26
Regency Horizon HZ54EPV Gas Fireplace
INSTALLATION
ELECTRICAL INSTALLATION
Note:
For ease of installation, the electrical installation must be completed
prior to adding any fi nishing materials.
1)
Remove faceplate, inner door frame and glass door (if installed)- refer to
instructions in this manual.
2)
Remove control board located on the lower right side of the unit,by
sliding board out as shown below.
5)
Loosen 2 screws - one on either side of the electrical box. Slide box up
and push box back to release.
6)
Manoeuvre and angle electrical box to remove from the base of the unit.
7)
Install strain relief grommets into opening in electrical box as shown
below.
3)
Locate wiring harness from Power Vent Module - shown below.
4)
Remove access panel - located on the outer right side of the unit, by
removing 4 screws in locations shown below.
Wiring harness from
Power Vent Module
Access panel
Power Vent Module
WARNING
THIS INSTALLATION SHOULD ONLY BE CARRIED
OUT BY A QUALIFIED AND LICENSED ELECTRICIAN
Electrical
Box
(Right side of
Unit)
8)
Unravel BX cable to reveal wires - install wire protector where the metal
of the BX cable meets the wire.
Wire protector
Strain relief grommet