36
|
Regency
®
CLASSIC™ C34-11 Direct Vent Freestanding Gas Stove
|
36
installation
SIT 829 VALVE DESCRIPTION
1. Gas on/off knob
2. Electronically Operated Hi/Lo
3. Pilot Adjustment
4. Thermocouple Connection - option
5. Outlet Pressure Tap
6. Inlet Pressure Tap
7. Pilot Outlet
8. Main Gas Outlet
9. Alternative TC Connection Point
1. Open door on pedestal or heat shield with legs
base.
Remove two (2) screws in locations shown
below to remove access panel.
2. Install the replacement battery into the
DC Sparker Box by opening the battery
compartment.
NOTE:
The battery in the DC Sparker Box will
need to be replaced annually.
DC SPARKER BATTERY
REPLACEMENT
Pedestal base shown