background image

32     | 

Regency CI1203 / CI1253 Wood Cast Insert

32    |

warranty

Limitations of Liability:  

The original purchaser’s exclusive remedy under this warranty, and FPI’s sole obligation under this warranty, 

express or implied, in contract or in tort, shall be limited to replacement, repair, or refund, as outlined above.  IN 

NO EVENT WILL FPI BE LIABLE UNDER THIS WARRANTY FOR ANY INCIDENTAL OR CONSEQUENTIAL COMMERCIAL 

DAMAGES OR DAMAGES TO PROPERTY.  TO THE EXTENT PERMITTED BY APPLICABLE LAW, FPI MAKES NO EXPRESS 

WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN.  THE DURATION OF ANY IMPLIED WARRANTY IS 

LIMITED TO DURATION OF THE EXPRESSED WARRANTY SPECIFIED ABOVE.  IF IMPLIED WARRANTIES CANNOT BE 

DISCLAIMED, THEN SUCH WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. 

 

Some U.S. states do not allow limitations on how long an implied warranty lasts, or allow exclusion or limitation of 

incidental or consequential damages, so the above limitations or exclusions may not apply to you. 

 

Customers located outside the U.S. should consult their local, provincial or national legal codes for additional 

terms which may be applicable to this warranty. 

 

How to Obtain Warranty Service:

 

Customers should contact the authorized selling dealer to obtain warranty service.  In the event the authorized 

selling dealer is unable to provide warranty service, please contact FPI by mail at the address listed below.  Please 

include a brief description of the problem and your address, email and telephone contact information.  A 

representative will contact you to make arrangements for an inspection and/or warranty service. 

 

Canadian Warrantor: 

 

FPI Fireplace Products International Ltd.

 

6988 Venture St. 

Delta, British Columbia 

Canada, V4G 1H4 

 

U.S. Warrantor:  

 

Fireplace Products U.S., Inc.

 

PO Box 2189 PMB 125 

Blaine, WA 

United States, 98231 

 

Or contact the Regency Customer Care Centre at 1-800-442-7432 (phone) / 604-946-4349 (fax) 

 

Product Registration and Customer Support: 

Thank you for choosing a Regency Fireplace.  Regency strives to be a world leader in the design, manufacture, and 

marketing of hearth products. To provide the best support for your product, we request that you complete a 

product registration form at 

http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx

 within 

ninety (90) days of purchase. 

Revision Date: December 2016 

Regency Wood Products Warranty 

 

Содержание Alterra CI1203

Страница 1: ...C Canada V4G 1H4 919 047d CI1203 CI1253 Alterra Wood Inserts 01 30 18 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference ...

Страница 2: ...where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONLY...

Страница 3: ...ess steel smoke deflector Installation 14 Cast faceplate installation 15 3 piece backing plate installation 18 Door reversal 19 Brick Flue Baffle Secondary Air Tube Installation 20 Firebrick Assembly 20 Draft Control 20 OPERATING INSTRUCTIONS First Fire 21 Fan Operation CI1253 Only 22 Cord reversal 22 Ash Disposal 23 Some Safety Guidelines 23 Creosote 23 MAINTENANCE Door Gasket 24 Glass Cleaning 2...

Страница 4: ... PAS TOUCHER GARDEZ LES EN FANTS VÊTEMENTS ET MEUBLES AU LOIN UN CONTACT AVEC LE PEAU PEUT OC CASIONER DES BRULURES BRÛLURES CUTANÉES LIRE CETTE ÉTIQUETTE CAUTION ATTENTION ADJACENT SIDEWALL A 15in 380mm MANTLE B 20in 510mm TOP FACING C 14in 355 mm SIDE FACING D 7 375in 185mm INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION AND OPERATING INSTRUCTIONS INSTALL AND USE ONLY IN ...

Страница 5: ...OUR AREA JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC 2017 2018 2019 2020 2021 Duplicate Serial MADE IN CANADA 367 DATE OF MANUFACTURE INSTALLER ET UTILISER SELONS LES INSTRUCTIONS DU FABRICANT INSTALLER ET UTILISER DANS UN FOYER DE MACONNERIE OU PRÉFAB RIQUÉ APPELER VOTRE INSPECTEUR DE BÂTIMENT OU LE DÉPARTMENT D INCENDIE LOCAL POUR LES CODES LOCAUX ET POUR INSPECTÉE VOTRE INSTALLATION ET FOY...

Страница 6: ...19 9 16 498mm 9 9 16 15 381mm 18 13 16 478mm 17 11 16 449mm 22 9 16 574mm 244mm 21 3 8 543mm 15 1 16 383mm 9 15 16 250mm 17 432mm NOTE Before assembling your In sert use these dimensions to ensure appropriate clear ances will be met refer to Masonry and Factory Built Fireplace Clearances sec tion 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 14 1 8 from flue centerline to rear of faceplate 16 15 16...

Страница 7: ... 16 579mm 250mm 20 1 2 521mm NOTE Before assembling your In sert use these dimensions to ensure appropriate clear ances will be met refer to Masonry and Factory Built Fireplace Clearances sec tion UNIT DIMENSIONS CI1253 WITH STANDARD BLOWER 6 152mm Diameter STANDARD FLUE ADAPTOR 171 932 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 14 1 8 from flue centerline to rear of faceplate 16 15 16 430mm ...

Страница 8: ... Insert 8 dimensions OPTIONAL BACKING PLATE DIMENSIONS 40 1016mm 40 1016mm 37 940mm 37 914mm 29 1 2 749mm 27 686mm 26 660mm 23 5 8 600mm CI1253 Standard CI1253 Custom Minimum Dimensions CI1203 Custom Minimum Dimensions CI1203 Standard ...

Страница 9: ...on and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the ma jor cause of safety hazard Check all local buildingandsafetycodesbeforeinstallation of unit 3 Notify your home insurance company t...

Страница 10: ...brick 1 C 1 1 25 0 80 1 8 mineralboardofk 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c CompareproposedsystemRof1 231tospeci fied R of 0 893 Since proposed system R is greaterthanrequired thesystemisacceptable DEFINITIONS Thermal Conductance C Btu W hr ft2 o F m2 K Thermal Conductivity k Btu inch W Btu hr ft3 o F m K hr ft o F Thermal Resistance R...

Страница 11: ...required height Secure adaptor using 3 screws 1 in the front and 1 each on the left and right side Flex Liner Diagram 1 Yourinsertisveryheavyandwillrequiretwoorthreepeopletomove it into position Whenhandlingcastparts pleasehandlewithcareastheycanbedamaged 1 Open door to a 45 angle 2 Holding door firmly from top and bottom lift door up and off to remove 3 Lift the unit up onto the Hearth and slide ...

Страница 12: ... flue adaptor as shown in diagram 4 While sliding the unit into place pull on the rod to ensure that the flue adaptor is properly engaged See diagram 5 Pull Rod 10 Ensure that the unit is still level 11 To complete the installation and to ensure a secure fit and connection of the flue adaptor to the insert it is essential that the two bolts flat wash ers and lock washers supplied with packaged man...

Страница 13: ...alledaspertherequirements of your local inspection authority Three methods of flue connection are acceptable in most areas these include 1 Positiveflueconnection wherealargeblocking plate and a short connector pipe is used 2 Directflueconnection whereasmallerblocking plate and a connector pipe to the first flue liner tile is used 3 Full flue liner where a stainless steel rigid or flexible liner pi...

Страница 14: ...h 2 hand tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smok...

Страница 15: ... the bracket on the unit as shown below Line up the left side casting bracket with the left side bracket on the unit Note the CI1200 right left sides are reversible 4 Secure the left cast surround with the two bolts removed in Step 2 5 Repeat Steps 2 and 4 to install right cast surround CI1250 Only 3 Install fan controls into left surround with 2 screws as shown below Note Left side faceplate when...

Страница 16: ...Move the damper control lever to the right so it is out of the way Note If the fan power cord needs to be re routed to the right side of the unit go to step 16 before installing the lower cast surround piece 13 Line up the brackets on the lower cast surround piece with the lower holes in the bracket on the unit Replace two 2 screws removed in step 9 14 Before tightening screws adjust the position ...

Страница 17: ...routed to the right side of the unit if necessary Before installing the lower cast surround run the cord between the left cast surround and the unit Then run the cord along the lower part of the lower cast surround and out in between the right cast and the unit 17 With the cord re routed follow steps 13 15 to complete the installa tion ...

Страница 18: ... 5 Standard backing plate shown on the CI1250 2 The pointed end of the screws should be facing the front of the back ing plate 3 Install 2 clips to the back of the top cast faceplate with hex bolts If the unit is already installed remove the top cast faceplate from the unit if access is too difficult see Cast Faceplate Installation in the owners manual for instructions 4 Slide the backing plate ov...

Страница 19: ... leakage 3 Remove the 2 bolts securing the door catch assembly to the unit 6 Remove the glass from the door and flip it around 180 so the painted strip is at the bottom of the door 7 Flip the handle around 180 and reattach to the door with 2 botls 4 Flip the door hinge 180 install on the left side of the unit with 2 bolts 5 Reattach the door catch assembly on the right side with 2 bolts from step ...

Страница 20: ...into place with a hammer A tighter fit will ensure the tube will not move when the unit is burning 2 Slide the left baffle brick over the front air tube and then slide it back over the rear air tube 3 Tilt the left baffle brick up on top of the side channel and it will leave enough room to posi tion the right baffle brick in the same manner as Step 1 above Then reposition the left baffle brick fla...

Страница 21: ...e left open to provide adequate ventilation while this tempo rary condition exists Burning the insert at a very high temperature the first few times may damage the paint Burn fires at a moderate level the first few days 8 Do not place anything on the insert top during the curing process This may result in damage to your paint finish 9 Duringthefirstfewhoursitmaybemoredifficult to start the fire As...

Страница 22: ...w for fan speed The automatic temperature sensor will engage the blower when the unit is at temperature and will shut off the blower once the fire has gone out and the unit has cooled to below a useful heat output range To manually operate the fan system push the first switch to Man and second switch to either high or Low This will bypass the sensing device and allow full control of the fan Switch...

Страница 23: ...n a noncombustible floor or on the ground well away from all combustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed theyshouldberetainedintheclosedcontaineruntil all cinders have thoroughly cooled Other waste should not be placed in the ash container SOME SAFETY GUIDELINES 1 Neverusegasoline gasolinetypelanternfuels kerosene charc...

Страница 24: ...r care fully swing open and check the clearance to the Right Hand Cast Side Iftightorrubbing loosenthe 7 16nutsandadjusttheclearance and then re tighten GLASS REPLACEMENT Allow the stove to cool before removing or replacing glass Remove the door from the stove and remove the glass retainer Use caution when removing broken glass to avoid injury When placing the replacement glass in the door make su...

Страница 25: ... fires Removal of the spacer washer shown in the diagram below will allow the catch to be moved closer to the door frame causing a tighter seal Remove and replace the nuts washer and spacer as shown TO REMOVE THE FAN 1 See next page Maintenance The sealed bearings are lubricated there is no need to lubricate them further Extra lubricant will cause more lint and dust buildup causing the bearings to...

Страница 26: ...move two 2 screws with 3 16 Allen Key to remove lower cast sur round set aside on a soft surface 4 Lift fan housing up off pins on floor of unit 5 Remove fan from unit 9 To install fan reverse Steps 8 1 6 Remove 3 screws to remove fan heat shield 7 Slide back the protect sheath on the wiring disconnect the black red and white wires 8 Disconnect the ground wire located on the left side of the fan h...

Страница 27: ...rews set of 2 6 Screws 10 24 x 3 8 9 156 514 Door Handle Assembly 11 156 007 Door Catch 12 156 201 Door Assembly Metallic Black no glass 846 570 Med Density Door Gasket Kit 13 156 241 Cast Handle 14 074 954 Air Tube 1 Qty 1 15 033 953 Air Tube 3 4 Qty 1 16 073 955 Baffle 2 set 17 171 932 Standard Flue Adaptor 171 936 Offset Flue Adaptor 18 156 060N Draft plate arm 19 820 483 Stainless smoke deflec...

Страница 28: ... Door Catch 12 156 201 Door Assembly Metallic Black no glass 846 570 Med Density Door Gasket Kit 13 156 241 Cast Handle 14 074 954 Air Tube 1 Qty 1 15 033 953 Air Tube 3 4 Qty 1 16 073 955 Baffle 2 set 17 171 932 Standard Flue Adaptor 171 936 Offset Flue Adaptor 919 047 Manual Not available as a replacement part 1 2 12 19 5 11 18 20 21 13 9 18 910 140 3 way switch 19 910 155 P Fan Assembly 20 156 ...

Страница 29: ... 4 Bottom Surround Not available as a replacement part FIREBRICK Part Description 156 960 Complete Brick Set 1 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 2 Brick Partial 1 1 4 x 2 x 9 3 Brick Partial 1 1 4 x 1 1 4 x 9 4 Brick Partial 1 1 4 x 4 1 2 x 8 5 Brick Partial 1 1 4 x 4 1 4 x 8 6 Brick Partial 1 1 4 x 4 1 2 x 4 1 2 Not available as a replacement part CI1253 Bottom Surround CI1203 Bottom Surr...

Страница 30: ...bly 6 Years Prorated 3 Venting Chimney 1 Screens 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any part s found to be defective during the warranty period as outlined above will be repaired or replaced at FPI s option through an accredited distributor dealer or pre approved and assigned agent provided that th...

Страница 31: ... cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treated or painted lumber metal or foil plastics garbage solvents cardboard coal or coal products oil based products waxed cartons compressed pre manufactured logs lack of regular maintenance and upkeep acts of God weather related problems from hurricanes...

Страница 32: ...egal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and t...

Страница 33: ...w in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases ...

Страница 34: ......

Страница 35: ...35 ...

Страница 36: ...___________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Regency Alterra are trademarks of FPI Fireplace Products International Ltd Copyright 2018 FPI Fireplace Products International Ltd A...

Отзывы: