background image

Regency Wood Insert & Hearth Heater

10

Ground

Fan

Fan

Ground

Green

Neutral

Live

White

Fan

Switch

Manual/

Auto

Switch

Black

Black

High

(Black)

Low

(Red)

Black

Fan Thermodisc

(normally open)

120V AC

60 Hz

Thermo

Switch

Sensor

Thermo

Switch

Sensor

INSTALLATION

FAN / BLOWER

Blower/Fan Wiring Diagram

3)

  Slide the supports into the clips. The tension 

holding the clips in place may be adjusted by 
increasing or decreasing the offset spacing 
of the clips.

4)

  Ensure that the power cord is not in contact 

with any hot stove surfaces.

 

 

5)

  Push the Regency logo plate into the two 

holes in the front bottom left corner of the 
fan.

Your fan should only be installed once the unit is 
in place in order to prevent any damage to the 
fan. To attach, follow the instructions provided 
with the fan. Make sure to install the rubber 
grommet to the fan housing before it is installed 
on the insert.  

1)

  Remove the protective covering from the 

brass trim on the fan.

2)

  Align the fan support with the offset clip on 

the bottom of the ashlip. 

CAUTION:   Label all wires prior 
to disconnection when servic-
ing controls. Wiring errors can 
cause improper and dangerous 
operation.

WARNING: 

Electrical Grounding Instructions

This appliance is equipped with a 
three pronged (grounding) plug for 
your protection against shock hazard 
and should be plugged directly into 
a properly grounded three-prong 
receptacle. Do not cut or remove the 
grounding prong from this plug.

Do not turn fan ON until your insert has 
reached operating temperature or at least 
30 minutes after starting fi re.

f i r e - p a r t s . c o m

Содержание H2100

Страница 1: ... H2100 I1100S I3100L WOOD Fireplace Inserts Hearth Heater 11 15 07 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com fire parts com ...

Страница 2: ...ave any questions about your product that are not covered in this manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact local building or fire officials about restrictions and instal lation inspection requirements in your area fire ...

Страница 3: ...y Built Fireplace 8 Installation Into a Masonry Fireplace 8 Faceplate and Trim 9 Fan Blower 10 Floor Protection 11 Firebrick Assembly 11 Door Handle 11 Brick Flue Baffle Secondary Air Tube Installation 11 Draft Control 12 Screen Door 12 OPERATING INSTRUCTIONS First Fire 13 Fan Operation All Units 13 Ash Disposal 13 Some Safety Guidelines 13 Creosote 14 MAINTENANCE Maintenance of Gold Plated Doors 1...

Страница 4: ...tents here for your review LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U S A MODEL I1100S TESTED TO ULC S628 M93 UL 1482 1998 ULC S627 00 UL 737 2000 REPORT NO 632 3198 SEPT 1993 DO NOT REMOVE THIS LABEL 104 A G F D B C E ADJ AC ENT S IDEWAL L COMPONENTS REQUIRED FOR INSTALLATION 6IN 150MM STAINLESS STEEL LINER OPTIONAL COMPONENT FAN ELECTRICAL RATING VOLTS 115 60 HZ 0 6 ...

Страница 5: ...E FACING D 8 5 in 216mm HEARTH EXTENSION DEPTH E 18 in 455 mm HEARTH EXTENSION ELEVATION F 1 5 in 38 mm HEARTH EXTENSION WIDTH G 6 in 150 mm A G F D B C E ADJ AC ENT S I D EWAL L INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 1 5 IN 38 MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR COMBUSTIBLE FLOOR MUST BE PRO TECTED BY NON COMBUSTIBLE MATERIAL EXTENDING E 18 IN 455 MM TO FRONT AND G 6 IN 150 MM TO SI...

Страница 6: ...rer s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of unit 3 Notify your home...

Страница 7: ... Minimum Minimum Unit Side Wall to Top Facing Facing Hearth Hearth Hearth Side to Side to Top to Side Extension Thickness Extension A B C D E F G Small Flush Insert I1100S 15 380mm 20 510mm 14 355mm 7 375 187mm 16 406mm 1 5 38mm 8 205mm Large Flush Insert I3100L 13 330mm 19 480mm 18 455mm 6 5 165mm 16 406mm 1 5 38mm 8 205mm Hearth Heater H2100M 10 255mm 25 635 mm 14 355mm 8 5 216mm 18 455mm 1 5 38...

Страница 8: ...greaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glass INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built fireplace a full stainless steel rigid or flexible flue liner is mandatory for both safety and perform ance purposes When a flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created...

Страница 9: ...and faceplate trim withtheunitpulledslightlyawayfrom the fireplace face If this is done be very careful not to disturb the con nector when shifting the unit to its final position Now that your insert is installed check once more that all the clearances from the unit to any combustible materials are correct as listed earlier Diagram 1 I1100S 6 Once the above items have been checked slide your insert ...

Страница 10: ...er to prevent any damage to the fan To attach follow the instructions provided with the fan Make sure to install the rubber grommet to the fan housing before it is installed on the insert 1 Remove the protective covering from the brass trim on the fan 2 Align the fan support with the offset clip on the bottom of the ashlip CAUTION Label all wires prior to disconnection when servic ing controls Wir...

Страница 11: ...st Baffle Brick down and then slide the2ndBaffleBrickupandback Reposition both baffle bricks flat on the air tubes 3 Important push both baffle bricks so they are tight against the side walls 4 Install the third air tube into the holes on the side channels The notch goes on the right hand side with the air holes facing forward toward the door opening If the tube will not slide in easily simply use a pa...

Страница 12: ...rick flat on the air tube 4 Important push both baffle bricks so they are tight against the side walls Note When getting the chimney cleaned remove the baffle bricks for access to the flue then replace them when cleaning is completed Lift the rear of the baffle pivoting it on the air tube until it clears the rear air channel Slide the rear of the baffle on top of the rear air channel in front of the loc...

Страница 13: ...l WARNING Never build a roaring fire in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established you may adjust the draft control to a low settingtooperatetheunitinitsmostefficient mode 6 During the first couple of hours keep the combustion rate at a moderate level and avoid a large fire until the paint is cured Only then can you operate the insert at its maximum settin...

Страница 14: ...insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits within the heating system 2 Burn insert with draft control wide open for about 10 15 minutes every time you add freshwood Thisallowsthewoodtoachieve the charcoal stage faster and burns up any wood vapors which might otherwise be deposited within the system 3 Onlyburnseaso...

Страница 15: ...dle Large 20 948 102 Spring Handle Small 23 820 235 Flue Brackets Pkg 163 915 I3100L Fan Blower Assembly 170 915 I1100S Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 063 954 Air Tube 1 I3100 Qty 1 074 954 Air Tube 1 I1100 Qty 1 3...

Страница 16: ...rim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Part Description Faceplate I1100S 170 911 Faceplate Trim Set Regular 185 170 160 Trim Right Regular 186 170 159 Trim Top Regular 187 170 162 Trim Left Regular 183 Faceplate Right Side Regular 188 Faceplate Left Side Regular 189 Faceplate Top Regular 170 913 Faceplate Trim Set Oversize 195 143 161 Trim Right Oversize 196 170 1...

Страница 17: ...s 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 212 Baffle Insulation 38 Insulation Weights 39 120 950 Steel Baffle 948 216 Regency Logo Faceplate H2100M 120 910 Faceplate Trim Set Regular 485 120 161 Trim Right Regular 286 143 158 Trim Top Regular 487 120 1...

Страница 18: ...802 104 Brick Partial 1 1 4 x 4 x 9 72 802 146 Brick Partial 1 1 4 x 1 3 4 x 9 75 802 139 Brick Partial 1 1 4 x 4 x 8 3 4 76 802 152 Brick Partial 1 1 4 x 2 x 9 78 802 143 Brick Partial 1 1 4 x 2 1 4 x 2 1 4 81 802 135 Brick Partial 1 1 4 x 1 1 4 x 9 84 802 107 Brick Partial 1 1 4 x 4 1 2 x 8 85 802 156 Brick Partial 1 1 4 x 4 1 4 x 8 fire parts com ...

Страница 19: ...of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts reques...

Страница 20: ...______________________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal QualityAssurance Teamcarefullyinspectseachunitthor oughly before it leaves our door FireplaceProductsInternational Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product See the inside back c...