32
|
F5200 Regency Freestanding Woodstove
|
32
maintenance
Annual Maintenance
Completely clean out entire unit
Annually
Inspect air tube, Catalytic Combustor and bricks
Replace any damaged parts.
Adjust door catch assembly
If unable to obtain a tight seal on the door - replace door gasket seal.
Readjust door catch after new gasket installed.
Inspect condition and seal of:
Glass Gasket
Door Gasket
Bypass Door Gasket
Perform paper test - replace gasket if required
Paper Test
Test the seal on the loading door and bypass door with a paper bill.
Place a paper bill in the gasket area of the door on a cold stove.
Close the door.
Try to remove the paper by pulling.
The paper should not pull out easily; if it does, try adjusting the door latch (load-
ing door only). If that doesn't solve the problem, replace the door gasket, bypass
gasket, or both.
Check and lubricate door hinge + latch
Use only high temperature anti seize lube. (ie. never seize)
Check glass for cracks
Replace if required.
Clean blower motor
Disconnect power supply.
Remove and clean blower.
*DO NOT LUBRICATE*
Inspect and clean chimney
Annual professional chimney cleaning recommended.
DOOR CATCH
ADJUSTMENT
The door catch may require adjustment as the door gasket compresses after a
few fires. The door catch compression may require adjustment to renew seal.
Removal of the spacer washer, shown in the Diagram below, will allow the
catch to be moved closer to the door frame, causing a tighter seal. Remove
and replace the nuts, washer and spacer as shown
Spacer washers
DOOR HINGE
ADJUSTMENT
If the door hinge ever requires adjustement, ensure that the bolt is put on
hand tight and tightened a further 1/2 turn using a wrench.
Do not overthighten as this can damage the bolt or nutsert.
Note: Some models may only have 1 bolt at the top. This version shows 2
top bolts.
Door Hinge
bolts
Chimney Cleaning
When cleaning the chimney system the catalyst should be removed so this can also be cleaned at the same time following the guide lines found in this ma-
nual. The bypass should be open so any creosote will fall onto the firebox floor when being cleaned and door closed. The monitor should also be removed
when cleaning is being done to prevent damage to the monitor.
We highly recommend that the chimney cleaning be done by a professional as they will have the necessary tools such as a proper sized brush and special
vacuum cleaner designed to deal with fine particles.