background image

Regency Wood Insert & Hearth Heater

6

INSTALLATION

CHIMNEY 

SPECIFICATIONS

Before installing, check and clean your chimney 
system thoroughly. If in doubt about its condi-
tion, seek professional advice. Your Regency 
Insert is designed for installation into a masonry 
fi replace that is constructed in accordance with 
the requirements of "The Standard for Chimneys, 
Fireplaces, Vents, and Solid Fuel Burning Ap-
pliance", N.F.P.A. 211, the National Building 
Code of Canada, or the applicable local code 
requirements.  

The appliance, when installed, must be electri-
cally grounded in accordance with local codes or, 
in the absence of local codes, with the National 
Electrical Code, ANSI/NFPA 70, or the Canadian 
Electrical code, CSA C22.1.

Regency Inserts are designed with a 6" (152mm) 
fl ue.

Requirements for Installing 

Solid-fuel Inserts in Factory-built 

Fireplaces.

1)

  The insert must be tested and meet the 

requirements of UL 1482 (U.S.) and or ULC 
S628 (Canada) when tested in a masonry 
fi replace built per ULC S628.

2)

  The factory-built fi replace must be listed per 

UL 127 or ULC S610.

3)

  Clearances obtained from the masonry fi re-

place tests are also relevant for installation 
in factory-built fi replaces.

4)

  Installation must include a full height listed 

chimney liner type HT requirements (2100 
degree F.) per UL 1777 (U.S.) or ULC 
S635 (Canada). The liner must be securely 
attached to the insert fl ue collar and the 
chimney top.

5)

  Means must be provided to prevent room 

air passage to the chimney cavity of the 
fi replace. This may be accomplished by 
sealing the damper area around the chimney 
liner, or sealing the fi replace front.

6)

 Alteration 

of 

the 

fi replace in any manner is not 

permitted with the following exceptions; 

 

a. 

  external trim pieces which do not affect 

the operation of the fi replace may be 
removed providing they can be stored 
on or within the fi replace for re-assembly 
if the insert is removed.

 

b.

   the chimney damper may be removed 

to install the chimney liner.

7)

  Circulating air chambers (i.e. in a steel 

fi replace liner or metal heat circulator) shall 
not be blocked.

8)

  Means must be provided for removal of the 

insert to clean the chimney fl ue.

Regency Inserts are constructed with the high-
est quality materials and assembled under strict 
quality control procedures that insure years of 
trouble free and reliable performance.

It is important that you read this manual thor-
oughly and fully understand the safe instal-
lation and operating procedures.  The more 
you understand the way your Regency Insert 
operates, the more enjoyment you will experi-
ence from knowing that your unit is operating 
at peak performance.

BEFORE INSTALLING

YOUR INSERT

1)

  Read all instructions before installing and 

using your fi replace insert.  Install and use 
only in accordance with manufacturer’s 
installation and operating instructions.

2)

  Check your local building codes - Building 

Inspection Department.  You may require 
a permit before installing your insert. Be 
aware that local codes and regulations may 
override some items in the manual.

 

WARNING:  Careless installation is the 
major cause of safety hazard.  Check all 
local building and safety codes before 
installation of unit.

3)

  Notify your home insurance company that 

you plan to install a fi replace insert or hearth 
heater.

4) 

Your fi replace insert is heavy and requires 
two or more people to move it safely.  The 
insert can be badly damaged by mishan-
dling.

5)

  If your existing fi replace damper control 

will become inaccessible once you have 
installed your Regency Insert, you should 
either remove or secure it in the open posi-
tion.

6)

  Inspect your fi replace and chimney prior 

to installing your insert to determine that it 
is free from cracks, loose mortar or other 
signs of damage. If repairs are required, 
they should be completed before installing 
your insert.  Do not remove bricks or mortar 
from your masonry fi replace.

7)

  Do not connect the insert to a chimney 

system servicing another appliance or an 
air distribution duct.

9)

  Inserts that project in front of the fi replace 

must be supplied with appropriate supporting 
means.

10)

 Installer must mechanically attach the sup-

plied label to the inside of the fi rebox of the 
fi replace into which the insert is installed.

In order for a solid-fuel insert to be certifi ed 
for use in factory-built fi replaces, the above 
information must be clearly stated in the instal-
lation manual and appropriate markings. Final 
approval is contingent on the authority having 
jurisdiction.

FIREPLACE 

SPECIFICATIONS

Your fi replace opening requires the following 
minimum sizes:

                             Height         Width Depth
Small (I1100S) 

20" 

23"  13.25"

Large (I3100L) 

25" 

28" 

17"

Hearth Heater (H2100M) 20.0"  -- 

--

Two faceplates are available to seal the fi re-
place opening:
 

 

 Standard 

Oversize

Small (I1100S)
  36"W x 26"H                   39.875"W x 30"H

Large (I3100L)
  44"W x 32"H 

50"W x 34.5"H

Hearth Heater (H2100M)
  40 1/4"W x 30"H 

48"W x 33"H

INSTALLING YOUR 

INSERT

Your insert is very heavy and will require two 
or three people to move it into position. The 
insert can be made a little lighter by removing 
the cast iron door by opening it and lifting it 
off its hinges. Be sure to protect your hearth 
extension with a heavy blanket or carpet scrap 
during the installation.

Convection Grills for 

I3100L 

The convection grills are installed 

before

 the 

unit is positioned inside the fi replace.

Emissions from burning  wood or gas could 
contain chemicals known to the State of Cali-
fornia to  cause cancer, birth defects or other 
reproductive harm.

"

WARNING

: This fi replace has been converted 

for use with a wood insert only and cannot be 
used for burning wood or solid fuels unless 
all original parts have been replaced, and the 
fi replace re-approved by the authority having 
jurisdiction."

f i r e - p a r t s . c o m

Содержание H2100

Страница 1: ... H2100 I1100S I3100L WOOD Fireplace Inserts Hearth Heater 11 15 07 Owners Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www regency fire com fire parts com ...

Страница 2: ...ave any questions about your product that are not covered in this manual please contact the REGENCY DEALER in your area Keep those REGENCY FIRES burning SAFETY NOTE If this Insert is not properly installed a house fire may result For your safety follow the installation instructions contact local building or fire officials about restrictions and instal lation inspection requirements in your area fire ...

Страница 3: ...y Built Fireplace 8 Installation Into a Masonry Fireplace 8 Faceplate and Trim 9 Fan Blower 10 Floor Protection 11 Firebrick Assembly 11 Door Handle 11 Brick Flue Baffle Secondary Air Tube Installation 11 Draft Control 12 Screen Door 12 OPERATING INSTRUCTIONS First Fire 13 Fan Operation All Units 13 Ash Disposal 13 Some Safety Guidelines 13 Creosote 14 MAINTENANCE Maintenance of Gold Plated Doors 1...

Страница 4: ...tents here for your review LISTED FACTORY BUILT FIREPLACE INSERT CERTIFIED FOR USE IN CANADA AND U S A MODEL I1100S TESTED TO ULC S628 M93 UL 1482 1998 ULC S627 00 UL 737 2000 REPORT NO 632 3198 SEPT 1993 DO NOT REMOVE THIS LABEL 104 A G F D B C E ADJ AC ENT S IDEWAL L COMPONENTS REQUIRED FOR INSTALLATION 6IN 150MM STAINLESS STEEL LINER OPTIONAL COMPONENT FAN ELECTRICAL RATING VOLTS 115 60 HZ 0 6 ...

Страница 5: ...E FACING D 8 5 in 216mm HEARTH EXTENSION DEPTH E 18 in 455 mm HEARTH EXTENSION ELEVATION F 1 5 in 38 mm HEARTH EXTENSION WIDTH G 6 in 150 mm A G F D B C E ADJ AC ENT S I D EWAL L INSTALL ONLY ON A NON COMBUSTIBLE HEARTH RAISED F 1 5 IN 38 MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR COMBUSTIBLE FLOOR MUST BE PRO TECTED BY NON COMBUSTIBLE MATERIAL EXTENDING E 18 IN 455 MM TO FRONT AND G 6 IN 150 MM TO SI...

Страница 6: ...rer s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless installation is the major cause of safety hazard Check all local building and safety codes before installation of unit 3 Notify your home...

Страница 7: ... Minimum Minimum Unit Side Wall to Top Facing Facing Hearth Hearth Hearth Side to Side to Top to Side Extension Thickness Extension A B C D E F G Small Flush Insert I1100S 15 380mm 20 510mm 14 355mm 7 375 187mm 16 406mm 1 5 38mm 8 205mm Large Flush Insert I3100L 13 330mm 19 480mm 18 455mm 6 5 165mm 16 406mm 1 5 38mm 8 205mm Hearth Heater H2100M 10 255mm 25 635 mm 14 355mm 8 5 216mm 18 455mm 1 5 38...

Страница 8: ...greaterdraftcan decrease problems such as difficult start ups smoking out the door and dirty glass INSTALLATION INTO A FACTORY BUILT FIREPLACE 1 When installed in a factory built fireplace a full stainless steel rigid or flexible flue liner is mandatory for both safety and perform ance purposes When a flue or liner is in use the insert is able to breathe better by allowing a greater draft to be created...

Страница 9: ...and faceplate trim withtheunitpulledslightlyawayfrom the fireplace face If this is done be very careful not to disturb the con nector when shifting the unit to its final position Now that your insert is installed check once more that all the clearances from the unit to any combustible materials are correct as listed earlier Diagram 1 I1100S 6 Once the above items have been checked slide your insert ...

Страница 10: ...er to prevent any damage to the fan To attach follow the instructions provided with the fan Make sure to install the rubber grommet to the fan housing before it is installed on the insert 1 Remove the protective covering from the brass trim on the fan 2 Align the fan support with the offset clip on the bottom of the ashlip CAUTION Label all wires prior to disconnection when servic ing controls Wir...

Страница 11: ...st Baffle Brick down and then slide the2ndBaffleBrickupandback Reposition both baffle bricks flat on the air tubes 3 Important push both baffle bricks so they are tight against the side walls 4 Install the third air tube into the holes on the side channels The notch goes on the right hand side with the air holes facing forward toward the door opening If the tube will not slide in easily simply use a pa...

Страница 12: ...rick flat on the air tube 4 Important push both baffle bricks so they are tight against the side walls Note When getting the chimney cleaned remove the baffle bricks for access to the flue then replace them when cleaning is completed Lift the rear of the baffle pivoting it on the air tube until it clears the rear air channel Slide the rear of the baffle on top of the rear air channel in front of the loc...

Страница 13: ...l WARNING Never build a roaring fire in a cold stove Always warm your stove up slowly 5 Once a bed of coals has been established you may adjust the draft control to a low settingtooperatetheunitinitsmostefficient mode 6 During the first couple of hours keep the combustion rate at a moderate level and avoid a large fire until the paint is cured Only then can you operate the insert at its maximum settin...

Страница 14: ...insert with draft control wide open for about15minuteseverymorningduringburn ing season This helps to prevent creosote deposits within the heating system 2 Burn insert with draft control wide open for about 10 15 minutes every time you add freshwood Thisallowsthewoodtoachieve the charcoal stage faster and burns up any wood vapors which might otherwise be deposited within the system 3 Onlyburnseaso...

Страница 15: ...dle Large 20 948 102 Spring Handle Small 23 820 235 Flue Brackets Pkg 163 915 I3100L Fan Blower Assembly 170 915 I1100S Fan Blower Assembly 24 910 157 P Blower Fan Motor 25 910 678 Power Cord 120 Volts 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 063 954 Air Tube 1 I3100 Qty 1 074 954 Air Tube 1 I1100 Qty 1 3...

Страница 16: ...rim Left Oversize 398 Faceplate Side Oversize 399 Faceplate Top Oversize Part Description Faceplate I1100S 170 911 Faceplate Trim Set Regular 185 170 160 Trim Right Regular 186 170 159 Trim Top Regular 187 170 162 Trim Left Regular 183 Faceplate Right Side Regular 188 Faceplate Left Side Regular 189 Faceplate Top Regular 170 913 Faceplate Trim Set Oversize 195 143 161 Trim Right Oversize 196 170 1...

Страница 17: ...s 27 910 142 Fan Thermodisc 28 910 140 Fan Speed Switch HI OFF LOW 3 way 29 910 138 Switch Auto Manual 2 way 30 Grommet Strain Relief 35 120 954 Air Tube Front 36 120 953 Air Tube Rear 37 836 212 Baffle Insulation 38 Insulation Weights 39 120 950 Steel Baffle 948 216 Regency Logo Faceplate H2100M 120 910 Faceplate Trim Set Regular 485 120 161 Trim Right Regular 286 143 158 Trim Top Regular 487 120 1...

Страница 18: ...802 104 Brick Partial 1 1 4 x 4 x 9 72 802 146 Brick Partial 1 1 4 x 1 3 4 x 9 75 802 139 Brick Partial 1 1 4 x 4 x 8 3 4 76 802 152 Brick Partial 1 1 4 x 2 x 9 78 802 143 Brick Partial 1 1 4 x 2 1 4 x 2 1 4 81 802 135 Brick Partial 1 1 4 x 1 1 4 x 9 84 802 107 Brick Partial 1 1 4 x 4 1 2 x 8 85 802 156 Brick Partial 1 1 4 x 4 1 4 x 8 fire parts com ...

Страница 19: ...of workmanship from unauthorized service persons or dealers At all times FPI reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to FPI by authorized selling dealers It is essential that all submitted claims provide all of the necessary information including customer name purchase date serial type of unit problem and part or parts reques...

Страница 20: ...______________________________________ Printed in Canada Regency fireplace products are designed with reliability and simplicity in mind In addition our internal QualityAssurance Teamcarefullyinspectseachunitthor oughly before it leaves our door FireplaceProductsInternational Ltd is pleased to extend this Limited Lifetime Warranty to the original purchaser of a Regency Product See the inside back c...

Отзывы: