24
Regency Horizon HZ54EPV Gas Fireplace
INSTALLATION
8
) Reattach the plate to the inside of the Power Vent outer frame with 2
screws from step 3.
9
) Feed the BX cable through the opening in the power vent terminal -
located in the lower left corner as shown below.
10
) Secure the terminal to the outer frame with 4 screws - screw locations
shown below.
12
) Tighten bolt to secure ground wire.
13
) Connect all like colored wires - red to red, blue to blue, black to black
and white to white. Place marettes on all paired wire ends (supplied
with kit)
14
) Place cable tie guides in holes located on the base of the terminal.
Feed cable tie through the guide.
15
) Tie down all wires with cable ties - away from the
edge of the terminal base and fan blade.
11
) From the wire bundle (from BX cable) secure the copper ground to the
ground lug on the right side.
Important:
Ground must be wrapped under star washer - prior to
tightening.
Star washer
Cable tie guide
Marettes
Cable tie