I1200 Regency Wood Insert

4

SAFETY LABEL

This is a copy of the label that accompanies each 

I1200S Wood Insert

. We have printed a copy 

of the contents here for your review.

LISTED F

ACT

OR

Y

 BUIL

T FIREPLACE INSERT

CERTIFIED FOR USE IN CANADA

 AND U.S.A.

MODEL: 

I1200S

TESTED T

O

:

ULC S628-M93  / UL

 1482-1998 / ULC S627-00 / UL

 737-2000 

 

REPORT NO.    632-3198   (SEPT

.1993)

DO NOT REMOVE THIS LABEL

326

COMPONENTS REQUIRED FOR INST

ALLA

TION:   6IN / 150MM ST

AINLESS STEEL

 LINER. ST

ANDARD 

ADAPT

OR (171-932) OR OFFSET 

ADAPT

OR (171-936)  

OPTIONAL

 COMPONENT

: F

AN (170-915), ELECTRICAL

 RA

TING: VOL

TS 1

1

5, 60 HZ, 0.6 

AMPS, SCREEN DOOR (846-101)

DO NOT REMOVE BRICKS OR MORT

AR IN MASONR

Y

 FIREPLACE.  FOR USE WITH SOLID WOOD FUEL

 ONL

Y

.  DO NOT USE GRA

TE 

OR ELEV

A

T

E FIRE.  BUILD WOOD FIRE DIRECTL

Y

 ON HEARTH.  OPERA

TE WITH FEED DOOR CLOSED, OPEN T

O

 FEED FIRE ONL

Y

.  

REPLACE GLASS ONL

Y

 WITH CERAMIC GLASS (5MM).  INSPECT 

AND CLEAN CHIMNEY

 FREQUENTL

Y

.   UNDER CERT

A

IN CONDITIONS 

OF USE CREOSOTE BUILDUP

 MA

Y

 OCCUR RAPIDL

Y

.  DO NOT OVERFIRE, IF INSERT GLOWS 

YOU 

ARE OVER-FIRING.

MINIMUM CLEARANCES T

O

 COMBUSTIBLE MA

TERIALS  (MEASURED FROM INSERT BODY)

INST

ALL

 ONL

Y

 ON 

A

 NON-COMBUSTIBLE HEARTH RAISED (F) 1.5IN / 38MM 

ABOVE 

AN 

ADJACENT COMBUSTIBLE FLOOR.  COMBUSTIBLE FLOOR 

MUST BE PROTECTED BY

 NON-COMBUSTIBLE MA

TERIAL

 EXTENDING 

(E) 16 IN / 405MM T

O

  FRONT 

AND (G) 8IN / 205MM T

O

 SIDES FROM FUEL

 

DOOR.

918-666

MANUF

ACTURED BY

:

FPI FIREPLACE PRODUCTS 

INTERNA

TIONAL

 L

TD.

6988 VENTURE ST

.

DEL

T

A,  BC    V4G 1H4

HOT WHILE IN OPERA

TION 

DO NOT T

OUCH.  KEEP

 CHILDREN, 

CLOTHING AND 

FURNITURE A

W

A

Y

 

CONT

ACT MA

Y

 CAUSE SKIN BURNS. 

  

READ ABOVE 

INSTRUCTIONS.

CAUTION

ADJACENT SIDEW

ALL

 

A) 

15in / 380mm

MANTLE 

B) 

20in / 510mm

T

O

P

 F

A

CING 

14in / 355 mm

SIDE F

A

CING 

D) 

7.375in / 185mm

INST

ALL

 AND USE ONL

Y

 IN 

ACCORDANCE WITH THE MANUF

ACTURER'S INST

ALLA

TION 

AND OPERA

TING INSTRUCTIONS.  INST

ALL

 AND USE ONL

Y

IN MASONR

Y

 FIREPLACE OR F

ACT

OR

Y

 BUIL

T FIREPLACE.

CONT

ACT LOCAL

 BUILDING OR FIRE OFFICIALS 

ABOUT RESTRICTIONS 

AND INST

ALLA

TION INSPECTION IN 

YOUR 

AREA.

UNITED ST

A

TES ENVIRONMENT

AL

  PROTECTION 

 

AGENCY

 CERTIFIED T

O

 COMPL

Y

 WITH JUL

Y

 1990, 

P

A

RTICULA

TE EMISSION ST

ANDARDS.

 

 JAN 

 FEB 

 MAR 

APR 

MA

Y

 

JUN 

JUL

 

AUG 

SEPT 

OCT 

NOV  

DEC

2007

2008

2009

(Duplicate Serial #)

DA

TE OF MANUF

ACTURE

MADE IN CANADA

326

NOTE: 

 Regency units are constantly being 

improved.  Check the label on the unit and if 
there is a difference, the label on the unit is 
the correct one.

Содержание I1200S Wood Insert

Страница 1: ...Canada V4G 1H4 918 665a I1200S Wood Insert 07 12 07 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Plea...

Страница 2: ...REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not properly installed a house re may result For your safety follow the installation instructions contact loc...

Страница 3: ...ation into a Masonry Fireplace 10 Installation into a Factory Built Fireplace 10 Faceplate Trim Optional Fan Support Installation 11 Fan Blower 14 Firebrick Assembly 15 Draft Control 15 Door Handle 15...

Страница 4: ...FROM INSERT BODY INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 1 5IN 38MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR COMBUSTIBLE FLOOR MUST BE PROTECTED BY NON COMBUSTIBLE MATERIAL EXTENDING E 16 IN 405M...

Страница 5: ...I1200 Regency Wood Insert 5 UNIT DIMENSIONS WITH STANDARD FLUE ADAPTOR 6 152mm Diameter STANDARD FLUE ADAPTOR 171 932...

Страница 6: ...I1200 Regency Wood Insert 6 UNIT DIMENSIONS WITH OFFSET FLUE ADAPTOR 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936...

Страница 7: ...your replace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Build ing Inspection Department You may require a...

Страница 8: ...508mm 14 356mm 7 375 187mm 16 406mm 1 5 38mm 8 203mm HOW TO DETERMINE IF ALTERNATE FLOOR PROTECTION MATERIALS ARE ACCEPTABLE The speci ed oor protector should be 3 8 18mm thick material with a K facto...

Страница 9: ...rear of the unit into the replace See diagram 3 Ensure that the unit is centered in the existing replace and lined up with the ue adaptor 4 Slide the unit back until the ue adaptor is slightly engage...

Страница 10: ...EPLACE The insert must be installed as per the require ments of your local inspection authority Three methods of ue connection are acceptable in most areas these include 1 Positive ue connection where...

Страница 11: ...ded See Diagram 2 Diagram 2 Rear View 4 Position the assembled faceplate side and top to the insert Ensure to align the draft rod into the opening of the faceplate as well as the side faceplate slots...

Страница 12: ...mounting brackets and tighten to secure in place Diagram 5 Diagram 6 Shown with Optional Bottom Faceplate Regular Oversize Faceplate Trim Installation Black Trim included with Regular Oversize Facepl...

Страница 13: ...on the fan support to the bottom of the fan assembly 17 Drill 4 x 5 32 holes to the underside of the fan assembly using the holes in the fan support as a guide See Diagram 9 Diagram 9 Rear Bottom View...

Страница 14: ...placemaybeadjustedby increasing or decreasing the offset spacing of the clips 3 Ensure that the power cord is not in contact with any hot stove surfaces CAUTION Label all wires prior to disconnection...

Страница 15: ...If the two air tubes are installed continue on to Step 2 if not follow the instructions below Installtheairtubeintotheholesinthe side channels The notch goes on the right hand side with the air holes...

Страница 16: ...he re As you dry out your re brick and your masonry ue if applicable your draft will increase 10 Forthoseunitsinstalledathigherelevations or into sub standard masonry replaces drafting problems may oc...

Страница 17: ...lly operate the fan system push the rst switch to Man and second switch to either high or Low This will bypass the sensing deviceandallowfullcontrolofthefan Switching from Auto to Manual or High to Lo...

Страница 18: ...acer washer shown in the diagram below will allow the latch to be moved closer to the door frame causing a tighter seal Remove and replace the nuts washer as shown MAINTENANCE GLASS CLEANING Do not at...

Страница 19: ...y Door Gasket Kit 17 846 918 Hinge Caps 2 set Gold 19 948 101 Spring Handle Large Gold 20 948 102 Spring Handle Small Gold 170 915 Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Co...

Страница 20: ...aceplate Trim Set Oversize Black 171 926 Trim Set Oversize Brass 171 928 Bottom Piece and Fan Support Regular 171 930 Bottom Piece and Fan Support Oversize 60 Faceplate Right Side Regular Oversize 61...

Страница 21: ...Description 170 960 Complete Brick Set 70 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 76 Brick Partial 1 1 4 x 2 x 9 81 Brick Partial 1 1 4 x 1 1 4 x 9 84 Brick Partial 1 1 4 x 4 1 2 x 8 85 Brick Partia...

Страница 22: ...I1200 Regency Wood Insert 22 NOTES...

Страница 23: ...of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by...

Страница 24: ...___________________________________________________ Printed in Canada Regency replace products are designed with reliability and simplicity in mind In addition our internal QualityAssurance Teamcarefu...

Отзывы: