14
Regency Horizon HZ54EPV Gas Fireplace
INSTALLATION
A
B
C
D
E
F
G
H
I
J
K L
Non-Combustible
Facing
Metal Stud (Header)
on edge
Metal Stud
(Header)
on edge
(Located on the right side of the fireplace)
Framing
Dimensions
Description
HZ54EPV
A
Framing Height
46-5/8” (1184mm)
B
Framing Width
60” (1524mm)
B1 (see next page)
Framing Width (negative vent run)
70" (1778mm)
B2 (see next page)
Framing Width (negative vent run)
80" (2032mm)
C
*
Framing Depth
*
22” (559mm)
C1
*
(see next page)
Framing Depth
*
(negative vent run)
31” (787mm)
D
Minimum Height to Combustibles
51” (1295mm)
E
Corner Wall Depth
72" (1829mm)
F
Corner Facing Wall Width
101-7/8 (2586mm)
G
Vent Centerline Height
44” (1118mm)
H
Non-combustible facing height
20” (508mm)
I
Gas Connection Opening Height
1-1/2” (38mm)
J
Gas Connection Height
4” (102mm)
K
Gas Connection Inset
7-1/4” (184mm)
L
Gas Connection Opening Width
3-1/4” (83mm)
*
Framing depth measurement is noted with the side nailing strips set as far forward on the fi rebox as possible.
The side nailing strips can be adjusted back up to 1” to allow for varying thicknesses in non-combustible material
& wall fi nishes.
Important:
The minimum framing dimensions given for height, width and depth must be maintained even if using
non combustible materials.
Dangerous operating conditions will occur if minimum framing dimensions are not adhered to.
FRAMING DIMENSIONS