor Position section Lengths do not include elbow indicated Option V H V V1 A 1 Min 4 Max 2 Min B 2 Min 5 Max 3 Min C 3 Min 6 Max 4 Min D 4 Min 7 Max 5 Min E 5 Min 8 Max 6 Min With these options max total pipe length is 30 feet with min of 6 feet total vertical and max 8 feet...

Страница 28: ...ted for any other manufacturer s products Review the following sequence of instructions which are typical of most installations The se quence may vary depending on wall thickness See Locating Your Gas Stove to Exterior Vent Terminal Locations sections for vent location and clearance dimensions 1 Set the unit in its desired location Check to determine if wall studs will be in the way of the venting...

Страница 29: ... 6 A bead of non hardening mastic should be run around both the termination and vinyl siding standoff to prevent water from entering and to make a tight seal between the cap and the standoff 7 Stretch the 4 dia flex liner out fully and get a trial fit of the liner onto the 4 dia starter collar 8 Cut the 4 dia flex liner to the desired size Hint leave an extra 12 to 16 of length this will make the ...

Страница 30: ...nce from the unit flue outlet to the ceiling the ceiling thickness the vertical rise in an attic or second storey and allow for sufficient vertical height above the roof line For multi storey applications fire stops are required at each floor level If an offset is needed additional pipe elbows and supports will be required You will require the following Dura Vent venting components with your new C...

Страница 31: ...nds Diagram 1 Push the pipe sections completely together then twist lock one section clockwise approximately one quarter turn until the two sections are fully locked The female locking lugs will not be visible from the outside on the Black Pipe or fittings They may be located by examining the inside of the female ends Apply sealant Mill Pac to inner pipe and to outer pipe on every twist lock joint...

Страница 32: ...he vent cap assembly into the outer wall of the vent pipe Use the two sheet metal screws provided to connect the strips to the pipe section Bend any remaining portion of the sheet metal strip back towards the vent cap so it will be concealed by the decorative wall thimble cover See Diagram 6 7 Install Wall Thimble in the center of the 10 square and attach with wood screws in Canada 8 Slide the dec...

Страница 33: ...nsure that all pipe and elbow connections are in their fully twist lock position 5 Ensureventisverticalandsecureflashingto the roof with roofing nails Slide the storm collar over the pipe section and seal with a mastic 6 Twist lock the vent cap on to the last section Offset Chart Diagram 12 Diagram 13 Roof Pitch Minimum Vent Height Feet Meters flat to 7 12 2 0 61 over 7 12 to 8 12 2 0 61 over 8 12...

Страница 34: ...ings and ash dumps shall be secured in place and sealed before installing a Direct Vent system within the chimney If the appliance shuts off during operation contact a qualified service person to determine if a negative pressure and or leaky chimney condition exists Do not operate the appliance until the problem is corrected Converting a Factory Built Metal Chimney 1 Remove the existing chimney ca...

Страница 35: ...toff valve must be disconnectedfromthepipingsystem If test pressures equal to or less than 1 2 psig are used then this appliance must be isolated from the piping system by closing its individual manual shutoff valve during the testing HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft CSA 2 17 2017 with the orifice supplied GAS PIPE PRESSURE TESTING The appliance must be isol...

Страница 36: ... 6 Inlet Pressure Tap 7 Pilot Outlet 8 Main Gas Outlet 9 Alternative TC Connection Point 1 Open door on pedestal or heat shield with legs base Remove two 2 screws in locations shown below to remove access panel 2 Install the replacement battery into the DC Sparker Box by opening the battery compartment NOTE The battery in the DC Sparker Box will need to be replaced annually DC SPARKER BATTERY REPL...

Страница 37: ...ling the handle through the hole on the left upper corner Diagram 4 Position the handle in the 8 O clock positions then tighten with 14mm 9 16 wrench Diagram 2 2 Unscrew and turn the door retaining clip outwards then re tighten the screw Diagram 2 Door Handle Assembly Diagram 3 Before After 5 Place the door onto the door hinges Put the hinge cover caps on top of hinges to complete the door Diagram...

Страница 38: ...n hook the tabs on the safety into the slotted brackets on either side of the door Diagram 7 6 Once the door has been placed on the hinge pins secure the door to the unit by screwing the retaining clip to the lower left corner of the unit Diagram 6 Diagram 6 8 To remove the safety screen lift up slightly and pull forward Diagram 7 ...

Страница 39: ...rferewiththepilotand burner operation The gas log kit contains the following a Front Log b Rear Log c Small Cross Logs 2 d Bag of embers e Bag of rockwool f Bag of platinum embers Embaglow supplied with packaged manual 1 Removesecuringscrewfrombracketasshown DO NOT TRY TO TURN THE DOOR HANDLE IT IS NOT DESIGNED TO BE MOVED 6 Placethefrontloginthefrontoftheunit aligning the holes on the underside o...

Страница 40: ... the thermostat is installed on an interior wall Regency offers an optional programmable thermostat but any 250 750 millivolt rated non anticipator type thermostat that is CSA ULC or UL approved may be used CAUTION Do not connect the millivolt wall thermostat wires to the 120V wires Thermostat Wire Table Recommended Maximum Lead Length Two Wire When Using Wall Thermostat CP 2 System Wire Size Max ...

Страница 41: ...nue to operate However a 120V A C power supply is needed for the fan blower operation CAUTION Ensure that the wires do not touch a hot surface and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do...

Страница 42: ...g the burner Note If you have an incorrect flame pattern contact your Regency dealer for further instructions Top View of pilot flame Top View of pilot flame AERATION ADJUSTMENT Natural Gas 5 16 Propane 5 8 Thisadjustmentisperformedbytheinstallerand is primarily used in installations at high eleva tions Push in for a yellow flame or pull out for a bluer flame The burner aeration is factory set but...

Страница 43: ...ertowiremarked receiver which will be located on the bottom of the appli ance This remote control requires coding See remote control instructions for details NOTE This appliance will operate during power outages Onlythefanwillnotoperateuntilpower is restored If the remote batteries in both the handheldtransmitterorreceiverlosepower the appliance can still be operated by sliding the switch on the r...

Страница 44: ...er installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appliance For assistance or additional information consult a qualified installer service agency or gas supplier AVERTISSEMENT Le non respect des instructions du présent manuel risque de déclencher un incendie ou une explosion pouvant entraîner ...

Страница 45: ...Black 6309 3 Theglassshouldbecleanedwithagasfireplace glass cleaner when it starts to turn milky 4 Makea periodiccheckofburnerforproperposi tion and condition Visually check the flame of the burner periodically making sure the flames are steady not lifting or floating If there is a problem call a qualified service person 5 The appliance and venting system must be inspected before use and at least ...

Страница 46: ...valve assembly continue 13 Remove two 2 thermopile wires 14 Remove thermocouple with a 9 mm metric wrench 15 Remove pilot nut with an 11 mm wrench 16 Removevalvetoorificenutwitha13 16 wrench 17 Remove inlet pipe with pipe wrench Note orientation of 90o elbow 18 Remove two 2 phillips head M5 screws on each side of the valve 19 Remove valve and remove gas out 90o brass fitting Note orientation of fi...

Страница 47: ...ms in the list should be checked by a licensed gas service technician during the annual service check Your unit may require more frequent maintenance checks if you notice any changes in how it operates Operational changes to look for can include but are not limited to extended start up time increased fan noise residue carbon build up white build up on the glass firebox increased operating noise et...

Страница 48: ...1 031 Door Retainer Clip 19 948 146 Wood Handle 20 493 917 Complete Fan Assembly Optional 910 157 P Blower Motor 120V 21 910 142 Fan Auto on off Thermodisc 22 910 813 Power Cord 120V 24 Gasket Air Passage 25 Flex Pipe 3 ID 26 Stainless Steel Hose Clamp 27 936 197 Gasket Flue Collar Starter Collar 28 936 194 Gasket Starter Collar Air Passage 30 W260260 Relief Frame Gasket 31 942 117 Top Relief Plat...

Страница 49: ... 911 175 P Remote hand held GTMF Black 911 127 Battery Compartment Door 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 910 096 Pilot Hood 82 910 341 Thermopile 83 910 386 Thermocouple 910 432 Pilot Tube w nuts 910 074 DC spark box wire 911 030 Fan Control Module 911 029 Valve Remote Wiring Harness 84 904 604 36 Orifice NG 84 904 390 52 Orifice LP 936 170 Orifice Gasket 68 936 175 Gasket Top Pla...

Страница 50: ...l Hinge 110 910 327 Strain Relief for Power Cord 121 490 005 Access Panel 140 850 126 Cast Legs Black 4 set 850 128 Cast Legs Brush Nickel 4 set 494 926 Pedestal Assembly 100 948 223 Regency Logo 102 904 257 Magnetic Catch Large 103 11 Pedestal Hinge 110 910 327 Strain Relief for Power Cord 123 490 070 Pedestal Blanking Plate 124 820 058 Pedestal Cover Plate 125 490 002 Rear Cover Plate Not availa...

Страница 51: ...Regency CLASSIC C34 11 Direct Vent Freestanding Gas Stove 51 51 notes ...

Страница 52: ...nition Control Boards Wiring Switches Blowers Blower Control Module Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI fac...

Страница 53: ...es downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction o...

Страница 54: ... outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please inc...

Страница 55: ...on below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For pur...

Страница 56: ......

Страница 57: ...Regency CLASSIC C34 11 Direct Vent Freestanding Gas Stove 57 57 notes ...

Страница 58: ...58 Regency CLASSIC C34 11 Direct Vent Freestanding Gas Stove 58 notes ...

Страница 59: ......

Страница 60: ...n Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial ______________________________________________...

Отзывы: