Regency Albany Freestanding Wood Fire

6

INSTALLATION

1)

  Please read this entire manual before you 

install and use your new wood fire. Failure 

to follow instructions may result in property 

damage, bodily injury or even death. Be 

aware that local Codes and Regulations may 

override some items in this manual. Check 

with your local inspector.

2)

 

THE APPLIANCE AND FLUE-SYSTEM 

SHALL BE INSTALLED IN ACCORDANCE 

WITH AS/NZS 2918:2001 AND THE AP-

PROPRIATE REQUIREMENTS OF THE 

RELEVANT BUILDING CODE OR CODES.

 

APPLIANCES INSTALLED IN ACCORD-

ANCE WITH THIS STANDARD SHALL 

COMPLY WITH THE REQUIREMENTS OF 

AS/NZS 4013 WHERE REQUIRED BY THE 

REGULATORY AUTHORITY. 

 

ANY MODIFICATION OF THE APPLIANCE 

THAT HAS NOT BEEN APPROVED IN 

WRITING BY THE TESTING AUTHORITY 

IS CONSIDERED TO BE IN BREACH OF 

THE APPROVAL GRANTED FOR COMPLI-

ANCE WITH AS/NZS 4013.

 

CAUTION: MIXING OF APPLIANCE OR 

FLUE-SYSTEM COMPONENTS FROM 

DIFFERENT SOURCES OR MODIFYING 

THE DIMENSIONAL SPECIFICATION OF 

COMPONENTS MAY RESULT IN HAZ-

ARDOUS CONDITIONS. WHERE SUCH 

ACTION IS CONSIDERED, THE MANU-

FACTURER SHOULD BE CONSULTED 

IN THE FIRST INSTANCE.

3) 

Select a position for your Regency Stove. 

Consult the minimum clearance chart for 

your model and set the stove in place. For 

close clearance installation use listed double 

wall connector systems.

4)

  To insure vertical alignment, suspend a plumb 

bob from the ceiling over the exact center 

of your stove flue and mark a spot on the 

ceiling to indicate the center of the chimney.

5) 

Check that the area above the ceiling is clear 

for cutting. Re-confirm the clearance from 

the stove to combustibles to insure that they 

are within the prescribed limits.

6) 

Mark the location of the pedestal base on the 

floor, then move the stove aside and mark 

the position of the floor protector.

7) 

Install chimney according to chimney manu-

facturers instructions. The performance of 

your wood fire is governed to a very large 

part by the chimney system. Too short a 

chimney  can  cause  difficult  start-up,  dirty 

glass, backsmoking when door is open, and 

RESIDENTIAL 

INSTALLATION

even reduced heat output. Too tall a chimney 

may prompt excessive draft which can re-

sult in very short burn times and excessive 

heat output. 

8)

  The  floor  protector  must  be  of  non-com-

bustible material.  Refer to page 7 for floor 

protector clearances.

9)

  When the floor protection is complete, posi-

tion the stove with the flue collar centered 

under the installed chimney.

10)

 In seismically active areas, Regency recom-

mends that your unit is secured to the floor 

by using the bolt down holes inside the 

pedestal.

11)

 

Do not connect this unit to a chimney 

serving another appliance.

 

SAFETY GUIDELINES 

AND WARNINGS

1) 

Never use petrol, petrol type lantern fuels, 

kerosene, charcoal lighter fuel, or similar 

liquids to start or ‘freshen up’ a fire in your 

heater. Keep all such liquids well away from 

the heater while it is in use.

2) 

Keep the door closed during operation and 

maintain all seals in good condition.

3) 

Do not burn any quantities of paper, garbage, 

and never burn flammable fluids such as 

petrol, naptha or engine oil in your stove.

4) 

If you have smoke detectors, prevent smoke 

spillage as this may set off a false alarm.

5) 

Do not overfire heater. If the chimney con-

nector, flue baffle or the stove top begin to 

glow, you are overfiring. Stop adding fuel and 

close the draft control.  Overfiring can cause 

extensive damage to your stove including 

warpage and premature steel corrosion. 

Overfiring will void your warranty.

6)

  Do not permit creosote or soot build-up 

in the chimney system. Check and clean 

chimney at regular intervals. Failure to do 

so can result in a serious chimney fire.

7) 

Your Regency stove can be very hot. You 

may be seriously burned if you touch the 

stove while it is operating, keep children, 

clothing and furniture away.  Warn children 

of the burn hazard. For safety reasons  a 

guard around the fire is recommended.

8)

  The stove consumes air while operating, 

provide adequate ventilation with an air duct 

or open a window while the stove is in use.

9) 

Do not connect this unit to a chimney flue 

serving another appliance.

10)

 Do not use grates or andirons or other 

methods for supporting fuel. Burn directly 

on the base or bricks where supplied.

11)

 Open the draft control fully for 10 to 15 

seconds prior to slowly opening the door 

when refuelling the fire.

12)

 Do not connect your unit to any air distribu-

tion duct.

13)

 Your wood fire should burn dry, standard 

firewood only.  The use of cut timber, ply-

wood, “mill ends”, etc. is not allowed as this 

fuel  can  easily    overheat  your  wood  fire.  

Evidence of excessive overheating will void 

your warranty.  As well, a large portion of 

sawmill waste is chemically treated timber, 

which is illegal to burn in many areas.  Salt 

drift wood and chemically treated fire logs 

also must not be burned in your wood fire.

14)

 No combustible material should be closer 

than the clearances, see page 7.

15)

 

DO NOT OPERATE WITH BROKEN 

GLASS.

 

CAST PLATE

INSTALLATION

Install the cast plates by placing the rear cast 

plate first and then the  side plates ensuring the 

cut out sections lock in firmly. 

Firebrick

Cast Plate

Содержание Albany F200B-1

Страница 1: ... additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier Model F200B 1 Albany F200B 1 Freestanding Wood Fire FPI FIREPLACE PRODUCTS A...

Страница 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Страница 3: ...rnings 6 Cast Plate Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 MAINTENANCE Maintenance 9 Creosote 9 Ways to Prevent Keep Units Free of Creosote 9 Glass Maintenance 9 Door Latch Adjustment 9 Wood Storage 9 PARTS LIST Stove Assembly 10 WARRANTY Warranty 11 ...

Страница 4: ... the label that accompanies each F200B 1 Freestanding Wood Fire We have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Albany Freestanding Wood Fire 5 UNIT DIMENSIONS ...

Страница 6: ...recom mends that your unit is secured to the floor by using the bolt down holes inside the pedestal 11 Do not connect this unit to a chimney serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater while it is in...

Страница 7: ...mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Hawkwind Standard flue kit requires one 130o x 900mm stainless reflective shield between the decromesh casing and active flue 2 The AHD Special Insulated flue kit must be ...

Страница 8: ...le OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESERV...

Страница 9: ...in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every time you apply freshwood Thisallowst...

Страница 10: ... Neoceram with Gasket 7 8010612 Door Assembly without handle 8 8010114 Door Handle Set 9 8010104 Secondary Air Tube 10 8010108 Firebrick optional or where fitted x 16 11 Pedestal Assembly 12 8010609 Ashlip Panel 13 8010610 Fan Assembly Complete 8010611 Steel baffle A 7510206 Cast Plate Set B 14 8010113 Metal lip inside firebox 15 8010115 Glass retaining bracket 16 936 060 Door rope seal 5 ft not s...

Страница 11: ...is the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products will not be liable for r...

Страница 12: ..._____________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and...

Отзывы: