F5200 Regency Freestanding Woodstove
|
29
29
|
maintenance
BYPASS DOOR GASKET REPLACEMENT
1.
Allow the stove to burn out and cool down, until cool to touch.
2.
Open stove door to access bypass door.
5.
Remove old gaskets and replace with new ones.
4.
Slide bypass door assembly forward, lower complete assembly with care.
Lift lid on bypass door assembly to reveal gasket.
3.
Loosen the 3 rear nuts, then remove 3 front nuts. Support the Bypass Door
from the front /back and slide forward to remove Bypass Door Assembly.
Note: if any of the bolts become damaged, the bolt bracket assemblies may
be replaced—see next page.
Important
: Bypass door is very heavy (>18 lbs) - use caution when servicing.
6
. Reverse steps to reinstall - ensure the pass rod is seated with the channel
on the pass door.
(Unit viewed as transparent to facilitate view)
Pass Rod
Channel
Loosen 3 rear nuts
F5200 Damper Assembly Draft