Regency Albany Freestanding Wood Fire
7
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
INSTALLATION
Hawkwind
Standard
AHD Special
A
400mm
400mm
B
100mm
100mm
C
75mm
125mm
D
100mm
100mm
E
96mm
96mm
F
350mm
350mm
G
880mm
880mm
H
932mm
932mm
Floor Protection
A combustible floor must be protected by non-combustible material (like
tile, concrete board, or as defined by local codes) extending beneath
the heater as follows;
From Sides:
96mm
From Front:
350mm
From Back:
100mm
The floor protector should consist of 12mm thick cement fibre sheet
which has a thermal resistance of 0.8m
2
k/w for 4mm sheets of cement
fibre sheet.
The flue pipe shall extend not less than 4.6m above the top of the floor protector.
NOTE: Installation must be carried out by a licensed installer in accordance
with AS/NZS 2918:2001.
IMPORTANT
* (1) The
Hawkwind Standard flue kit
requires
one 130
o
x 900mm
stainless reflective shield; between the decromesh casing and active
flue.
* (2) The
AHD Special Insulated flue kit
must be installed with a
40mm air gap around the flue to any combustible surfaces and the
ceiling ring must be spaced as such to provide an air gap of 20mm to
the ceiling.
A 180
º
x 900mm stainless reflective must be fitted behind the active
flue.
NOTE:
A minimum clearance of 100mm (flat wall) or 75mm (corner wall) must be retained for all wall surfaces to allow for fan access and maintenance.