12
Regency GFi350L Gas Fireplace Inbuilt
installation
ZERO CLEARANCE BOX INSTALLATION
919-811
07.06.17
1
GFI350L
ZERO CLEARANCE BOX INSTALLATION
1. Remove the flue collar from the zero clearance box by removing 4 screws
in locations shown below. Install the flex pipe, onto the lower collar and
secure with provided clamp.
Note:
Determine the thickness of the finishing material before securing the
flue collar to the box. Using the front set of holes to secure the flue
collar will allow an extra 25mm of clearance for thicker materials.
tooltip
tooltip
tooltip
tooltip
tooltip
2. Slide the box into the framed opening, secure the box to the framing with
4 screws on each side.
3. Remove the flue collar assembly from the unit by sliding the collar away
from the unit--and recycle the part.
4. Attach the new flue collar assembly from the zero clearance box (Part No:
627-522) and attach it to the flex pipe using sealant and clamp provided
as in the previous step.
5. Compress the flex pipe with attached flue assembly to allow clearance for
the unit.
6. Slide the unit into place while guiding the unit flue assembly back into
position on top of the unit and secure.
Use front holes for thicker finishing materials.
Flue Collar
Note:
Apply the sealant provided
around the perimeter of the flue
collar prior to joining the two
parts together with the clamp.
Part #: 627-522